Att be om hjälp utan att fråga
This report is our Master thesis. Our work has taken place at a one-stop-shop in Sölvesborg during the spring of 2002. We have conducted ethnographical studies concerning the one-stop-shops frontdesk and telephone exchange. During these studies we became aware of some differences under which the daily work was to be carried out. When operating the switchboard the staff usually work alone and perform the tasks individually.
Undersökningsmetodik för klorerade lösningsmedel i marken
Chlorinated solvent are volatile organic substances that can be harmful for humans and for the environment. Examples of common chlorinated solvents are perchloroethene, PCE, and trichloroethene, TCE. Chlorinated solvents appear as contaminants in soils primarily where they have been used as washing fluids in dry-cleaning facilities or as degreasers in metal industries. Chlorinated solvents are DNAPLs (dense non-aqueous phase liquids), which means that they are not easily dissolved in water and that they sink to the bottom of the aquifer. Adsorption to soils is low so chlorinated solvents are mobile in soils.
Förekomst av törskate (Cronartium flaccidum, Peridermium pini) på tall (Pinus sylvestris) i relation till markfuktighet och fältskikt : en studie om 2000-talets törskateepidemi i norra Sverige
Resin-top disease is a rust fungi that occurs both as a host alternating form, Cronartium flaccidum G. Winter., and as a non-host alternating form, Peridermium pini Pers. The host alternating form can use a variety of hosts but the most commonly used species in the boreal forest is Melampyrum sylvaticum. In Scandinavia the Resin-top disease infect Scots pine, Pinus sylvestris L. The fungus infects the needles through the stomata and then grows through the branch to the stem where it strangulates the vessels transporting water and nutrition to the treetop, which kills the top.
Inventering av Maskinisten 6 och Valhall 2 på LEAX fastigheter i Köping enligt MIFO fas 1
This study is a degree project in environmental engineering at Mälardalens university. Its purpose has been to perform a risk assessment on whether or not any contaminations are present in the soil at two properties in Köping. The assessment was to be done accordingly to a method that has been set up by The Swedish Environmental Protection Agency (Naturvårdsverket). The method for investigation of contaminated sites is called MIFO. MIFO consists of two stages.
Samverkanspelare i icke bärande fasadelement
AbstractThe tests work is about the subject "synergism of steel and concrete."The construction sector is in a strong competition and the different companies in the PrefabMarket has ever tried to develop new design solutions that are efficient and environmentallyfriendly.The purpose of this report is to highlight different aspects of interaction and size up a columndimension and to examine its efficiency and load capacity as Eurocode 3 and Eurocode 4. A sizing chart that describes the relationship between the torque and normal force shouldalso be made of the interaction . .
Modellerade och uppmätta kväveflöden i energiskog som bevattnas med avloppsvatten
The aim of this essay was to study the nitrogen flow in two willowplantations, at different locations in the south of Sweden, that wereirrigated with sewage. The study was also performed to compare thedifferences in nitrogen flows between two years, 1998 and 1999. The studywas made in three parts. First, the denitrification activity was measuredusing the acetylen inhibition method. Second the nitrogen flow, as well asthe water- and heat flows, were modeled through the SOIL-SOILN-modelThird; the nitrogen flow was calculated to compare with the results fromthe model.The results from the measurements were then compared with the resultsfrom the SOILN-simulations to detect differences in the denitrificationrate.
Vinterträdgårdar ur ett byggperspektiv : En undersökning om byggandet av vinterträdgårdar
The purpose of this of this essay is to explore the construction of a conservatory that is livable allyear around. When you build a conservatory there are several factors that need to be regardedthat usually are of no importance when you build a regular conservatory. The glassed facadeneeds to have a very good U-value and all the parts of the facade need to be isolated and theconstruction needs to prevent thermal bridges.In this essay we will start by looking at the shape of the conservatory. Due to the façade consistsof glass the conservatory will need to have a good ratio between the area and the façade so thatthe heat losses will be at a minimum. However, due to the fact that one of the sides of the façadeis connected to the warm house, you quickly realize that the shape of the conservatory is of noimportance.There are two common ways to build a foundation for a conservatory, a molded concretefoundation and isolated wooden beams.
Short-term responses of the field layer vegetation in a south Swedish deciduous forest after establishment of wild boars (Sus scrofa)
Inside the south Swedish national park Dalby Söderskog, wild boars (Sus scrofa L.) have been visiting since 2010. The presence of wild boars has earlier been proven to
impact both soil and vegetation characteristics, both positively and negatively. Still, there is a lack of knowledge regarding the rooting effect on the vegetation in
deciduous forest within the native range. In this study, I have compared the field vegetation collected before and after the invasion of wild boars in 74 permanent experimental plots. More specifically, the study aimed to qualify the effect of wild boar rooting on cover ratio, species richness and species composition in a temperate
deciduous forest.
Historiska emissioner av bly och arsenik till luft från Åfors Glasbruk och deras konsekvenser för miljön.
Åfors glasswork was a company which started in 1876 and closed in 2012 due to the bad economical situation in the company. After its closure, the glasswork left behind contaminated soil with different concentrations of heavy metals such as, arsenic from arsenic trioxide, a chemical used to remove bubbles during the melting of glass, and lead oxide, a chemical used in the production of crystal glass. Crystal glass?s production occurred under 1921-1971, but emissions of lead into the air from Åfors glasswork continued until 2011, because of the artist Bertil Valliens? artglas was made in Åfors glasswork from 1970?s and onwards.The aim of this study was to estimate how much lead (Pb) and arsenic (As) that were released by Åfors Glasswork into the atmosphere during the operational period of the glasswork in comparison with how much of lead and arsenic were purchased for the company. Added to the assistance of the data from National Archives the variations in the activities of Åfors glasswork could be shown.
Husproduktion, kritiska skeden i produktion
As a newly graduated student in construction you rarely have as much knowledge as you wish you had. It is a complicated line of business that requires knowledge and understanding of both technical solutions and interaction between actors. It is impossible to be fully learned and with that much unknown it can be hard to know where to start. This report is one step in the right direction. It contains a planning that contains construction and installations for a one level house in Kiruna with its different choices motivated.
Temperatursprickor i ung betong : Utvärdering av projektering och utförande av åtgärder, samt utveckling av dimensioneringsmetod för kylsystem
The report contains three parts. The first part is a summary and overall presentation of thermalcracks and preventing measures against such cracks. This is a theoretical part where theinterested designer can get acquainted with various alternatives, be guided to more detailedliterature, and receive some practical information regarding the design of the respectivemeasures.The second part deals with calculation of the risk for thermal cracks and design of water coolingas a limiting measure. Two complementary methods are reviewed for efficient calculation:?the handbook method CraX1(by Lulea University of Technology) is used for quickverification?finite differential analysis in the calculationtool ConTeSt Pro for more precise projectingHere is also presented a development of existing standards through design of the cooling systemby means of the Bernoulli equation.
Köldbryggor och energiförluster. En studie om energiförluster genom balkonginfästningar och deras betydelse för byggnadens totala energibehov
In this report the balconies? abutments for a property in Bo01-area in Malmö has been studied. The property which is called Vitruvius contains four build-ings where two of them have corbelling balconies with intermittent abutments. With intermittent abutment means that the 50 mm thermal bridge insulation that the balconies is equipped with, is broken regularly by a 300 mm concrete heel. The reinforcement bar that holds the balcony runs through this heel.
Kvalitetssäkring av markberednings- och planteringsuppföljning hos SCA Skog AB Jämtlands skogsförvaltning :
Quality assurance means to systematically work for better understanding of the customers needs, demands and expectations. The goal for this study was to investigate how quality can be assured in the job follow up that is made by forestry contractors after soil scarification and planting. The study consisted of a description over the current follow up process at SCA forest AB Jämtlands forest administration, analysis of current follow up situation and an investigation of follow up process made by contractors in other line of business.
The first step was a statistical comparison where the own follow up made by contractors were compared with follow up made by SCA them selves over 100 stands. Two soil scarification contractors and two planting contractors carried out the silvicultural measures. The results showed that significant differences between a number of quality factors measured, for example number of approved plants or approved scarification points, average score on stand and number of totally planted plants.
Anlockning och gnag av snytbaggar (Hylobius sp.) : effekt av plantstorlek och behandling med metyljasmonat
Two field experiments were conducted in central Sweden in order to: 1) Determine a relationship between the number of approaching pine weevils (Hylobius sp.) and the number of attacks by pine weevils, in relation to the size of seedlings of Scots pine (Pinus sylvestris). 2) Determine if application of methyljasmonate (MJ) on seedlings of Scots pine will result in higher resistance towards attacks by pine weevils and/or have any effect on the number of approaching pine weevils. The field experiments were designed with two separate parts in close vicinity on the same clear cuttings: a) pitfall traps placed in patches of scarified soil that caught approaching pine weevils at 2.5 cm from the bait, which consisted of different sized seedlings of Scots pine some of which were subjected to application of MJ and b) the same type of seedlings planted out in patches of scarified soil.
The first field experiment was conducted on a 1-year old clear cutting outside Uppsala in east central Sweden and the trapping part of the experiment consisted of 8 blocks with 6 treatments: 1) control, 2) small over-wintered seedling, 3) medium sized seedling, 4) medium sized seedling treated with 0.5 ml 100 mmol MJ 4 days prior to start of experiment, 5) large seedling, 6) vial with 9.5 ml of ?-pinene. The trapping experiment lasted for 6 weeks in the early summer.
Föroreningstransport i grundvatten : En modelljämförelse
This thesis compares different methods for risk assessment of a creosote contaminated site in Vansbro, Dalarna. In a complementary study the importance of using representative data for calibration and validation of stationary groundwater models is discussed. The time dependency between surface water levels and groundwater levels on the site in Vansbro is evaluated by step response analysis. The results show that the groundwater levels reflect only long-term variation in the surface water levels. Hence the use of such long-term means for calibration and validation of the stationary groundwater models is the only theoretically defendable alternative.As a first step in the comparison of risk assessment methods the degree of contamination is evaluated on the basis of generic guideline values for contaminated soils, developed by the Swedish Environmental Protection Agency.