Sökresultat:
666 Uppsatser om Indoor temperature - Sida 5 av 45
Köpcentrumförvaltning -Mjuka värdens påverkan på avkastningen
In this report a study is carried out with the aim to identify added values of EPC projects implemented in schools in order to increase the interest of EPC projects on the market. The report examines how the planned maintenance, supervision, maintenance and corrective maintenance is affected, how insurance premiums and terms are affected, the indoor environment and how the tasks of the operating staff is changing. A literature study of energy savings, energy use in schools, maintenance and insurance as well as how energy efficiency improvements are related to the Swedish environmental objectives has been made. Visits were carried out in Ludvika, interviews were also carried out with operation technicians and local strategists in Ludvika as well as employees of insurance companies.Schools often have neglected maintenance and problems with ventilation and indoor environment. Schools also have a large energy saving potential due to their low utilization, mainly because they are empty parts of the year.
Samband mellan en längre tillväxtsäsong och en ökad smoltstorlek i Vänerområdet
AbstractThe purpose of this study was to see if there is a connection between smolt length from Brattfors salmon cultivation and temperature. Climate changes are expected to give a higher temperature that could result in a longer growing season for the fish.Cultivated smolt is today bigger than it was before, it is also bigger than the wild salmon. The growth season of salmonids depend on the water temperature, salmonids need 6-80C to grow. Water temperature has been surveyd since the late 50´s in Brattfors. The result shows that it?s now considerable more days per year with higher temperature.
MKB för vägprojekt i Sverige: Svårigheter med att tolka och använda en MKB
In this report a study is carried out with the aim to identify added values of EPC projects implemented in schools in order to increase the interest of EPC projects on the market. The report examines how the planned maintenance, supervision, maintenance and corrective maintenance is affected, how insurance premiums and terms are affected, the indoor environment and how the tasks of the operating staff is changing. A literature study of energy savings, energy use in schools, maintenance and insurance as well as how energy efficiency improvements are related to the Swedish environmental objectives has been made. Visits were carried out in Ludvika, interviews were also carried out with operation technicians and local strategists in Ludvika as well as employees of insurance companies.Schools often have neglected maintenance and problems with ventilation and indoor environment. Schools also have a large energy saving potential due to their low utilization, mainly because they are empty parts of the year.
En flödesutjämnande driftstrategi för Uppsalas fjärrvärmesystem : En ändrad styrning av framtemperaturen
This thesis examines a possible control strategy to minimize flow fluctuations in Uppsala?s district heating system. High variations in flow rate may lead to complications caused by hydraulic constraints in the district heating system. These complications, such as inadequate pressure and temperature levels, increase the risk of heat delivery failures. It is therefore important to avoid such situations both for the producer and for the customers.Typically, the forward temperature is controlled by using a rough correlation with respect to the outdoor temperature.
Fuktproblematik i platta på mark : En analys av uppkomsten till fuktproblem
When constructing a building, a number of aspects must be harmonized in order for it to fulfill requirements ? a building must fulfill requirements such a load-bearing, conservation of energy and a good indoor environment by means of, among other things, moisture proofing .Moisture problems in buildings can affect health negatively. As we are increasingly staying in indoors, demands on a good indoor environment are higher.This work starts with examining moisture problems in slab-on-ground solutions, and then links the various scenarios to moisture problems in a concrete slab of a real building. The building with moisture problems is located in Årby by in Borlänge and moisture damage was found in the slab at an apartment adjoining wall.By reviewing literature written within the field of moisture problem, making hand calculations and modeling in the program Comsol Multiphysics, judgments are made to find explanations as to why the rise of moisture occurred in the building in Årby by.Generally, the following guidelines may be used to reduce the risk of moisture problems in slab-on-ground constructions:Drying of construction moisture before laying the floor material.Using draining layer beneath the slab, to prevent capillary suction.Using insulation under the slab, partly for comfort and to establish the temperature difference between the ground and the concrete slab.Avoid direct contact between the wood and concrete, due to degradation and fouling smells that normally occurs.If necessary, use additional vapor barrier.In addition to the above, there are various methods for moisture-proof and moisture-monitoring by design or by the method ByggaF suited for the entire construction process various events..
Effects of shade on milk production in Swedish dairy cows on pasture
Heat stress negatively influences the performance of dairy cattle such as lactation and reproduction. Heat stress can cause production losses as well as welfare problems. Years of research have shown that heat stress is a huge problem for dairy cattle in both the tropics and temperate zones but no such research have so far been done in northern European countries. It seems like shade is an important tool when improving pasture conditions and therefore
deserves more attention. The aim with this study was to investigate whether there is a need of providing shade for grazing dairy cows during the summer in Sweden.
Two groups of lactating Swedish Red dairy cows (n=15 per group) were kept on pasture.
VVA-strategier för avgastemperaturhöjning på en HD-Dieselmotor
Regulations on the exhaust emissions of HD-diesel engines are becoming more and more stringent, and therefore, emission after-treatment systems are commonly used. These systems rely on catalytic conversion of NOx,CO , and HC emissions, and are thus dependant on temperature. At low load of the engine, exhaust temperatures are not sufficient for the after-treatment components. Therefore, means to increase the exhaust temperature while maintaining low emissions and fuel consumption are needed.The focus of this project has been to develop strategies for the lift profiles of exhaust and intake valves in the engine, with the goal to raise exhaust temperature in combination with low emissions and fuel consumption. The strategies have been tested in a single-cylinder research engine equipped with a hydraulic variable valve actuation system.
Undersökning av sambandet mellan strålningstemperatur och NDVI i Sahel
Several studies have analysed the relationship between Normalised DifferenceVegetation Index (NDVI) and radiative surface temperature. A main goal for moststudies have been to find the best method for carrying out land cover classificationsand to study land cover changes, based on a combination between the twoparameters. Since atmospheric components have a significant influence on bothparameters, most applications were based on multi-temporal data. The quality of theindividual values in such a combination is improved, but the biophysical justificationis uncertain. This study presents a different method, based on only the combination ofvalues that have been registered the same day and about the same time of the day.125 daily images of NDVI and 250 images of radiometric temperature were used inorder to analyse the relationship between (1) NDVI and radiative temperature and (2)NDVI and relative temperature difference between early morning and mid-day.Results between NDVI and radiative temperature show a significant negativecorrelation on areas where a distinct growing season develops, and a strong positivcorrelation where vegetation is abscent throghout the season.
Förskolans inomhusmiljö ur ett genusperspektiv
My essay is about me and my colleagues who have come to realize that maybe we are stuck in old habits when it comes to preschool indoor environment from a gender perspective. The insight has enabled us now face the challenge of how to deal with and move forward with gender issues and the indoor environment. The reviews between us educators differ greatly, making it difficult start of a process of change, or development, of previous work in the preschool. The difficulties of working with gender in preschool is that we do not know how teachers influence or shape the children. We educators controls many times the children, both consciously and unconsciously and sometimes benevolence tend to instead become a takeover.
Hälsoeffekter från trafikbuller vid Bäckegatan
The purpose of the study is to investigate the possible effects of an unstable ventilation system and its influence on energy use and thermal comfort. The report also explores how qualified personal working with HVAC view and handles system control.In order to meet the requirements in energy efficiency and a comfortable indoor climate control regulation is a prerequisite. With optimized increased complexity of the climate systems, it becomes more challenging to control the system and the risk of unstable control increases. No previous studies about what affect an unstable system can have on energy use and thermal comfort have been found.The report is based on several tests were the controlling variable has been increased until the system becomes unstable. Two different types of unstable systems have been investigated.
Påverkan på energianvändning och termisk komfort vid reglerinstabilitet
The purpose of the study is to investigate the possible effects of an unstable ventilation system and its influence on energy use and thermal comfort. The report also explores how qualified personal working with HVAC view and handles system control.In order to meet the requirements in energy efficiency and a comfortable indoor climate control regulation is a prerequisite. With optimized increased complexity of the climate systems, it becomes more challenging to control the system and the risk of unstable control increases. No previous studies about what affect an unstable system can have on energy use and thermal comfort have been found.The report is based on several tests were the controlling variable has been increased until the system becomes unstable. Two different types of unstable systems have been investigated.
Ekonomi i Passivhus : En studie av två verkliga byggnader
The aim of this report was to investigate the economy of passive houses. The work was focused on economy in total and on the economy of different components such as windows, insulation, heat exchanger and the air tightness of the climate shell. No attention was paid on the comfort factor or to the impacts on the environment.Two houses, aspiring to be passive were chosen; A big one and a small one. Hence, comparisons considering the size of the building have been possible to do as well.The comparisons were made by calculating ?break even? between two concepts; passive and BBR- concept.
Ångsterilisering av morötter. Infekterade med Lactobacillus plantarum.
The purpose of the project was to exam steams ability to sterilize carrots infected withLactobacillus plantarum. The project was a cowork with Brämhults Juice AB. They hadobserved an increase of Lactobacillus in the production of carrot juice during the summer. Tokeep the flavour of fresh fruits, the juice is treated carefully with heat. This means that thejuice only stays fresh for a few days, around two weeks for an unopened package and threedays for an opened package.In an attempt to remove the remaining Lactobacillus of the carrots, steam is tested as an extrastep in the production of juice.
Spillvärmeåtervinning
SAPA´s resource of waste heat is the basis for this thesis to investigate the possibility of energy assets in their cooling water and possible uses for it. The energy in the waste water is greater than the current need which has three uses which are (1) heating the factory, (2) converting liquid propane to propane gas and (3) local domestic heating. The average energy load that is available is 1, 7 MW and the average temperature in the cooling water is 41°C. The total energy load at dimensioning out side temperature is approximately 1,6 MW for the three current uses. The temperature is currently too low to be used directly in the existing systems so an upgrade is needed.
OMBYGGNAD AV TRAFIKPLATS : Ekhagsmotet i Jönköping
We have the tradition in Sweden to build villas and houses with a wooden framework. It has become natural for us because we have so much forest in our country. Building with wood has advantages, it is easy to process, but also disadvantages, as it is sensitive to moisture.Finland has long made use of the thermal blocks to build villas. It is a type of bricks that are a bit like a sandwich element, with a core of EPS and concrete on both sides of the core material. The concrete is hollow, so that after the walls has been bricked up you pour concrete into the hollow bricks.The issue of this report is to find out if concrete can be an alternative to wood as framework material in villas.