Sök:

Sökresultat:

529 Uppsatser om Rectal temperature - Sida 3 av 36

Betydelsen av kolkälla och mikrobiell fysiologisk status för temperaturresponsen (Q10) vid nedbrytning av organiskt material :

The increasing threat of climate change has led to a increased need for models to predict future climat. In these models the changes in the soil carbon pools due to changes in microbiel degradation of the organic matter can lead to both positive and negative feedback-effects. There is however a lack of consensues on the temperature respons on degradation soil organic matter. This paper aim to give a better understanding on the factors controlling the temperature respons. The factors studied were the carbon substrate qualitity and the physiological status of the microorganisms.

Studie av Karlskogas fjärrvärmenät för att sänka returtemperaturen

A district heating plant has the advantage that it can take advantage of the waste heat from industries and use of cheap fuels to produce heat. But for the long term is competitive requires that energy is also saved in district heating plants. One way to save energy in a district heating system is to increasing cooling to the return temperature. This leads to less power needed to drive the distribution pumps,  and that more energy could be extracted from the same amount of fuel by an improved flue gas condensation.In Karlskoga the return temperature into the district heating plant is high. They would therefore reduce the return temperature in order to extract more energy from the flue gases.

Adaptiv temperaturreglering av bostadshus

The control of indoor temperature must be able to handle large time constants and both measureable disturbances like outdoor temperature, and non-measurable disturbances, like waste heat from appliances. Due to cheaper microcontrollers (small computers with designated tasks) with better performance, more advanced and computation-demanding methods for control can be used.In this thesis, Generalized Predictive Control (GPC) has been implemented and tested on a theoretically derived model of a house. GPC states that a model of the system is estimated in every sample, and the control is carried out simultaneously, based on predictions of the model. Disturbances like solar radiation can be estimated and used in the control as well. The control signals are determined by quadratic programming, which makes it possible to consider conditions, for example limitations on the control signals.GPC requires a number of parameters to be defined, like model order and control signal penalty, but is relatively robust for variations in them.

Dendroklimatologisk analys av lokalklimat vid Grövelsjön i Dalafjällen

Climate on earth is getting warmer, which effects earth?s energy balance and so forth the ocean and atmospheric circulation.  In many sub-polar regions on the northern hemisphere changes due to warming of the climate can be observed. Some examples that already have been observed are shifts in tree line, towards higher altitudes and latitudes, increased ablation of Swedish glaciers and melting of the permafrost on the Siberian tundra. In Sweden climate change scenarios tell us that it will become warmer and that a higher amount of precipitation in form of rain will be an effect from this. To study climate changes in Sweden, transition zones are useful in order to observe changes in distribution of species and animal populations.

En studie av Uppsala stads värmeö

The urban heat island is an area restricted to a city center where the temperatureis higher than its surrounding environment. The greatest temperature difference isfound at night when the weather is calm and the sky is clear of clouds. There are twomajor causes behind this phenomena and the first one is the use of energy forheating of houses. The heat leaks through the walls of the buildings and warms upthe surrounding mass of air. The second one is the use of building material whichstore the suns radiation on daytime and releases the heat during night.

Fysikalisk modellering av klimat i entreprenadmaskin

This masters thesis concerns a modeling project performed at Volvo Technology in Gothenburg, Sweden. The main purpose of the project has been to develop a physical model of the climate in construction vehicles that later on can be used in the development of an electronic climate controller. The focus of the work has been on one type of wheel loader and one type of excavator. The temperature inside the compartment has been set equal to the notion climate. With physical theories about air flow and heat transfer in respect, relations between the components in the climate unit and the compartment has been calculated.

Termisk analys av kompakta jordvärmesystem - Sensitivitetsanalys och korrektions faktorer baserat på fältmätningar i referensanläggningar i Östergötland

Chapter 1 defines the aim of the project and gives a general orientation about ground heat extractors. In chapter 2 physical processes that could be expected to be involved in the heat transport around a ground heat exchanger are discussed. It is shown from a literature study what amount of moisture transport due to thermal gradients there could be expected in a ground heat exchanger. The conclusion is drawn that the moisture gradient (Sr) is of same magnitude as the driving temperature gradient (°C). At the expected amount of increased moisture around the pipes the moisture transport could be considered to have a little effect on the brine temperature.

Hygienisering av torkat bioavfall

The main project Dry preservation of food waste from households includes a new technique concerning drying and storage of dried biowaste as well as a study of the sorting of household waste and further usage of the dried biowaste. A question asked in the project is, can the dried biowaste be used as a soil amendment? If organic waste is used as a soil amendment, precaution concerning hygienic safety risks has to be accounted for. The objective of this M. Sc.

Kylkedjan för snittblommor - en kartläggning av distributionen

Title:Chillchain for cut flowers ? how the distribution works.Author:Anna-Maja Svarén, student at Lund Institute of Technology, mechanical engineering.Supervisors:Annika Olsson, Department of Design Sciences.Bengt Sahlberg, Bioett AB.Problem:How does the distribution of cut flower works regarding temperature, losses, responsibility, complaints, packaging and weak points?Purpose:The purpose is to map the distribution of cut flowers, with focus on losses in the temperature, from farm to store. The goal is to identify weak points in the chillchain and to se how wrong temperatures affect the flowers. The results can be a help to secure the chillchain.Method:The work started with a problem; map the distribution of cut flowers with focus on temperature losses. Data was collected on the basis of this problem, then analysed, and finally conclusions were drawn.Conclusions:The affect handling and distribution has on a cut flower is very complex.

TILLFÄLLIGA EFFEKTTOPPAR I FJÄRRVÄRMEN : Kan man med hjälp av lagrad värme undvika att de uppstår i betonghus?

Climate and environmental issues is now high on the agenda. We live in a generation that must try to solve some major environmental problems. Buildings and habitations account for approximately 40 % of Sweden's total energy today. To reduce this figure, as needed, more research in the field of energy efficiency is required.This thesis concerns the heating of buildings. The load on district heating is heavy during certain times of the day.

MOLNU : Att utveckla ett gemensamt gränssnitt

Climate and environmental issues is now high on the agenda. We live in a generation that must try to solve some major environmental problems. Buildings and habitations account for approximately 40 % of Sweden's total energy today. To reduce this figure, as needed, more research in the field of energy efficiency is required.This thesis concerns the heating of buildings. The load on district heating is heavy during certain times of the day.

Utvärdering av laddningskoncept för lastbilsbatterier

When drivers overnight in the truck lots of electric energy is consumed by heaters, fans, lights and other extra equipment. If the engine is not running, this energy is taken from the lead/acid batteries of the truck which then needs to be recharged during operating hours. The fact that the charge acceptance of the lead/acid batteries is dependent on the temperature makes it hard to fully recharge the batteries at lower temperatures. A negative charge balance can lead to starting problems within a few days use in cold climate.In this thesis work, the effects of different battery charging concept are evaluated on the most common Scania battery (175Ah). A battery model is implemented in Matlab and some simulations of charging are made.

CFD simulering av kallras : Undersökning av temperatur- och luftbeteende intill höga glasfasader och i vistelsezon med golvvärme som en värmekälla

Glass has sophisticated front properties and are used as facades in high buildings. During cold periods, these glass facades could cause thermal discomfort, due to cold downdraught. Cold downdraught can be countered by placing heaters under glass surfaces. Nowadays technology offers highly insulating windows, which is why there is an interest to investigate the indoor climate with only underfloor heating. The research in this area is limited, and few empirical methods are available.

Utveckling av en ytmonterad fördelningsmätare som underlag för individuell debitering av vattenförbrukning i fastigheter

The master thesis, conducted at Metrima AB, concerns the development of a non-intrusivedistribution meter as a basis for individual tap water billing in apartments.The project is conducted in response to the market interest in individual tap water billing inapartments as an answer to environmental concerns regarding water consumption. Due to thehigh installation cost of traditional water meters, a new method of determining waterconsumption, without having to cut water pipes, is proposed.The proposed method distributes the total water consumption for an apartment complex toindividual apartments according to distribution meters, measuring water run-time, in eachapartment. The water run-time is estimated by measuring the water pipe?s outward vibrationsand temperature changes.A test environment was established and a prototype built, using a tilt- and vibration sensor forvibration sensing and a precision temperature sensor to measure temperature changes. As bothsensors work well in the test environment, further testing was done in 3 apartments for aduration of 5 days.

Sekundärnät för lågtempererad fjärrvärme

Lower energy use in buildings is a result of increasingly stringent energy requirements across Europe. When conventional district heating technology is used in areas with low energy consumption heatlosses do not fall even though the amount of energy delivered is reduced. This reduces income for thedistrict heating company. To maintain their economic viability the district heating companies? majorchallenge is to implement new solutions that minimize heat loss.

<- Föregående sida 3 Nästa sida ->