Förskolor med passivhusteknik : En utredning av passiva förskolor
As a result of directives from EU, with the ambition to reach environmetal goals, The German organisation Passivhaus Institut has defined a passive house. A passive house is a building that is very energy efficient and makes a small impact on the environment. The energy from the inhabitants as well as the appliances & fixtures in the building should equal the energy that is required to heat the building. A Swedish version of the passive house definition has been defined, taking into account the climate conditions and the difference in building regulations.This thesis is a request from Skanska on how it can improve and develop an ongoing passive house project, involving an infant school. The intention of this thesis is to identify difficulties & display potential development areas for infant schools.The method of research conducted is as follows: interviews of clients, ventilation consultant, consultant for heating system and an energy calculation consultant, an inspection of the infant shcool in process, investigation of completed infant schools and a study of relevant literature.From this research it was found that it is difficult for infant schools to pass the criteria for passive houses. The conclusion of this thesis provide several guidelines on how to improve the outcome of existing projects & the steps needed to be taken for future development in this area..
Jämförelse av stenull- och polyuretanisolering : Brand- och fuktegenskaper i passivhuskonstruktion
This report compares two different types of insulation with regards to fire and moisture. The materials were tested for the company Fiskarhedenvillan AB, for a wall and a roof construction that the company currently uses in the establishment of Sweden's first certified passive house for international standards.Their current material, Rockwool, is compared to a relatively new material on the Swedish market called SEALECTION Agribalance sold by the company ISO Green AB. The material is a type of polyurethane insulation. This insulation material would result in a more efficient execution of the construction as it provides waterproofing and is applied more easily than Rockwool. From a fire standpoint, literature studies and discussions with fire experts led to results.
Plusenergi och dess installationer : Kvarter Trettondagen
The latest thing in the area of environmental building today is energy-plus-house. The idea behind the energy-plus-house is to create a house that produces more energy than it consumes. To accomplish this, the house uses renewable energy, in this particular case solar energy. With the help from a proper construction and thoughtfully projected installations you can achieve a surplus of energy. The surplus energy can then be sold to the surrounding buildings and thereby conduce to a financial profit for the household.
Erfarenheter från flerbostadshus som passivhus : En handflata och sex värmeljus
All new households were to be constructed with "near zero energy house standards" (NZE-house) by the year of 2020. The ambition to construct energy-efficient buildings had to increase rapidly in the spring of 2013.The purpose of this report was to increase the interest for building contractors to construct apartment buildings with passive house standards. By locating and evaluating experiences from an existing passive house a case study including interviews, field visits and document analysis was made. Research of literature regarding other passive houses in Sweden also helped to answer the following questions:- What positive and negative experiences have the study of the passive house meant to the involved stakeholders and residents?- What improvements can be made based on identified experiences?- How can an apartment building be designed as a passive house based on possible improvements?By collecting good and bad experiences, as well as improvements and potential design proposals, a diagram was created designed as a tool for developers when constructing apartment buildings with passive house standards.
Lufttäta byggnader
The viscosity of air buildings is a hot topic within the construction performers, which the industry feel they have too little knowledge about. This study is mainly aimed against air density in apartment buildings and airflow measurement. The study consists of a theoretical reference, educational visit, interviews and a survey conducted among construction workers at Magistratshagen in Linkoping.Earlier requirement in terms of air leakage through the climate screen was removed and today there are only energy requirement for a dwelling in Boverkets Building Regulations. The difference between a passive and a typical air tight construction is that the passive house have a maximum requirement of 0.3 l /s m2 of air leakage through the building climate screen. The requirement imposed on passive houses is to minimize the supply of power and energy for heating the building.Air tight constructions have heavy demands on the performance and accuracy of everyone involved with the project. The client must specify their requirements and also be prepared to pay for any additional costs. The architect and building planners have to design the building with regard to air tightness. Finally, the construction workers are required to do a careful work in order to get all the connections in the building air tight.The study suggests that an air tight building is a closed system where no forced ventilation exists. There are no reasons not to build too tight as long as there is a functioning ventilation. In this study the authors ask themselves how an air tight building changes over time. No theoretical information has been found on these changes, but the respondents assume that air density decreases with time. The deterioration is mainly assumed to be caused by construction materials changes over time. The study shows that construction workers knowledge of air tight construction is mixed, which they themselves admit in the survey..
Det självförsörjande passivhuset
The housing sector uses 40 % of the energy in Sweden and half of the electricity usage. Theuse of energy is the main reason to the increasing rate of carbon dioxide in the atmosphere.This is the main motive but also a wish of higher safety, that is a higher rate of selfsufficientenergy production in Sweden, we want to decrease the need of using fossil fuel. Now whenthe energy price rise, the interest in energy issues increase and more people discuss thepossibility of reducing the usage of fossil fuel. A change to renewable energy such as sun,wind and water is the only solution where we can get a sustainable development.One way to contribute to a better use of energy is to build in the principle of passive house.The house is being built with a thick and tight insulation. If you use a heat-exchanger withhigh degree of efficiency and a final heating battery on the ventilation system, the heat fromlamps, devices and the ones living in the house should be enough to fulfil the criteria ofliving.
Prefabricerade passivhusväggar
Background: The most energy efficient houses today are so called passive houses. These houses achieve high energy-efficiency partly by having well insulated walls. U-value describes the amount of heat transfered through a building element, the more insulation, the smaller U-value. A typical passive house wall have a U-value of 0.10 W/m2,°C. The passive houses are primarily made as small family houses and not as a block of apartments.
Energiberäkningar för passivhus
AbstractClimate and environmental issues are of paramount importance. Researchers agreethat we must all contribute to a reduction of gases that contribute to climatechange. Energy consumption must decrease within all sectors and the promotionof renewable sources of energy must be introduced.Each sector should aspire to decrease its energy consumption. Energyconsumption is strongly linked to waste gases that contribute to climate change.Passive houses are a part of the construction industry's methods to attain energyconservation.Passive houses are derived from low energy houses and super insulated houses. Apassive house is intended to obtain heat from the inhabitants and through theiractivities.
Investeringsbeslut för energieffektivisering i monarken
The purpose of this essay is to describe how Boverkets Byggregler has affected the cost ofnewly built houses from 2003 to 2012, to Boverkets Vision 2025. The purpose is also to findagent-principal relations in the construction sector.When investing in an energy efficient house the operating costs are reduced compared to aconventional house. But due to the lower operating costs, the investment cost rises. In thisstudy, we find out if it is economically viable to invest in an energy efficient house comparedto a conventional house from the customer's perspective.The study's approach has been qualitatively where we in collaboration with Derome Hus hadaccess to three conventional reference houses and a passive house and data that was necessaryto conduct viability assessments on houses. We conducted five interviews with people fromDeromekoncernen and Varbergs kommun.The calculation methods we have used in this study are present value method, annuity methodand a sensitivity analysis.
Investeringsbedömning av energieffektiva småhus i trä
The purpose of this essay is to describe how Boverkets Byggregler has affected the cost ofnewly built houses from 2003 to 2012, to Boverkets Vision 2025. The purpose is also to findagent-principal relations in the construction sector.When investing in an energy efficient house the operating costs are reduced compared to aconventional house. But due to the lower operating costs, the investment cost rises. In thisstudy, we find out if it is economically viable to invest in an energy efficient house comparedto a conventional house from the customer's perspective.The study's approach has been qualitatively where we in collaboration with Derome Hus hadaccess to three conventional reference houses and a passive house and data that was necessaryto conduct viability assessments on houses. We conducted five interviews with people fromDeromekoncernen and Varbergs kommun.The calculation methods we have used in this study are present value method, annuity methodand a sensitivity analysis.
Primärenergianvändning av passivhus i Sverige : Med fokus på Kvarteret Trettondagen
The building sector accounted for around a fourth of the total energy usage in Sweden in year 2010 (Energimyndigheten, 2012). Therefore it has become very interesting to achieve a lower energy usage in residential buildings. One way to achieve that is to build so called passive houses. By being very well insulated and have low leakage through the walls, they can reduce the energy usage for heating with a substantial amount. The first passive house was built during the 90?s in Germany; and in Sweden the first passive house was built in Gothenburg 2001.
Engergieffektivt Bostadsområde : Förstudie Till Aktivhusområde i Halmstad
In the thesis we have shown that it is possible with current technology, to buildneighborhoods that are largely self-sufficient. We have obtained some information aboutongoing work in the field of energy efficient buildings and active house which we have usedto develop a model. The feasibility study for Ranagård we have e.g been forced tofollow laws on groundwater covered, resulting in the construction of basements for singlefamilyhome is not possible. The model that we have built up overtime has been the central part of the work. The model illustrates very well what an activehouse neighborhood means and potential of such an area.
Simulering av energieffektiviserande åtgärder för små- och flerbostadshus : Möjligheter för JM:s hustyper att uppnå passivhuskonceptet vid nybyggnation
The purpose of this project was to evaluate how energy efficiently some of JM?s residential buildings can become in standard production. What kind of measures are needed to achieve the level of energy demand that is included in BBR12 (Boverkets Byggregler)? What measures are needed for achieving a lower demand so that the buildings could be classified as passive houses? The investigation has included a single family house and two different types of apartment blocks.The simulation programs Enorm and VIP+ have been used to calculate the energy demand of the buildings. The results from the programs have been compared with the measured energy demand for the three buildings.
Radon i betongkonstruktioner : - Kan det undvikas?
The following article consists of two parts; one part is about house construction and the other is a specialization about radon. The house construction part describes how to project a house from start. It contains the conformation of the house, the installations needed, calculations considering the strength of the construction, energy calculation and what materials were chosen. Calculations considering the costs of building and operate the house has been carried out. The result showed that the house would cost approximately two million Swedish kroner to build and thirteen thousand kronor a year to operate.
Studium av stomsystem och övrigt klimatskal m.a.p. produktion och långsiktig förvaltning av passivhus
The passive house concept has been known for many years, but it is not yet verywell known in Sweden. The increased energy requirements places greaterdemands on our buildings and to meet these requirements, passive houses is agood option.Svenska Bostäder have built passive houses with good results and intend tocontinue design some of their new buildings as passive houses. This study ismeant to support Svenska Bostäder in their planning of new buildings byanalyze and compare the different frameworks and building shells of passivehouses.In the first chapters (1,2 and 3) we presents the conditions for passive housesand the differing objects we have examined more generally for the reader tobecome familiar with the concept and the objects.The subsequent chapter presents an analysis of each object partial based on thespecifications from FEBY and finally, in Chapter 5, you will find a table ofvalues where the objects are put into relation to each other and valued there by,together with a brief explanation for the table.This chapter also contains texts on the environment, design and futuredevelopment which all includes our own thoughts and reflections.Finally, the gist of the whole work and our conclusion is presented anddiscussed.On the whole, the work has been very enlightening for us and we hope that theconcept of passive houses have a wider impact in the future..