Sökresultat:
273 Uppsatser om Retained voltage - Sida 5 av 19
Utvärdering av Raman- och IR-spektroskopi, differentiell svepkalorimetri och dielektrisk spektroskopi för materialstudier på choklad
On a request from the water sewage plant Gryaab in Gothenburg a power quality survey wasperformed. The voltages and currents have continuously been sampled in the incoming 10 kVsubstation HSP01 from April-August 2008. Power quality measurements were also performedin Gryaabs other 10 kV substation HSP04 fed from HSP01 and at the terminals of theinduction motor IN_PU4040 of 1.3 MW which controls one of the four large inflow pumps tothe plant. The reason for the latter measurement was due to registered negative transients eachtime the motor was connected to the grid. The cause of the transients could be explained by thecoupling in the substation, the ageing of the motor which could result in damage of thebearings or resonance in the motor circuit which amplifies high frequency harmonics.
Ny princip för spänningsreglering i Fortum Distributions mellanspänningsnät i Stockholm.
The voltage regulation in Fortum Distributions medium voltage network in Stockholm does not work satisfactory. This results in too high distribution voltages with many customer complaints as a consequence. The reason is the model responsible for compensating for voltage drops in the distribution network. Despite several adjustments Fortum has not been able to find the source of the high voltages and has therefore appointed an investigation in the form of a thesis work.The aim of this investigation is to locate the error and to produce a proposal regarding the solution of this error using the existing system, common industrial knowledge, state of the art research and the option to use voltage readings from the different substations.The conclusion of this master thesis is that the largest contribution to the high voltage levels is made by the large compensation for distribution loses. Furthermore an additional error in the model has been found.
Värmning av avloppsvatten med spillvärme för att förbättra kvävereningen -Temperaturens inverkan på kvävereningen
The goal for this master thesis project has been to investigate the power quality in adistribution grid, which has a high fraction of dispersed power production due towindmills. The study has been done on a grid in Laholm South of Halmstad, whereapproximately 45 windmills are connected to the distribution grid owned by SHKEnergi. The investigation has been focused on to two radialy fed 20 kV lines, wheretwelve windmills are connected.Voltage variations have been studied by creating a model of the grid in the simulationprogram SIMPOW. The largest deviation that has been found in any point of the gridis ±1.9 % of the nominal voltage. This deviation is a result of varying powergeneration from the windmills and the voltage regulation at the connection point ofthe line.
Evighetsträd
FSC (Forest Stewardship Council) is the major form of certification system in Swedish forestry today and its more than 11 million hectares are covering almost half of the total productive forest area in the country. Its regulations prescribe that at least 10 wind firm trees should be left behind after every clear cutting operation.
This study have taken place on 30 recently clearcut objects in Bergslagen, Sweden, were an inventory of the standing stock have been made. The research shows that, with 90 % security, the retained trees together contain 9-13 m3sk per hectare. Pine is the dominant tree and it covers more than half the numbers of retained trees and its volume cover 65 % of the retained trees total volume. Spruce is on second place with 30 % of the retained trees, but only 21 % of the standing stock.
Vakuumbrytare i småskaliga vattenkraftstationer
This master thesis has been performed at Vattenfall Power Consultant in Gothenburg and Trollhättan for Vattenfall Vattenkraft. In this report vacuum circuit breaker in small-scale hydropower stations with the rated power 4 MVA and below has been studied. Models of the stations are modeled and analyzed in PSCAD/EMTDC to study the high voltage transients that are created after current chopping with vacuum circuit breaker. Vacuum circuit breaker may chop the current before it reaches zero value, which means that high voltage transients can be created. The equipment of the stations can be destroyed by high voltage transients.The purpose of this thesis is to examine the use of vacuum circuit breaker in small-scale hydropower stations and the risk for high voltage transients from current chopping.According to the results there is a risk of high voltage transients after current chopping with small synchronous generators in stations with the operating voltages 0.4 kV and 3.6 kV.
Konstruktion av förstärkare och insamplingssteg till en PSAADC i 0.25 um CMOS
The aim and goal of this work has been to design and implement a voltage reference network for a 12-bit PSAADC, Parallell Successive Analog to Digital Converter. A chip containing the design has been sent away for fabrication. Because of the long processing time, no measurement data are presented. The main specifications for the voltage reference generator is to generate stable reference voltages with low noise and a good PSRR. Efforts has also been made to minimize the power consumption..
Acceptansgränsen för solceller i lågspänningsnät : Kan den ökas?
Microproduction, also called distributed generation, is something that has become more and more popular in the electric grid. Microproduction can however lead to unacceptable performance if several units are installed in the same low voltage network. It is therefore good to know a limit where the performance of the low voltage network becomes unacceptable based on given parameters. This limit is usually called hosting capacity.In this report the hosting capacity with respect to voltage and current have been studied in three low voltage networks which are located in Falu Elnäts concession area. This has been done by simulations in a GIS-program where critical times of the grid have been simulated.
Frekvens och spanningsskalning i en inbyggd mikroprocessor; for att mojliggora implementationen av schemalaggning med stod for dynamisk frekvens- och spanningsreglering for energihantering.
Minimizing power consumption is a critical part of many embedded design projects. Thechallenge is to limit the power consumption of the system and at the same time providesatisfactory service to the user. With regards to microprocessors, the main way of limiting powerconsumption during program execution is to adjust the frequency and the voltage at which theprocessor operates.To enable the implementation of real-time scheduling with support for dynamic voltage andfrequency scaling, an exhaustive study of the Freescale i.MX31 embedded microprocessor isperformed. Specifically, the power consumption relationship to all relevant frequency andvoltage settings is investigated. In addition, to enable frequency and voltage scaling in a real-timeenvironment, a complete timing analysis of proposed voltage and frequency scaling methods isperformed and their suitability for use in real-time systems is evaluated.To integrate voltage and frequency scaling capability into OSE RTOS, a software module hasbeen developed for this operating system.
Beredning av lokalnät i landsbygd
In this thesis a rural network in Norrbotten, Sweden, has been to designed and planned with the purpose of improving distribution reliability by exchanging existing overhead lines with underground cables. General network design considerations are discussed as well as the ones for the specific low voltage grid. During the design phase the maximum power of domestic consumers has been estimated using Velander?s method. Currents, voltage drop and impedance of the network have been calculated and fuse operation and selectivity has been considered.
EMC problematik och el-kvalitet i elkraftnät
The dissertation deals with an account of actual problem, which can arise within EMC and power quality. The cause of power interruption and what can be done to minimise the power interruption is discussed. It also includes a definition of planning levels and which factors one needs to have control over to carry out a possible planning strategy and how the local distributions net could be more secure. The electrical net could be secure but no system can be free from interruption.The dissertation examines two distribution transformers: GLA40T1 (Glansås) and T399 in Tranås Energy which don?t have regulators.
Inställning av automatikermed spänningsreglerande verkani det sydsvenska 400-130 kV nätet
The voltage level in the power grid varies due to variations in load and production. Normally these variations are manageable, but they may be excessively large during a disturbance. If the voltage is too high it may damage the equipment in the grid and too low voltages may cause problems like voltage instability. The magnitude of the voltage variation depends on the short circuit power capacity of the point of interest.This problem may become lore prominent due to automatic voltage regulation that acts on shunt reactors and shunt capacitors. When the shunt reactor is connected or disconnected to the grid it may cause such large changes in the voltage that the shunt reactor starts hunting.
Spänningsstyrd underfrekvenslastfrånkoppling i elektriska kraftsystem
This report is a Master?s Thesis performed by Andreas Adolfsson and David Jacobsson atChalmers University of Technology. The purpose of this master?s thesis is to evaluate anew method for load-shedding, the voltage controlled underfrequency load-sheddingdeveloped by ABB. This report presents a comparison between conventionalunderfrequency load-shedding and this new method for load-shedding.
Framtidens elbilar utmanar nutidens elnät : Påverkan av ett ökat antal elbilar på ett halländskt elnät
The challenges facing low voltage grids are rising as an increasing number of domestic houses transition from fossil fueled heating to electricity based heating. Several environmental goals and visions have the same transition from fossil based power to electricity based power in mind for the transportation sector. One of the most important tools for this transformation is widely regarded to be the electric vehicle. With the demands of the electric vehicle pressuring the power grid, several questions arise regarding the growth of the electric vehicle market and what repercussions it may have on the grid. This paper focuses on a typical low voltage grid in southern Sweden and what effects a growing electric vehicle market may have on it. Through computer-assisted simulations based on several future scenarios regarding the EV market, this paper finds that few modifications and reinforcements are needed on this particular grid within the next 10 to 15 years.
Utveckling av högspänningskontakt
This report describes the development of a high-voltage connector at the request of Scandinova Systems AB in Uppsala. The development process is described from the making of a customer demand specification, to the making of drawings for the manufacturing of prototypes. Scandinova develops high-voltage modulators, hence the need for connectors that can handle very large power pulses. Their current connector has several weaknesses that may cause the connector to melt or catch fire. The development began with a number of studies that included the modulator structure and the current connector structure and functions.
Konstruktion av UPS-modul
This master thesis describes the development of an UPS module. UPS is an acronym for Uninterruptable Power Supply. The UPS module has been developed at the company AerotechTelub AB. The UPS module delivers the necessary voltage and current in case of a power interrupt. If a power interrupt occur, the computer system has one to three minutes available to store data and shut down correctly.