Sökresultat:
199 Uppsatser om Insulation thickness - Sida 4 av 14
Strömningen i och över en skog : utvärdering av en 'mixing-layer' hypotes
A new theory for predicting the windprofile over a canopy has been evaluated. The theory was first presented by Harman and Finnigan (2007). The theory relies on the forming of a mixing-layer above the canopy, due to different mean wind in and above the canopy. Characteristics from both mixing-layer and Monin Obukhov similarity theory have been used to develop the governingequations that give the wind profile. The theory has been used to calculate wind profiles for sixdifferent atmospheric stabilities.
CFD-simulering av kallras från fönster : Konvektorers och nischdjupets inverkan på lufthastigheter i rummet
During cold winter days it is likely that people in buildings with older windows or high glass facades experience thermal discomfort due to cold air down draughts. Earlier work has been aimed at finding analytical methods to predict the speed of the airflow in a room and in practice heating appliances are often placed beneath the windows to reduce the draught along the floor. In a study from 2012 Mohammad Parchami developed a method for estimating the required heating power to counteract the downdraught with such heating appliances. In this study, Computational Fluid Dynamics (CFD) was used to evaluate the usefulness of Parchami?s method and also to examine the potential of adapting the depth of the inward window sill as a means of decreasing the down draught.
Utfackningsvägg av lättbetongblock i passivhus
AbstractThis report intends through a case study to investigate if lightweight concrete isappropriate as main material in the outer wall of a seven storey residential building.A technical design is carried out in accordance with the definitions and requirementsfor passive houses, given by FEBY?s1 ?Demand specification for passive houses?.A literature review is also carried out for a comparison between regular bolt wall andlight weight concrete wall, with a focus on the safety of moisture.The lightweight concrete block used in the report is as a celblock produced by thecompany H+H Sweden AB.The methods used have resulted in compliance with requirements andrecommendations from authorities. Calculations of energy, noise and moisture riskassessment has been carried out.The work has resulted in the conclusion that the lightweight concrete itself is notable to isolate in the extent necessary to obtain chosen U-value of 0,1 W/m2 ° C,without getting to thick. Therefore additional insulation is needed. There are fewrelevant reference objects built with only light weight concrete.
Upplevd trafiksäkerhet med mittbarriär
AbstractThis report intends through a case study to investigate if lightweight concrete isappropriate as main material in the outer wall of a seven storey residential building.A technical design is carried out in accordance with the definitions and requirementsfor passive houses, given by FEBY?s1 ?Demand specification for passive houses?.A literature review is also carried out for a comparison between regular bolt wall andlight weight concrete wall, with a focus on the safety of moisture.The lightweight concrete block used in the report is as a celblock produced by thecompany H+H Sweden AB.The methods used have resulted in compliance with requirements andrecommendations from authorities. Calculations of energy, noise and moisture riskassessment has been carried out.The work has resulted in the conclusion that the lightweight concrete itself is notable to isolate in the extent necessary to obtain chosen U-value of 0,1 W/m2 ° C,without getting to thick. Therefore additional insulation is needed. There are fewrelevant reference objects built with only light weight concrete.
Energieffektivisering av modern tillbyggnad till äldre skola : fallstudie från Österbyskolan i Österbybruk
The Swedish government has introduced a goal to reduce the energy intensity by 20% to the year 2020. To reach this goal actions need to be taken throughout the energy sector which includes residential and commercial buildings. This thesis considers the possibility to reduce the energy usage in a building located close to Uppsala. The analyzed building is a combined office, cafeteria and entrance and was completed about half a year before this project started. Therefore the measures presented for a more energy efficient building are presented as measures for future constructions.Simulations have been made in VIP-Energy, a dynamic energy calculation program.
Prefabricerade passivhusväggar
Background: The most energy efficient houses today are so called passive houses. These houses achieve high energy-efficiency partly by having well insulated walls. U-value describes the amount of heat transfered through a building element, the more insulation, the smaller U-value. A typical passive house wall have a U-value of 0.10 W/m2,°C. The passive houses are primarily made as small family houses and not as a block of apartments.
Specificering av produktionstransformatorer : Rekommenderade avsteg från IEC 60076 för att vid upphandling beskriva en robust enhet
As break downs of production transformers are costly and often result in long outages it is essential for reliability of operation that the transformers are manufactured to be robust. The aim of this M.Sc. thesis is to investigate if deviations should be made from the standard IEC 60076 ? Power Transformers in order to describe a robust large power transformer for procurement.The investigation has been conducted in three stages. In the first stage a definition of the term robust was developed in consultation with the client Vattenfall Vattenkraft.
Livscykelanalys av flerbostadshus ? energieffektiviseringsåtgärder för minskade koldioxidutsläpp
The importance of energy- and environmental issues has increased, and the work towards reducing carbon dioxide emissions plays a major part. The European Union has set up goals for the membership countries to work towards this to happen. The carbon dioxide emissions in Sweden have been reduced the last few years, but there is still a lot to do. About 30 per cent of Sweden?s carbon dioxide emissions generate from energy usage related to housing, this is why the housing sector is of interest to examine.
Köldbryggor och energiförluster. En studie om energiförluster genom balkonginfästningar och deras betydelse för byggnadens totala energibehov
In this report the balconies? abutments for a property in Bo01-area in Malmö has been studied. The property which is called Vitruvius contains four build-ings where two of them have corbelling balconies with intermittent abutments. With intermittent abutment means that the 50 mm thermal bridge insulation that the balconies is equipped with, is broken regularly by a 300 mm concrete heel. The reinforcement bar that holds the balcony runs through this heel.
InsuFlex : Framtagning och analys av högpresterande isoleringskoncept i sandwichelement
Rapportens huvudsyfte är att ta fram en isoleringskombination av högpresterande material, som ska bidra till ett förbättrat U-värde och reducerad väggtjocklek. Konstruktionen är baserad på en befintlig sandwichvägg från Strängbetong, där författarna ersatt den ursprungliga isoleringen med det utvecklade isolerskiktet för att slutligen studera väggarna med lika villkor. Den framtagna väggens isolerings- förmåga presenteras genom handberäkningar, där det erhålls U-värde och temperaturfördelningar mellan elementens olika skikt vid stationära förhållanden. Det har även utförts värmesimuleringar för att analysera samma fysikaliska faktorer dock baserat på 3D förhållanden.I samarbete med företag har flera högpresterande isoleringsmaterial valts ut att ingå i väggkonstruktionen. Genom fördjupade studier av materialens fysikaliska egenskaper kunde en komplett isoleringskombination utvecklas och fick namnet InsuFlex.
Luftläckage I Småhus : Hur de upptäcks och attityderna till dem
Air tightness in new buildings has been discussed for several decades. But the knowledge in the subject is low. With tougher requirements from the Swedish government about energy consumption for a new building required competences how these shall be met. It's not only the thick mess of insulation that are important, it's also the air tightness. This report is about air leakage in Swedish houses.
Uppgradering av automatisk teststation
The climate changes that are occuring in the world have resulted in that the EU callingfor a 20 % reduction in energy consumption to the year 2020, to reach that goal theEU want the public sector to go forth as a good example. Västfastigheter owns andmanage the hospital buildings in the Västra Götaland region. To be able to reducetheir energy usage Västfastigheter has hired several consulting firms to chart out theenergy consumption on each hospital building. The biggest energy savings potentialhave been calculated and what the cost will be to perform each action. The energyaudit have been completed and stand as the decision basis for Västfastigheter?s choiceon which action packages that should be implemented.
Det energisnåla isoleringsmaterialet
This bachelor essay is divided into two parts, the first being a construction of a single-familyhouse and the second an in-depth study of five different isolation materials, analysed from anenergy perspective.The first part, the construction of the single-family house, has been created from knowledgeacquired during three years of studying at KTH Royal institute of Technology in Stockholm, inthe program Architecture and the Built Environment. The constructed house is a one-floorhouse of 137m2with façade plaster, situated in Borlänge, Sweden. The house has a wooden framewhich is built on a on sight cast concrete foundation, on the ground. The house?s roof is a gableroof, which has an angle of 24 degrees.
Projekteringsförslag för JM AB av fastighet 3:2 i Bukärr, Särö
The climate changes that are occuring in the world have resulted in that the EU callingfor a 20 % reduction in energy consumption to the year 2020, to reach that goal theEU want the public sector to go forth as a good example. Västfastigheter owns andmanage the hospital buildings in the Västra Götaland region. To be able to reducetheir energy usage Västfastigheter has hired several consulting firms to chart out theenergy consumption on each hospital building. The biggest energy savings potentialhave been calculated and what the cost will be to perform each action. The energyaudit have been completed and stand as the decision basis for Västfastigheter?s choiceon which action packages that should be implemented.
Förslag till ombyggnation av klipp- och bockningsmaskin
This thesis work has been performed on request by SWT (Scandinavia WeldTech AB). SWT manufactures, develop and sell ready to assemble building systems for concrete rafter beam applications. The beams in this system consist of a u-beam that is welded to a flange. To be able to fill the beams with concrete there is holes in the beams top end. The holes are made in a ?punching machine?. These holes are cut out and the remaining steel piece is bent down in the u-beam.