Sök:

Sökresultat:

876 Uppsatser om Improvement of the wastewater - Sida 2 av 59

Membranbioreaktorteknik- en framtida lösning på Lundåkraverket? : Membrane bioreactors- A future solution at Lundåkra wastewater treatment plant?

Membrane bioreactors (MBR) combined with biological phosphorous treatment (Bio-P) has been investigated if that could be an alternative to the future expansion with conventional active sludge treatment at Lundåkra wastewater treatment plant (WWTP) in the proximity of Landskrona, Sweden.The results showed that the surface demand in the biological treatment will be reduced with 67% with the MBR-alternative compared to a conventional activated sludge process. The nutrient removal in the MBR-solution was decreased or unchanged for nitrogen-, phosphorous- and organic parameters. However, the energy demand will increase with an estimated cost of approximately 1 million SEK annually. Moreover, the extra chemical consumption is estimated to cost 370 000 SEK annually.The disturbances caused by filamentous bacteria such as sludge dispersal could be resolved with MBR-technology because the membranes are not affected by these organisms. The Bio-P process combined with MBR-technology works if the wastewater recirculates from the membranes to an aerobic zone.In the proposal, there will be a new pre-treatment step, for instance hole screens.

Älgarås avloppsreningsverk- studie och metodisk felsökning av en biobädds BOD-rening

Wastewater contains biodegradable materials, which are often measured as BOD7.Trickling filters are sometimes used as a purification step for BOD-reduction. Atrickling filter is a tower, which is filled with a carrier material. Microorganisms growon the carrier material in the form of a biofilm. This biofilm consists mostly of bacteriathat purify water from BOD.In Älgarås? wastewater treatment plant the water is purified by a trickling filter.However the treatment plant has difficulties reaching the emission requirements forBOD.

Hydrolys av primärslam för förbättrande av biologisk fosforreduktion vid behandling av hushållsavloppsvatten [Hydrolysis of primary sludge for enhancement of biological phosphorus removal in household wastewater]

Hammarby Sjöstad is a new district of southern Stockholm built with focus on reduced environmental impact by recirculation of materials and sustainability. The environmental goals aim to cut the water consumption by half and a separate storm water treatment. Thus, the wastewater will be more concentrated and will originate from the households only. The Sjöstad project includes the idea of a local treatment plant for the household wastewater. To evaluate this possibility, Sjöstadsverket, an experimental treatment plant was constructed.

Källsorterade systems påverkan på avloppsreningsverk : växthusgaser, energi- och resursanvändning i modellstudie

The aim of this study was to evaluate the effects on a simulated wastewater plant regarding GHG emissions and use of energy and resources when implementing source separated wastewater systems. The effects were studied for different restrictions of effluent quality and for different temperatures on the influent. The simulation model BSM2G calibrated for Käppala wastewater treatment plant was used. The task was executed by simulating nine different scenarios with an increase in influent load from new connections equivalent to 3, 10 and 30 % of the present connections. These new connections were served by conventional, urine separated or black water separated systems.

Total organic carbon (TOC) and chemical oxygen demand (COD) - Monitoring of organic pollutants in wastewater

Total organic carbon (TOC) and chemical oxygen demand (COD) are two methods used for measuring organic pollutants in wastewater. Both methods are widely used but the COD method results in production of hazardous wastes, including mercury.The purpose of this study was to validate the method TOC that will replace COD and find a factor to convert TOC to COD. In this study 26 samples were analyzed from four sewage treatment plant in the municipality of Enköping.The results show that the COD method could be replaced by the TOC method.The factor for COD/TOC was between 3.1 - 3.3. Both methods will be used in parallel until 2013 when it will be forbidden to use the COD analysis..

Grus i maskineriet : en fallstudie om förbättringspotential

Grus i maskineriet ? en fallstudie om förbättringspotentialVäxeln AB, a company that provide sales, service and repair of industry gears, has contacted the authors of the essay and asked us to investigate in which areas of the company that has improvement potential. Persistent improvement is a recurring and up-to-date issue that many business leaders not put enough resources on. A big problem in many companies is the issue that there is no comprehensive view and therefore some of the workers tend to not follow the routines that are required for the whole system to work.The goal with the essay is to give Växeln AB advice on to which areas in the company that have improvement potential.We have used a qualitative method with mainly semi-structured interviews which has led to an inductive approach. 13 co-workers that work in different areas of Växeln AB have taken part in the interviews.

Näringsbelastning på en anlagd våtmark från åker, skog och enskilda avlopp :

This work is a part of the project ?Våtmarker i odlingslandskapet ? uppföljning av miljömålen? (Wetlands in arable land ? following-up of the environmental goals). The main objective with this project is to study nitrogen and phosphorus retention in a constructed wetland by using mass balance calculations. Continuous measurements of nutrients and water flow through the inlet and the outlet of the wetland are made. However, substantial amounts of nitrogen and phosphorus were assumed to reach the wetland with a drain-pipe transporting wastewater from nearby houses (10 persons).

Textilindustrins avloppsvatten och avloppsslam ur ett miljöperspektiv : Underlag för internationella riktlinjer inom projektet Sweden Textile Water Initiative

The aim of my thesis is to obtain knowledge of textile wastewater and textile sludge from an environmental perspective, which can be used as a basis for the  ?Sweden Textile Water Initiative? guidelines for a sustainable sludge management. In my study I have mainly focused on textile dyes, salts and metals and their routes during wastewater treatment.This paper is partly a literature review, which I began by identifying the pollutants discharged from each textile process. Then I studied wastewater and sludge quality, environmental aspects, possible treatment and recycling methods. I have also tried to find existing type of guidelines in order to make comparisons.

Analys av framtidens system för hantering av avloppsvatten och matavfall i Eskilstuna

Wastewater treatment is increasingly controlled by the Swedish environmental quality objectives, adopted by the Swedish parliament. There is a need for a sewage system that can fulfill stringent requirements concerning the environment, recycling and resource use and hygiene. Additional environmental aspects in recent years are the impact of climate change, new knowledge about the effects of pharmaceuticals in water, the need for improved wastewater treatment and increased recycling of nutrients to agriculture. This report has, from a future scenario of the year 2050, analyzed seven different systems for wastewater treatment and treatment of compostable biowaste from households in Eskilstuna. A future scenario was chosen based on that within a forty year period new challenges may arise which can result in higher demands on sewage treatment than those we see today. Another reason why the future scenario was established is that changes in wastewater treatment systems are slow to establish. The analysis is mainly focused on the economical aspects but environmental aspects such as emissions to receiving waters and potential recycling of plant nutrients has also been evaluated briefly.

Första linjens chefers skattning av sina ledar- och chefsegenskaper samt strukturell empowerment före och efter utbildningsinsats för chefer inom kommunal verksamhet.

The purpose of this study was to examine whether there were any differences in how first-line managers within   municipal care   rated their management leadership qualities, and structural empowerment before and after the course in "leadership, learning and improvement". The study had a quasi-experimental design and 64 managers participated. There was a significant improvement in the LaMI factor ?Achievement orientation?, after participation in the course "leadership, learning and improvement". In other factors, there was no significant difference before and after training.

Systemidentifiering och reglering av en luftningsbassäng på ett reningsverk

A wastewater treatment plant has the task to refine the wastewater from substances that should not be released into the environment. The decomposition process can, in a simple way, be described as follows: micro-organisms breathe oxygen and eat unwanted substances. The environment in which the micro-organism lives is known as sludge and the correct amount of oxygen available in the sludge is important for the decomposition to be effective. The oxygenation of the sludge alone stands for about 30% of the plant?s energy consumption.

Hydrauliken i Ångersjöns fosforfällor : bestämning av flödesvägar och åtgärdsförslag för optimal fosforbindning vid avloppsrening med reaktiva filter

Discharge of untreated wastewater leads to unnaturally high levels of nitrogen and phosphorus in rivers, lakes and the sea, which results in unbalanced ecosystems with eutrophication and lack of oxygen. Part of the phosphorus in surface waters is coming from on-site wastewater treatment from scattered households with unsatisfactory purification. Blast furnace slag is a by-product from iron production, and has in laboratory trials showed good phosphorus binding capacity. To test blast furnace slag as a reactive filter media for phosphorus separation in a full scale experiment, a wastewater treatment plant has been built behind the picnic area at Ångersjön alongside the road E4 in central-eastern Sweden. The plant contains two parallel lines, one with blast furnaces slag and the other with Filtralite-P as phosphorus sorbent. Both filters have showed decreasing phosphorus purification effect with time in spite of a low wastewater load.

Analys av system för rening av avloppsvatten i en anaerob membranbioreaktor

The most common way to treat wastewater in Sweden today is by a combination of an activated sludge process and a chemical treatment. These processes are not very energy efficient and may not be the most environmentally friendly. That is why it is interesting to evaluate new alternative methods to see if they can be less harmful to the environment and help to a lower resource consumption. New techniques are tested in a pilot installation at Hammarby Sjöstad, Sjöstadsverket. To be able to evaluate these techniques in a wide perspective system analyses are conducted where different impacts can be considered, advantages and disadvantages in the systems.Five system structures for water treatment have been constructed in Matlab/Simulink in this study.

Skolutveckling med ett neurodidaktiskt perspektiv : En kvalitativ studie med skolledare, specialpedagoger och en utvecklingsledare.

AbstractThe overall purpose of this thesis was to investigate to what extent new research findings, in neuroscience and learning, may be useful in a school improvement context. In a qualitative interview study combined with questionnaire, we have investigated the approach to school improvement that exists in a municipality. Informants have been head teachers in preschool and primary school, special education teachers in a student health team and a development manager. The outcome of the study showed that all of the study participants, all of which have a formal mandated to work for school improvement occurs. It also shows that informants, according to their professional position, express different goals when relating to school improvement.

Avskiljning av ammoniumkväve och fosfatfosfor i reaktiva filtermaterial : skak- och kolonnförsök

In Sweden more than 400 000 private households have not yet sufficient wastewater purification. These effluent is considered as an increasing problem and many onsite purification methods have been studied. In this investigation, the method of reactive bed filters have been tested by column and batch experiments. Five different kinds of filter materials with reactive surfaces have been studied concerning their capacity to absorb ammonium and phosphorus from wastewater. The materials that were examined are Filtra N, wollastonite Filtra P, blast furnace slag and Polonite®.