Sök:

Sökresultat:

112 Uppsatser om Insulation - Sida 2 av 8

Isolerande balkonginfästningar : Thermally-insulated balconies

In this work a study has been performed to show the different kinds of insulated balcony connections exists on the market. In the work there is also a short description of thermal bridges concerning balconies. A description of older solutions for balcony connections is given as well as a calculation of the difference in energy costs for a insulated balcony connection compared to the standard connection. The work includes a short description of the different products. After that there is a short information about their Insulation properties, durability, acoustic performance, assembly, computer programme and a short analyses for each product..

Energianvändning för markkonstruktioner förlagda med ytvärme : En teknisk och ekonomisk utredning av fördelarna med att isolera under värmerören

The need for snow-free surfaces at squares, bus stops, platforms, car parks and sports facilities increases and at the same time energy price rise and the environment is becoming a hotter issue. The construction of the ground heating systems often lack thermal Insulation under the heating pipes, which means that the heat from the pipes not only warm up the soil surface but also heats the surrounding soil. The Insulation also has more features, by insulating the risk of frost damage is minimized. The goal of this report is to demonstrate the large heat loss and energy costs in the absence of Insulation under the heating system.The report begins with a scientific way to study and treating the soil heating system uses, and the theory involved. Furthermore it also deals with different routing principles of heat pipes depending on the facility.All calculations are made with so called finite element method (FEM), in COMSOL Multiphysics 3,5a, where models are created with different conditions.

Tilla?ggsisolering och fuktproblem i grundkonstruktionen platta pa? mark : En fallstudie i flerbostadshus inom stadsdelen Sa?tra i Ga?vle

Between 1965 and 1974, the Swedish Parliament decided to build one million dwellings, called Million Program. The million program buildings were erected with new, untried design solutions, in a short range of time, and at low cost. The residential buildings from that time are now greatly in need of renovation. The municipal housing company, Gavlega?rdarna, renovates and improves the energy efficiency at some of it?s apartment buildings in the district Sa?tra, Ga?vle.

Elektrisk skorstenständare

Between 1965 and 1974, the Swedish Parliament decided to build one million dwellings, called Million Program. The million program buildings were erected with new, untried design solutions, in a short range of time, and at low cost. The residential buildings from that time are now greatly in need of renovation. The municipal housing company, Gavlega?rdarna, renovates and improves the energy efficiency at some of it?s apartment buildings in the district Sa?tra, Ga?vle.

Energihushållning och varsamhet för äldre byggnader : Chefsbostaden i Strömsholm, ett timmerhus från 1900-talets början

This report is the result of a degree project in building engineering, at an advanced level. The project evaluated a building from a technical and historical point of view, and focused on its energy consumption, particularly the energy used for heating. The building in question was a small apartment building in Strömsholm, Sweden. It was made in 1902, from vertical logs, a not so common form of the traditional log house. The goal of the project was to evaluate if the energy consumption could be reduced in accordance with building preservation regulations, that is without damaging any of the building?s cultural or historical values.The building was surveyed with the help of archive and literature studies, interviews and inspections.

Tillämpning av högpresterande isolering : PIR-isolering - ett effektivt isoleringsmaterial

Högpresterande isolering är en typ av material som finns tillgängligt men inte används på den svenska marknaden i den utsträckning som de bör göra. I denna rapport kommer det högpresterande isoleringsmaterialet PIR att ligga i fokus och det jämförs främst med det traditionella isoleringsmaterialet cellplast men paralleller dras även till mineralullen.PIR- isoleringen har 40 % bättre värmekonduktivitet än cellplasten och detta innebär att materialet har bättre isoleringsförmåga som bidrar till tunnare konstruktioner. Isoleringen är därför idealiskt att använda för passiv-, lågenergi och nollenergihus. En annan egenskap som utmärker PIR- isoleringen är dess brandegenskaper som uppfyller en högre brandklass än cellplasten, trots att det är ett plastmaterial.PIR- isoleringen är ett dyrare material, dock sparas pengar in redan vid produktion då fukt- och vindskydd kan uteslutas i en konstruktion. Om högre energikrav ska uppfyllas kan pengar även sparas in på sikt genom lägre energikostnader..

Koppartvål Möjligheterna att isolera mässing från läder och därigenom förhindra att tvål uppstår

Uppsats för avläggande av filosofie kandidatexamen iKulturvård, Konservatorprogrammet15 hpInstitutionen för kulturvårdGöteborgs universitet2012:22.

Konflikten mellan bevarandekrav och tilläggsisolering : The conflict between conservation requirements and additional insulation

Sweden has formulated ambitious energy goals which signify that by year 2050 the energy usage should be halved. One of the objectives is the reduction of energy usage by 20% by year 2020 and that it should be compared to the usage of energy from 1995. In parallel with increased energy requirements for buildings the demand on housing conservation, by highlighting also buildings from the last 50 years as part of the building heritage, continues to enhance, which in theory means that there is a conflict between these.The law will never be able to point out unique buildings and PBL (planning and building act) is not especially concrete. The National Housing Board has tried to make this more concrete by the new BBR regulations though there are still an enormous variety of interpretations.This report deals with the conflict between conservation requirements and additional Insulation of the building envelope and is limited to multi-residential buildings built between the years 1945 and 1975. It is the stock with the greatest energy consumption and that is where the big challenge lies.

Potentialen av värmebesparing i ett avlopps luftningsledning

This thesis aims at determining the heat losses in a property vent stack and its roof valve. Upon request of a company, the vent stack is analysed for possible heat recovering solutions to be implemented, while relining of the drain system is executed and with a suitable payback time for the economic investments. The heat loss calculations are based on data for properties that are located in the Stockholm region, but also easy to change depending on the situation. The calculations are done on pipes made out of cast iron, which still is the most common type of drain pipe in Sweden, and these are the pipes that relining is usually made on. The calculations that needed to take several variables into account have been done in MatlabR2014a and the thermos dynamical properties that were used in those calculations have been extracted from EES.Three different types of heat losses in the vent stack have been taken into consideration in this thesis.

Energiförbättrande åtgärder på befintliga flerbostadshus : -En lönsamhetsanalys

The EU Council adopted in 2007, environmental and energy goals with the aim of them must be met by 2050. This, in combination with those of the Swedish government 15 enacted environmental goals is supposed to lead the way for the Swedish environmental work.This report has examined measures in properties in the Swedish Cooperative Housing Society (SKB) stocks.The report discusses a range of measures that might be appropriate to apply on the properties to make them more energy efficient.One of the measures discussed, the vent whose primary purpose is to create a good indoor environment for the residents but is also where the most energy is lost.Another measure discussed is Insulation of the building envelope on the estate to make it more energy efficient. To put extra Insulation on the building envelope is important because of the large amount of energy that is lost through the walls, ceilings and floors.Future actions that may be implemented is individual billing of heating and hot water. This system has been used in European countries since the 70's and today the EU wants to increase the own individuals control over their electricity costs. This has led to a discussion whether to implement the system in Sweden or not.However, there are a number of equitable measures to be sorted out before the system can be used in any great scale.Finally, it is important to remember that environmental measures should be the primary and the pursuit of cost reductions the secondary otherwise you risk the environmental work to be counterproductive..

Preparering av kabelände inför statorlindning

At Uppsala university scientists have during the last years developed and built wave energy converters. This project is called "Lysekilsprojektet". The development has come so far that they are currently investigating how to gain profit in a mass production. For that reason they want to automate as many steps in the production as possible.The winding of the stator is one part that is being automated using industry robots. The stator is cable wound unlike many other generators.

Energieffektivisering av befintliga sjukhusbyggnader - Analys med avseende på kostnad och energibesparing

The climate changes that are occuring in the world have resulted in that the EU callingfor a 20 % reduction in energy consumption to the year 2020, to reach that goal theEU want the public sector to go forth as a good example. Västfastigheter owns andmanage the hospital buildings in the Västra Götaland region. To be able to reducetheir energy usage Västfastigheter has hired several consulting firms to chart out theenergy consumption on each hospital building. The biggest energy savings potentialhave been calculated and what the cost will be to perform each action. The energyaudit have been completed and stand as the decision basis for Västfastigheter?s choiceon which action packages that should be implemented.

Studie av värmeflöden i befintligt bostadsbestånd : Utvärdering av energieffektiva besparingsåtgärder

The purpose of this master thesis is to investigate different types of measures for making buildings more energy efficient and to estimate their profitability. The calculations were performed with the building simulation program VIP+ and the evaluation of the profitability with the life cycle cost method. Furthermore, it was examined how losses in the distribution of secondary systems of district heating can be avoided. Options to replace district heating with a local district heating system based on bio-energy have been investigated. The possibilities of achieving more efficient thermal energy consumption and production for the chosen estate were also examined.The object of the study has been a residential estate with 133 detached houses in Uppsala, built in 1974.

Laborationsmätning av vindtäthetens betydelse för en väggs U-värde

To fulfill the climate target that EU and the Swedish government have decided to apply, it becomes increasingly important that the energy efficiency of existing buildings and making new buildings energy efficient as possible. Of Sweden?s total energy consumption in 2011 was 40% used by residential and service. Of the 40% of the energy consumption was 60% used for heating and domestic hot water. A report from year 2012 shows that one reason why the heating volume is so great could be due to underestimating on the energy consumption for the heating in the planning of the building.

Utfackningsvägg av lättbetongblock i passivhus

AbstractThis report intends through a case study to investigate if lightweight concrete isappropriate as main material in the outer wall of a seven storey residential building.A technical design is carried out in accordance with the definitions and requirementsfor passive houses, given by FEBY?s1 ?Demand specification for passive houses?.A literature review is also carried out for a comparison between regular bolt wall andlight weight concrete wall, with a focus on the safety of moisture.The lightweight concrete block used in the report is as a celblock produced by thecompany H+H Sweden AB.The methods used have resulted in compliance with requirements andrecommendations from authorities. Calculations of energy, noise and moisture riskassessment has been carried out.The work has resulted in the conclusion that the lightweight concrete itself is notable to isolate in the extent necessary to obtain chosen U-value of 0,1 W/m2 ° C,without getting to thick. Therefore additional Insulation is needed. There are fewrelevant reference objects built with only light weight concrete.

<- Föregående sida 2 Nästa sida ->