Sök:

Sökresultat:

5469 Uppsatser om On-site wastewater treatment systems - Sida 2 av 365

Jämförelse mellan våtkompostering och andra VA-system i omvandlingsområden : en fallstudie i Norrtälje kommun.

Eutrophication of the Baltic Sea and Swedish lakes remains a major problem despite many years of effort to reduce the emissions of nutrients. One major source is waste water systems, especially private sewage systems. These sewages accounts for a very large share of nutrients per capita in comparison with citizens connected to larger sewage treatment plants. Norrtälje community has the greatest number of private sewage systems in Sweden. Discharges of nutrients, especially phosphorus, to the Baltic Sea from these sewage systems are significant.

Biologiska behandlingsmetoder för rening av rejektvatten från biogasproduktion

In this literature review the characteristics of two free-floating macrophytes, water hyacinth   (Eichhornia crassipes) and duckweed (Lemna sp.), and two microalgae, Chlorella and Scenedesmus, have been examined regarding their suitability as efficient nutrient removers in the treatment of wastewater with high levels of nutrients and suspended solids from a biogas plant in Loudden. The needs required for the plants to be able to grow in wastewater and the amounts of biomass they can produce have also been studied. The results show that Chlorella is capable of a very high uptake of nutrients in photobioreactors with high nutrient loadings. With an ammonia uptake maximum value at 10900mg/m2/d Chlorella outshines the other organisms in this study. The test organism that performed the closest to Chlorella in terms of nitrogen uptake was water hyacinth with an uptake about 1602mg/m2/d.

Älgarås avloppsreningsverk- studie och metodisk felsökning av en biobädds BOD-rening

Wastewater contains biodegradable materials, which are often measured as BOD7.Trickling filters are sometimes used as a purification step for BOD-reduction. Atrickling filter is a tower, which is filled with a carrier material. Microorganisms growon the carrier material in the form of a biofilm. This biofilm consists mostly of bacteriathat purify water from BOD.In Älgarås? wastewater treatment plant the water is purified by a trickling filter.However the treatment plant has difficulties reaching the emission requirements forBOD.

Bedömningsgrunder och reningskrav för avloppsreningsverk, 25-2000 pe, i Laholms kommun

The aim of this project was to look into ten small sewer systems in the municipality of Laholm, in Sweden, in order to work out common assessment grounds for them. The sizes of the systems for purification of wastewater were within the range of 25 to 2000 population equivalents. Our method was to study literature, the laws and regulations applicable and the files at the municipality. The conclusion is that every sewer system is different and every situation is unique. We concluded that based on laws and assessment grounds sewer systems equal in size and pollution load ought to have similar demands attached to them.

Beräkningsmodell för massbalanser för Slottshagens reningsverk

In the next few years the pollutants loading at the Slottshagen wastewater treatment plant in Norrköping is going to increase due to the reason that one of the waste water treatment plant in the district will be shut down.A survey of how these different pollutants are divided in the treatment process is therefore necessary for mapping out both the loading and treatment efficiency.This can be achieved by studying mass balances.Mass balances were carried out for the water treatment process for the mechanical/chemical,biological and the chemical stage.The mass balance studies show that the treatment efficiency was very good. However in order for the mass balances to be quite consistent and to ensure complete coverage of results and conclusions i.e. more reliable results, sludge samples should be collected and taken at different times per day and the influent rate should be investigated.In this work mass balance has been set up in order to illustrate and identify the factors that should be considered and taken care of for further estimation using mass balances in the future. Furthermore this survey results in a calculating model for the mass balances at thisplant.This calculating model is used as a tool to facilitate future calculations for mass balances for the water treatment process at Slottshagens wastewater treatment plant.Moreover it provides a basis for carrying out further estimation of the treatment process in the near future.In this project the importance of some operating parameters was also taken in consideration.This calculating model can be modified so that calculations of such operating parameters i.e. sludge loading and sludge age can be easily performed.Such information can be used further to evaluate different operation alternative in order to ensure an optimal use of the treatment process with in the plant..

Bättre enskilda avlopp i Sigtuna kommun : möjligheter för bebyggelse i Odensala socken

There are around 855 000 on-site sewage systems in Sweden and some 1 800 of these are located in the municipality of Sigtuna. The Sigtuna local authority has set the goal that all sewage systems with insufficient function should be improved before the end of year 2010. A malfunctioning on-site sewage system may cause three main problems: spreading of diseases, discharge of eutrophicating compounds and wastage of resources. The municipality strives to reduce these problems already at the stage of granting permits for installation of on site sanitation systems. The municipality has recently adopted new guidelines, which demands certain minimum reductions for different compounds. The guidelines also state that it is preferred that neighboring house-owners cooperate in jointly built and operated sewage systems and that the system should be able to recycle plant nutrients.

Total organic carbon (TOC) and chemical oxygen demand (COD) - Monitoring of organic pollutants in wastewater

Total organic carbon (TOC) and chemical oxygen demand (COD) are two methods used for measuring organic pollutants in wastewater. Both methods are widely used but the COD method results in production of hazardous wastes, including mercury.The purpose of this study was to validate the method TOC that will replace COD and find a factor to convert TOC to COD. In this study 26 samples were analyzed from four sewage treatment plant in the municipality of Enköping.The results show that the COD method could be replaced by the TOC method.The factor for COD/TOC was between 3.1 - 3.3. Both methods will be used in parallel until 2013 when it will be forbidden to use the COD analysis..

Industriella avloppsvatten i Chile : Identifiering av problem samt förslag på åtgärder

Chile and Santiago are struggling with heavy environmental problems as a consequence of urbanisation and industrialisation. In the Santiago region the air is seriously contaminated and most of the rivers are classified as heavily polluted.The aim of this thesis is to survey the industrial fluid waste situation in the Santiago region and to make suggestions on technological improvements or process changes. The purpose is also to study five different enterprises more closely and to give more detailed suggestions for improvement. Another purpose is to summarize relevant Chilean legislation.Information, provided by the supervisory authority, about the release of industrial wastewater to rivers has been analysed. Deep interviews have been made with authorities and consultants.

Kungsängsverket : ett reningsverk omvandlas till park

Today, there are few industries left in our cities. Industrial areas thatare located in urban settings close to water or city centers are oftenreplaced by housing. In my thesis I want to explore how such industrialsite located in an urban setting can be transformed into anindustrial park where the industrial structures are saved. By approachingthis type of environment in a positive manner, I wish tohighlight the potential aesthetic and functional value in the existingindustrial structure. Through the transformation and design of anexisting industrial site I will convey the previous use and history ofthe place.The wastewater treatment plant, Kungsängsverket, is located in thedistrict of Kungsängen in the southern part of Uppsala.

Cleaning process of abattoir wastewater with focus on bacterial pathogens

This study was conducted at the City Abattoir in Kampala, Uganda to evaluate the cleaning process, with focus on bacterial pathogens, in a pilot scale integrated bioprocess. This consisted of four steps: anaerobic sequencing batch reactors; aerobic/anoxic sequencing batch reactors; a high performance temperature controlled methanogenesis digester and a constructed wetland. The objective was to determine if this type of cleaning process could be used to clean wastewater from abattoirs in a satisfactory way. The indicator organisms for faecal contamination, Escherichia coli and Enterococcus spp. were used to investigate in what numbers bacteria could be found in the untreated wastewater and how much that was reduced in the different steps of the cleaning process. The water was analysed for Salmonella to see if human pathogens could be found and could survive the different steps of the treatment process.

Textilindustrins avloppsvatten och avloppsslam ur ett miljöperspektiv : Underlag för internationella riktlinjer inom projektet Sweden Textile Water Initiative

The aim of my thesis is to obtain knowledge of textile wastewater and textile sludge from an environmental perspective, which can be used as a basis for the  ?Sweden Textile Water Initiative? guidelines for a sustainable sludge management. In my study I have mainly focused on textile dyes, salts and metals and their routes during wastewater treatment.This paper is partly a literature review, which I began by identifying the pollutants discharged from each textile process. Then I studied wastewater and sludge quality, environmental aspects, possible treatment and recycling methods. I have also tried to find existing type of guidelines in order to make comparisons.

Kemisk karaktärisering samt nedbrytning av process- och avloppsvatten vid SCA Ortvikens pappersbruk

During pulp and papermaking process a huge amount of water is used. The wastewater contains a large amount of pollutants and has to be treated before it reaches the recipient. In March 2004 a new bleaching plant was started up at SCA Graphic Sundsvall AB, Ortviken?s paper mill using peroxide. The production of bleached thermo mechanical pulp and thus the load to the wastewater plant increased.

Närsaltsdosering till luftad damm : en åtgärd för ökad TOC-reduktion hos Skoghalls Bruk luftade damm

In the process of making carton boards into Skoghall Mill, are great quantities of water being contaminated. This water has to be treated before it is possible to release into the recipient, Kattfjorden. One of the contaminations that is important to extract from the wastewater, is organic carbon (measured as TOC-total organic carbon) because microbiological breakdown can lead to the bottom becomig free of oxygen.The wastewater treatment at Skoghall Mill is done through an external wastewater treatment that is located at the factory. The biological treatment (aerated lagoon) is a 140 000 m3 water pool with surface aerator, which is give oxygen to the water. In the lagoon live microorganisms who performs the biggest part of the TOC-reduction.One problem with the lagoon is that the treatment of TOC is considerably worse during wintertime than during summertime.

Uthållig sanitet : en förstudie i staden Picota, Peru

The access to good sanitary facilities is an important factor that elevates the experienced living standard as it improves hygiene and reduces the transmission of deseases. The ratification of the millennium goals by 189 countries demonstrates that this is an important international issue. Together the countries have taken upon themselves that the proportion of the population that lacked access to sustainable safe drinking water and sanitary facilities in the year 2000 will have been reduced by half by the year 2015. In Peru, the construction of sewage pipe networks to transport the sewage out of the direct human environment is progressing. The safety and sustainability of these systems can be questioned, since in Peru the sewage seldom receive any treatment before being emitted to a recipient. This is taking place in Picota and sorrunding villages as well. In the last 25 years several systems implementing small-scale onsite treatment have been introduced throughout Latin America in an attempt to give more people access to sustainable and safe sanitary facilities, reducing water consumption and taking advantage of the agricultural values of the sewage fractions while protecting the environment from its negative impact. In this study three different sanitary systems and the effects of different population growths were compared.

Hydrauliken i Ångersjöns fosforfällor : bestämning av flödesvägar och åtgärdsförslag för optimal fosforbindning vid avloppsrening med reaktiva filter

Discharge of untreated wastewater leads to unnaturally high levels of nitrogen and phosphorus in rivers, lakes and the sea, which results in unbalanced ecosystems with eutrophication and lack of oxygen. Part of the phosphorus in surface waters is coming from on-site wastewater treatment from scattered households with unsatisfactory purification. Blast furnace slag is a by-product from iron production, and has in laboratory trials showed good phosphorus binding capacity. To test blast furnace slag as a reactive filter media for phosphorus separation in a full scale experiment, a wastewater treatment plant has been built behind the picnic area at Ångersjön alongside the road E4 in central-eastern Sweden. The plant contains two parallel lines, one with blast furnaces slag and the other with Filtralite-P as phosphorus sorbent. Both filters have showed decreasing phosphorus purification effect with time in spite of a low wastewater load.

<- Föregående sida 2 Nästa sida ->