Sök:

Sökresultat:

564 Uppsatser om Mekanisk ventilation - Sida 2 av 38

Energi- och miljöanalys av processavdelning.

Arbetet går ut på att genomföra en miljö- och energianalys av två pressgrupper i processhallen. Detta innebär att dagens process skall analyseras för att se om man genom olika system kan göra arbetsklimatet bättre för operatörerna samtidigt som en besparing av energi möjliggörs..

Värmeförluster vid utvändigt placerade ventilationssystem

To be able to handle tomorrows need for limited energy consumption we need to reduce our use of energy. The building sector stands for around 40 % of all energy consumption in the society. The government has put up a goal to reduce the energy consumption in our buildings with 20 % by year 2020 and 50 % by year 2050 compared with year 1995. To be able to do reach that goal we need a more energy efficient building stock.The main part of the energy used in our buildings is used for space heating. By installing ventilation systems with heat recovery on the exhaust air it is possible to use the heat-energy in the exhaust air to warm up the incoming air.

Sjuksköterskors kommunikation med patienter som vårdas i respirator : Nurses? communication with patients during mechanical ventilation

Aim: The aim of this study was to describe intensive care nurses? experiences communicating with patients during mechanical ventilation.Methods/design: A qualitative interview study. Interviews where analyzed using descriptive content analysisSetting: Nine intensive care nurses from two different intensive care units were interviewed using a semi structured interview guide.Background: Past research has shown that patients during mechanical ventilation in the intensive care unit, feel very vulnerable and the helplessness of being unable to speak. These patients feels that they are completely dependent on the nurses and their competence. It has been shown to be very important that the patient feels included, acknowledged and respected.Results: The analyzed data resulted in a theme; through communication strive to preserve patients´ dignity and three main categories; create relationship to the patient, minimize patients´ vulnerability and don´t give up.

Energianalys av luftbehandling

Elanvändningen till ventilation har ökat med 40 % sedan 1990 i Sverige. Ventilationen är en miljöbov enligt undersökningar som visar att elanvändningen till ventilationssystemens fläktar kan reduceras. Minskning av elförbrukningen kan t.ex. uppnås genom utbyte av fläktmotor till en EC-motor eller till en fläkt med bakåtböjda skovlar och direktdrift. Effektivieringsåtgärder kan ge en lägre elförbrukning på upptill 50 % i vissa applikationer.Ventilationsfläktarna i Sverige förbrukar 12,3 TWh per år.

Aktiv bullerdämpning i ventilationssystem

Active headsets have been on the market for years and now it is time for something else to enter the stage. The technology of active noise reduction can for exmple also be used in ventilation systems for reducing ventilation noise. An active control system principally consists of four important components, namely the downstream error microphone, the upstream detection or reference microphone, the digital signal processor (DSP) and a loudspeaker. The upstream reference microphone listen to the primary ventilation noise and sends it to the DSP which makes a phase shift to the signal and sends it to the loudspeaker. The loudspeaker sends out the opposite waveform of the incoming one and reduce the primary ventilation noise.

Inhysningsrelaterade faktorer som påverkar förekomsten av luftvägsinfektioner hos kalvar

Luftvägssjukdomar är ett av de vanligaste hälsoproblemen hos kalvar och utgör en betydande kostnad för branschen. Luftvägssjukdomar är komplexa till sin natur och uppkommer endast då en kombination av faktorer som inkluderar djuret, miljön och infektiösa agens förekom-mer. Ofta är den primära patogenen ett virus och den påföljande lunginflammationen orsakas av bakterier. Ett bidragande virus, BVDV, har genom ett frivilligt kontrollprogram utrotats i Norden och det finns potential att utrota även BRSV. Genom en ökad förståelse för biosäker-het och hur ventilation av mikromiljöer, gruppstorlek och ålderssammansättning påverkar smittrycket och luftvägshälsan hos kalvar kan byggnader och management-rutiner som mini-merar risken för respiratoriska sjukdomar utformas..

Kommunikation hos respiratorvårdade patienter : Upplevelser hos patient och vårdpersonal samt analys av samtal med och utan röstgenerator

?Studies have shown that patients receiving mechanical ventilation in an intensive care unit (ICU), who are entirely dependent on the nursing staff, often experience frustration due to a temporary loss of the voice source. Limited communication is an important factor contributing to patient discomfort. Nursing staff also report communication as frustrating and difficult.The aim of the present study is to introduce a neck-type electrolarynx as a communication aid in an ICU, to study the nursing staff experiences of communication with tracheotomized patients receiving mechanical ventilation, and to examine the patient´s experiences regarding communicative abilities. Communication between a ventilator treated, tracheotomized patient and members of the nursing staff was recorded and analyzed according to principles of Conversation Analysis (CA).The results show that several members of the nursing staff experience difficulties communicating with tracheotomized patients receiving mechanical ventilation.

Aktiv bullerdämpning i ventilationssystem

Active headsets have been on the market for years and now it is time for something else to enter the stage. The technology of active noise reduction can for exmple also be used in ventilation systems for reducing ventilation noise. An active control system principally consists of four important components, namely the downstream error microphone, the upstream detection or reference microphone, the digital signal processor (DSP) and a loudspeaker. The upstream reference microphone listen to the primary ventilation noise and sends it to the DSP which makes a phase shift to the signal and sends it to the loudspeaker. The loudspeaker sends out the opposite waveform of the incoming one and reduce the primary ventilation noise.

Effektiv lagerstyrning genom tillförlitlig prognostisering : Effective inventory control through reliable forecasting

This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.

Tätning eller ventilering mot fukt på kalla vindsutrymmen

This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.

Energieffektivisering i flerbostadshus : Undersökning av lönsamheten med energieffektivare ventilation

This thesis is based on a case study for the real estate manager Mimer in Västerås. Mimer provides a great deal of this city?s rental apartments. Many of their buildings have ventilation systems with a type of heat-recovery called ?heatpipe?.

Luftfuktighetens påverkan på konstruktion och klimat i en berghangar

Aeroseum is an aviation museum located in an old military underground hangar. The ventilation system in the hangar is designed for the military purpose of the hangar. This design includes a solution with air flowing through the space between the construction of the hangar and the rock surface. The solution is intended to avoid a buildup of inflammable gases. This design leads too high humidity levels in the hangar.

Energikartläggning av förskolan Smultronstället

Detta är ett examenarbete på grundnivå, 15 högskolepoäng. Examensarbetet är en energikartläggning med rekommenderade energieffektiviseringsåtgärder. Energikartläggningen är baserad på ett verkligt objekt vilket är en förskola i norra Gävle. Denna skola förvaltas av Gavlefastigheter.I Sverige går cirka 40 % av energianvändningen till bostäder och service. Därför finns det stora mängder energi att spara inom denna sektor.

Mekanisk slamavvattning : vid Sibbhults avloppsreningsverk

Detta examensarbete behandlar slamhanteringen på Sibbhults avloppsreningsverk (Sarv).I denna rapport tas det upp hur avvattningen och förtjockningen av slammet går till i dagsläget och vilka förändringar som kan göras för att förbättra dessa processer.Här visas även vilka eventuella vinster som kan fås med förändringar och eventuella investeringar i en avvattningsapplikation. Redan med små medel kan förtjockningen av slammet förändras, även om det inte införskaffas en mekanisk avvattnare, som t ex med inblandning av polymerer i avloppsvattnet.För att finna olika fungerande alternativ har information insamlats från flera företag som tillhandahåller applikationer för slamavvattnare. Information har även införskaffats genom egen erfarenhet under min verksamhetsförlagda utbildnings (VFU) period på SArv, och vid diskussion med personal som arbetar vid vatten- och avloppsreningsverken i Östra Göinge kommun..

Utvärdering och åtgärdsförslag av energianvändning i kontorsbyggnad

AbstractEmbla 5 is an office building which has done a large improvement. The clients of this building has made an order of WSP and the student Anders Kempe to calculate the use of energy for the building, and after that result proposing further measures which can decrease the energy use of Embla 5.The ground for this report is when calculation of the present energy use of the building is stated. To make that information of a number of parameters such as envelope, the heating system and ventilation has been located and set in to the simulation program IDA ICE which calculate the energy use.To improve the energy use further this project has been concentrated to change the system of ventilation. Today the ventilation system is of the kind CAV (constant air volume) and the air flow is dimensioned for after recommendations from BBR and Arbetsmiljöverket in the office spaces. Consider that Embla 5  is an office building where the people only staying for 8-10 hours/day so was the ide to see how much energy saving if the air flow is reduced the time people not being in the building.

<- Föregående sida 2 Nästa sida ->