Översyn av uppvärmning

The heating of companies premises is today functional with electrical heating and heating offossil fuel. The energy cost for these kinds of heating in buildings has heavily increased duringthe last years and the influence on the environment has become more visual. This leads to thatenterprises today become more anxious to render energy more effective and find alternativesolutions to their ancient heating systems. This is something that Skandinaviska kraftprodukterAB in Halmstad has become aware of.The purpose with this examination is to find the most cost-efficient and environmental measuresfor the office and workshop premises of SKP AB. Where one of the bigger things is to find agood alternative for their current oil furnace, which was heating the workshop.

Effektivare elanvändning på avfallskraftvärmeverk : Förslag till handlingsplan för minskad elanvändning på Renovas anläggning i Göteborg

This thesis has identified and studied measures to allow for reduced use of electricity in a waste incineration plant in western Sweden. The energy extracted from the waste at the powerplant is utilized and sold in form of electricity and heat. Technical and environmentally the combined heat and power plant is by today's standards among the leading waste incineration plants in the world. The owners are constantly striving to improve the efficiency of the waste incineration plant. They have seen the opportunities for savings in reducing internal usage of electricity.

Interorganisatoriska Samarbeten : Struktur och Styrning för Lärande och Kunskapsspridning

Bakgrund: I och med den fokusering på kärnkompetenser som idag råder krävs det att organisationer besitter en god samarbetsförmåga. För att denna förmåga skall kunna utvecklas krävs det att det finns förutsättningar för lärande och kunskapsspridning i gränssnittet mellan organisationerna. Syftet: Syftet är att undersöka hur organisationer, genom organisationsstruktur samt styrning, internt kan skapa förutsättningar för lärande och kunskapsspridning i interorganisatoriska samarbeten. Genomförande: Vår undersökning är en hermeneutisk undersökning av fallstudiekaraktär. Två fallföretag har använts, BT Products och Sapa Profiles, där vi studerat inköps- respektive säljavdelningen.

Inventering av processvattenbalans : fastställande av fjärrvärmedistributionens läckage inom Vattenfall Värme Uppsala AB

Heat is distributed to the district heating customers through pipes with water as a heat carrier. The district heating system is complex. To decide what is leakages from the district heating net versus what is the water consumption of the plant, is difficult. Therefore, the purpose of this master thesis is to establish a model where the district heating net?s leakages but also the water consumption of the plant can be followed daily. The project is performed at Vattenfall´s district heating power plant in Uppsala. Information is gathered through discussions, drawings of the plant and guided tours of the plant.

Utveckling av en ny tillverkningslina

This report contains results of our study at CTC in Ljungby. CTC produces heating products such as boilers, heat pumps and additional products to their heating systems.The purpose of the report is to make a proposal how CTC will supply their new production line for heat pumps with materials. The proposal includes a production layout and a scheme for how to place the material in the production storage.The new production line will produce two different products and both of them have several variants. The line will also have a mixed flow, so the products can be produced in a random order. These conditions demand that the production line has great flexibility and that the material to all the variants can be stored in the production storage.With these conditions as input we made a layout proposal to the company.

Low Temperature Waste Heat Solutions : with proposals for energy technological actions based on Scania?s building 64

The report comprises two separate parts:part 1:  Temperature needs for district heating in the paint shop for axles in building 210part 2:  Energy and low temperature waste heat solutions in heating and cooling systems for   building 64 with surroundingsThe paint shop for axles in part 1 has air quality requirements in places for coating of axles. Toachieve desired air properties there are different process ventilation systems, which consist ofventilation coils for heating and cooling, plus air humidifier. The ventilations coils for heating usedistrict heating. Today the ventilation coils use water of 100°C to achieve necessary air demands inthe coating boxes. This part of the report investigates whether the existing system would achievethe air requirements with a water temperature of 75°C instead of 100°C in the ventilation coilsduring the coldest parts of the year.

Produktutveckling av mobil förstahjälpenstation

This thesis is about a part of the marquetrytechnique, scorching. Scorching is made by heating up something, put a veneer into the heated substance and make a controlled burning. This technique is old but still used today and have according to me great potential for development. In my work I wanted to give the scorching greater room then I earlier have seen. I wanted the scorching to be the dominant ingredient for a decorative element in a piece of furniture or an interior.

Hydraulisk och termisk grundvattenmodellering av ett geoenergilager i Stockholmsåsen

Geothermal energy can be extracted from an aquifer, where the groundwater is used as heatexchange medium while heat and cold are stored in the surrounding material in the aquiferand to some extent in the groundwater. Application of aquifer storage for the use ofgeothermal energy is mainly used in large scale facilities and is limited to sites with suitableaquifers in the form of ridges, sandstone and limestone aquifers.Löwenströmska hospital in the municipality of Upplands Väsby, north of Stockholm, islocated nearby the northern part of the Stockholm esker. This means that it can be profitableand environmentally beneficial for the hospital to examine the possibilities of aquifer storagein the esker material next to its property.The purpose of this master thesis has been to investigate if geothermal energy storage with aseasonal storage of heat and cold can be applied within Löwenströmska hospital?s propertyarea using groundwater modeling. A hydraulic groundwater model was constructed inMODFLOW based on a simplified conceptual model of the groundwater system.

Konstruktion av värmespridare med grafit för flygelektronik

This master thesis was carried out for Saab Avitronics, a business unit of Saab ABactive in electronic systems for military aircrafts. Reliability and weight are of crucialimportance in this environment. To improve reliability and lower the weight graphitemay be used for electronics cooling. Graphite is an anisotropic material and hasthereof high thermal conductivity in two directions (in-plane) and a relatively lowconductivity in the third direction (through thickness).The purpose of this thesis was to investigate if graphite is an adequate thermalconductor to use in PCB carriers. The carriers support and cool the PCB by divertingthe heat dissipation from the PCB components to the edge.

Tylö: Sauna Lighting

Tylö AB is the leading manufactor of sauna cabins in Europe, but there is a lack of a sauna lightning produced by Tylö. The project of developing a new sauna lightning series was assigned two students at the developmentengineering program at Halmstad University. The main problem with lightning in the sauna is the heat and security aspect. The selection fell on LED technology as the lightning source, thanks to its small measures and low heat emission. The work of constructing of a lightning armature which the capability of cooling down the LED lightning was carried out during autumn ?06 and spring ?07.

Tylö : Sauna Lighting

Tylö AB is the leading manufactor of sauna cabins in Europe, but there is a lackof a sauna lightning produced by Tylö. The project of developing a new saunalightning series was assigned two students at the developmentengineeringprogram at Halmstad University. The main problem with lightning in the saunais the heat and security aspect. The selection fell on LED technology as thelightning source, thanks to its small measures and low heat emission.The work of constructing of a lightning armature which the capability of coolingdown the LED lightning was carried out during autumn ?06 and spring ?07.

Energiberäkningar för passivhus

AbstractClimate and environmental issues are of paramount importance. Researchers agreethat we must all contribute to a reduction of gases that contribute to climatechange. Energy consumption must decrease within all sectors and the promotionof renewable sources of energy must be introduced.Each sector should aspire to decrease its energy consumption. Energyconsumption is strongly linked to waste gases that contribute to climate change.Passive houses are a part of the construction industry's methods to attain energyconservation.Passive houses are derived from low energy houses and super insulated houses. Apassive house is intended to obtain heat from the inhabitants and through theiractivities.

Energibesparing genom styrning av kontorsbelysning

Den här rapporten redogör för det arbete som, i samarbete med Sapa Industriservice AB, gjorts för att modernisera belysningsinstallationen i en specifik kontorsbyggnad på Sapas industriområde i Finspång, kallad Byggnad 80. Syftet med arbetet var att minska belysningens energianvändning. Precis som i många andra äldre fastigheter har inte några åtgärder genomförts för att undvika onödig elförbrukning och med dagens stigande energipriser samt skärpta miljökrav ställs det allt större krav på energianvändningen.Rapporten inleds med en kort teoridel för att klargöra vilka metoder som finns för att styra belysning. Därefter redogörs för hur den befintliga installationen ser ut, hur kravspecifikationen för belysningsstyrningen togs fram och hur en provinstallation genomfördes. Rapporten avslutas med resultatet från provinstallationen samt förslag på hur arbetet kan vidareutvecklas.Arbetet har dels visat att det finns stora vinster att göra om det redan vid planeringen av en nyinstallation tas hänsyn till hur elförbrukningen kan minimeras, dels att det inte är lika lätt att nå bra resultat om hänsyn ska tas till den befintliga installationen vid en ombyggnation..

Identifikation av produktionsstörningar och obalanser vid tillverkning av golvskenor

Our report procedure identification of instability and disturbance in an automatic manufacturing line of processing and assembling of chair sliding rails at Sapas manufacturing department in Vetlanda.To obtain a stabile ground we have mapped the material flow to receive a comprehensive view and to visualise connections.We have examined cycle times at different stations in purpose to identificate bottlenecks. The result of our examination showed that the bottleneck of the line was the brush station. This leads to that the expected bottlenecks identificated by Sapa gets a delay time and by that a longer cycle time.Interruptions has a clear negative influence at the line performance so we have also assemble data through the operators report list and compiled these in order to find out the interruptions effect on the line. The outcome during our assembled period was that the reported interruptions corresponded about 30 percent of the total available production time. This has a clear negative effect on the line productivity and efficiency as we have calculated in order to get the present status..

Fra?n passivhus till NNE-hus : va?gen till ha?llbar utveckling

sustainable development by reducing the energy use by EU:s directive of energy efficiency and the UN Convention. The second purpose is to present the technical solutions regarding ventilation and heating system that is being used in passive houses. This was done using 8 passive houses, 4 germany and 4 swedish passive houses. Even the international and Swedish system requirements for passive houses have been addressed in this project. The goal was also to explain how and why the mechanical system in passive houses has developed to the technology used today.

<- Föregående sida 12 Nästa sida ->