Sök:

Sökresultat:

245 Uppsatser om Mineral wool insulation - Sida 3 av 17

Alternativa byggsystem för att minska transmissionsförlusterna på miljonprogrammets byggnader

The purpose with this project is to explore and verify three renovating systems for Miljonprogrammet (common expression forbuildings constructed during the years 1965-1975 when over a million houses where built in Sweden) to take measure to thelargely transmission losses of these buildings. Many of the buildings from this period have similar constructions and thereforethe same techniques can be used to renovate several of them. This project only considers the climate scale, although thereare many more factors to concern for to efficient the buildings of Miljonprogrammet.This thesis presents examples of renovations carried out using two of the three renovation systems.The essay presents a reference house of choice on which we apply the three systems and calculate the new U-values,consumption of energy and the investment costs. The new U-values the building is given is matched to the values ofrecommendation for passive houses. Our reference house is a two story apartment building, located in the village ofLammhult, with brick facades at the ends and plaster at the long sides.

Flexibel isolering av fönster för att minska energiförluster

The first part of this essay is about a single-family house that we have planned and projected. Thesecond part is a deeper study in ways to further insulate windows when they are not in use.In the first part the building?s design and its most important construction elements are described.The planning of all major installations (heating, domestic water, ventilation, sanitation, electricity)are reported so that one can in principle start construction of the house. In addition there arecalculations done on the building?s energy management.The result is a two stored house angled toward the south.

Isolerande balkonginfästningar : Thermally-insulated balconies

In this work a study has been performed to show the different kinds of insulated balcony connections exists on the market. In the work there is also a short description of thermal bridges concerning balconies. A description of older solutions for balcony connections is given as well as a calculation of the difference in energy costs for a insulated balcony connection compared to the standard connection. The work includes a short description of the different products. After that there is a short information about their insulation properties, durability, acoustic performance, assembly, computer programme and a short analyses for each product..

Jämförelsestudie av tilläggsisolering

Rapporten behandlar och utvärderar tre olika isolermaterial, Polyisocyanurat (PIR), grafitcellplast och mineralull, vid tilläggsisolering av miljonprogrammets byggnationer.  Stora delar av miljonprogrammet är nu i behov av upprustning. Samhällets skärpta krav gällande energiförbrukning gör att nya rationella metoder och material krävs för att tillgodose ställda krav. Att tilläggsisolera är en del i denna upprustning, och eftersom valet av isolermaterial ofta faller på gamla beprövade metoder och materialval, såsom mineralull, syftar denna rapport till att öka kunskapen om alternativa, mer högpresterande isolermaterial.Isolermaterialens egenskaper tas först upp och behandlas i en generell jämförelse där ekonomiska och tekniska aspekter beaktas.För att konkretisera och påvisa utfallet i ett specifikt fall genomförs en studie för ett referensprojekt, kvarteret Hundlokan, som ägs och förvaltas av Fastighets AB Förvaltaren. I studien undersöks tre olika alternativ för vart och ett av materialen vid tilläggsisolering utvändigt av Hundlokans fasader. Samtliga alternativ ställs sedan mot varandra och utvärderas med hjälp av: fukt-, U-värdes-, energi-, kostnads- och LCC-beräkningar (livscykelkostnad).Enklare fuktberäkningar som påvisar relativ fuktighet (RF), ånghalt och temperatur i väggens olika skikt genomförs.

Mineralämnen i fullfoder : studier på 20 mjölkkogårdar i Halland

In 2003 the recommended phosphorus allowance for dairy cows in Sweden was lowered approximately 10 %. For a cow at a production level of 35 kg ECM it decreased from 0,40 to 0,36 % of dry matter. To investigate if the decrease has been implemented at farm level, analysis of following minerals; P, Ca, Mg, K, Na, S, Se, Cu, Mn and Zn was performed on the TMR at 20 farms in Sweden in the summer of 2004. The purpose was to describe the actual allowance of different minerals as compared to the new recommendations. One hypothesis was that the decrease in recommended allowance of phosphorus would lead to the need of new mineral feeds on the market.

Energianvändning för markkonstruktioner förlagda med ytvärme : En teknisk och ekonomisk utredning av fördelarna med att isolera under värmerören

The need for snow-free surfaces at squares, bus stops, platforms, car parks and sports facilities increases and at the same time energy price rise and the environment is becoming a hotter issue. The construction of the ground heating systems often lack thermal insulation under the heating pipes, which means that the heat from the pipes not only warm up the soil surface but also heats the surrounding soil. The insulation also has more features, by insulating the risk of frost damage is minimized. The goal of this report is to demonstrate the large heat loss and energy costs in the absence of insulation under the heating system.The report begins with a scientific way to study and treating the soil heating system uses, and the theory involved. Furthermore it also deals with different routing principles of heat pipes depending on the facility.All calculations are made with so called finite element method (FEM), in COMSOL Multiphysics 3,5a, where models are created with different conditions.

Tilla?ggsisolering och fuktproblem i grundkonstruktionen platta pa? mark : En fallstudie i flerbostadshus inom stadsdelen Sa?tra i Ga?vle

Between 1965 and 1974, the Swedish Parliament decided to build one million dwellings, called Million Program. The million program buildings were erected with new, untried design solutions, in a short range of time, and at low cost. The residential buildings from that time are now greatly in need of renovation. The municipal housing company, Gavlega?rdarna, renovates and improves the energy efficiency at some of it?s apartment buildings in the district Sa?tra, Ga?vle.

Elektrisk skorstenständare

Between 1965 and 1974, the Swedish Parliament decided to build one million dwellings, called Million Program. The million program buildings were erected with new, untried design solutions, in a short range of time, and at low cost. The residential buildings from that time are now greatly in need of renovation. The municipal housing company, Gavlega?rdarna, renovates and improves the energy efficiency at some of it?s apartment buildings in the district Sa?tra, Ga?vle.

Fuktomlagringar i välisolerade ytterväggar : En undersökning för att fastställa en rimlig inbyggnadsfuktkvoti träreglar med fuktsimuleringsprogrammet Wufi 2D

To save energy it?s popular to build houses with low energy loss. In these houses the walls are keeping a lower temperature in the external side which leads to a higher relative humidity. In addition more material, such as wood studs, are used which means that there is more moisture to dry. More moisture in combination with higher relative humidity may pose a higher risk of microbial growth.

Mikroskopering av opaka faser - en studie från Skyttgruvan, Falun.

In nature there are about 4,500 minerals identified. These can roughly be divided into two groups, opaque phases and non-opaque phases, with the exception that some opaque phases also may act as a non-opaque phase in different circumstances. The division is made on the basis of the optical properties. Opaque phases are nontransparent, which means that a different type of microscope must be used. A conventional microscope uses transmitted light while the microscope for opaque phases or the ore microscope uses reflected light.

Energihushållning och varsamhet för äldre byggnader : Chefsbostaden i Strömsholm, ett timmerhus från 1900-talets början

This report is the result of a degree project in building engineering, at an advanced level. The project evaluated a building from a technical and historical point of view, and focused on its energy consumption, particularly the energy used for heating. The building in question was a small apartment building in Strömsholm, Sweden. It was made in 1902, from vertical logs, a not so common form of the traditional log house. The goal of the project was to evaluate if the energy consumption could be reduced in accordance with building preservation regulations, that is without damaging any of the building?s cultural or historical values.The building was surveyed with the help of archive and literature studies, interviews and inspections.

Slam ? en outnyttjad resurs i skogsbruket

Every year about 210 000 tones dry weight of sewage sludge is produced in Sweden. Most of the sludge is applied to agricultural land, plantsoil and landfill cover. Sewage sludge contains essential nutrients such as nitrogen and phosphorus. Nitrogen is limiting growth on solid ground in Sweden and can therefore be used as fertilizer to increase productivity. In order that the sludge can be spread to forest land it requires first a conversion of sludge to pellets, to make it more manageable.

Kvarnkretssimulering för test av styrsystem

This thesis has been carried out in autumn 2009 at Uppsala University for Boliden Mineral AB. Physical modelling has been used to model a comminution circuit. The model has then been linked to a PLC.When a concentrator is about to become operational Boliden Mineral AB have been looking for a way to test the PLC. The purpose of this report has therefore been to develop models for the subprocess in a concentrator and link these models to the PLC. The subprocess was a comminution circuit in Aitik36.

Analys av fuktomlagring i välisolerad parallelltak : Analys med simuleringsprogrammet Wufi 2D

Idag ökar man isoleringen alltmer i takkonstruktion för att spara energi. Ökad mängd isolering minskar temperaturen över takets yttre delar och höjer den relativa fuktigheten där.  Dessutom finns risk att fuktigt material byggs in mellan alltmer täta skikt vilket leder till att det tar längre tid för byggfukten att torka. Detta resulterar i en ogynnsam fuktfördelning med höga relativa fuktigheter över konstruktionen där risken för mikrobiell påväxt ökar. Syftet med denna studie är att utreda hur fuktomlagring sker baserad på inbyggnadsfuktkvoten i välisolerade parallelltak.

Tillämpning av högpresterande isolering : PIR-isolering - ett effektivt isoleringsmaterial

Högpresterande isolering är en typ av material som finns tillgängligt men inte används på den svenska marknaden i den utsträckning som de bör göra. I denna rapport kommer det högpresterande isoleringsmaterialet PIR att ligga i fokus och det jämförs främst med det traditionella isoleringsmaterialet cellplast men paralleller dras även till mineralullen.PIR- isoleringen har 40 % bättre värmekonduktivitet än cellplasten och detta innebär att materialet har bättre isoleringsförmåga som bidrar till tunnare konstruktioner. Isoleringen är därför idealiskt att använda för passiv-, lågenergi och nollenergihus. En annan egenskap som utmärker PIR- isoleringen är dess brandegenskaper som uppfyller en högre brandklass än cellplasten, trots att det är ett plastmaterial.PIR- isoleringen är ett dyrare material, dock sparas pengar in redan vid produktion då fukt- och vindskydd kan uteslutas i en konstruktion. Om högre energikrav ska uppfyllas kan pengar även sparas in på sikt genom lägre energikostnader..

<- Föregående sida 3 Nästa sida ->