Spänningsstyrd underfrekvenslastfrånkoppling i elektriska kraftsystem
This report is a Master?s Thesis performed by Andreas Adolfsson and David Jacobsson atChalmers University of Technology. The purpose of this master?s thesis is to evaluate anew method for load-shedding, the voltage controlled underfrequency load-sheddingdeveloped by ABB. This report presents a comparison between conventionalunderfrequency load-shedding and this new method for load-shedding.
Diesel Dubbelbränsle Teknologi
The work covered in this report includes a literature study of the diesel dual fuel technology(hereinafter referred to as DDF). The literature study covers earlier work that has been doneregarding the use of compressed natural gas (CNG) and diesel in a DDF system. Moreover a onecylinder research diesel engine was fitted with a CNG fuel system for experimental testing. Theinstallation of the engine and the test cell is described. Results from the tests are presentedcovering emissions, heat release and pressure traces from the DDF-concept.During the literature study it was found that most research was related to heavy duty dieselengines.
Persontäthet vid utrymningsberäkningar : Köpcentrums persontätheter
The aim of this study is to evaluate whether the value of occupant load is over or under estimated when the Swedish general value for department stores, 0,5 person/m2, is used for dimensioning shopping centers. The data that was analyzed derives from seven shopping centers and one department store. A conservative method was used to calculate the occupant load factor. The analysis shows that two groups can be discerned: one group that is characterized by a lower occupant load factor that does not exceed 0,3 person/m2, and one group with a higher occupant load factor. Shopping centers with a higher occupant load factor are located centrally in large urban areas.
Restvärmeåteranvändning från absorptionsvärmepumpar : en kartläggning av möjligheter och begränsningar vid Vattenfall Värme Uppsala Block 5
Vattenfall district Heating power plant in Uppsala produces district cooling with absorption heat pumps which leads to a large amount of waste heat that has to be cooled with evaporative cooling towers. The Environmental Court has ordered Vattenfall to survey the possibilities to recover the heat, which is the focus of this thesis.The study begins with an overview of the system, and conditions and limitations for waste heat recovery is examined. In the next step alternatives to recycle the heat is evaluated, either by direct recovering or by upgrading.First, the technical possibility of each alternative is discussed, and then the operation time and the amount of recovered heat is calculated. Those alternatives which are possible are brought further to an economic analysis.The cost of investment for each alternative constitutes the basis for a present value analysis. The results are put together in a table where the total amount of recovered heat is compared with the present value for the different alternatives.
Analys av off-design prestanda för ett absorptionskylsystem
This master thesis project at KTH is performed in the Mechanical and Aerospace Engineeringdepartment at University of Florida (UF). The thesis is a small part of a gas turbine researchproject where a vapour absorption refrigeration system (VARS) and a high pressure regenerativeturbine engine (HPRTE) are integrated together. The main objective is to build a computermodel of the VARS. The computer model is supposed to be used to analyse the off-designperformance of the VARS and should also be easy to integrate as a subroutine in a more complexsystem model. To model the VARS some knowledge of the absorbent/refrigerant mixture had tobe well known, in this case a mixture of ammonia and water.
Kartläggning av material flödesflaskhals i ICA butik.
In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.
Datormodellering av en värmelagrande betongväggs inverkan på det termiska klimatet i ett växthus
This report describes the building of a computer model that makes it possible to simulate the thermal climate in a greenhouse. The computer model is built on the physical theory of heat exchange that occur in a greenhouse, such as radiation and convective heat exchange. The model also includes the heat storage that is active in a greenhouse.The computer model is used to simulate the thermal climate in a greenhouse under three periods, winter, spring and summer. It also investigates which effect a concrete wall has on the thermal climate in a greenhouse. The purpose of putting a concrete wall in the greenhouse model is to investigate the possibility to store heat during the day and then use this heat when the temperature drops during the night.The result from the simulations shows that a concrete wall levels the big difference in temperature that normally occurs under a day in a greenhouse.
Värmepumpars inverkan på elkvaliten
Modern technology and fast development of heat pumps, the hunt for savings in energy consumption and the strive for environmentally friendly energy sources, convenience, and financial profit, have made heat pumps a reasonable alternative for the heating of houses.When the heat pump starts it will consume a considerable amount of current, which may result in a short-lived voltage-drop if the power grid is weak compared to the start-up current.The company Fortum Distribution which owns and administrates electrical network is interested in an investigation that deals with heat pumps affect on the quality of electricity.The purpose of this investigation is to study fast electrical fluctuations (flicker) as a result of start-up currents for single as well as multiple heat pumps on the same electrical station and from this evaluate whether there will be any problems installing heat pumps..
Värmestyrning I Handske
This rapport is result of a project. The purpose of which was to design a circuit that is used in a heat glove. The heat glove is the technical aid which provides heat inside a glove.It is specially suited for old people who have problems with cold hands because of decreased blood circulation.There already was an old circuit in the glove that gives a constant current which develops heat from battery to glove through a circuit. The temperature is between 32 and 34 degrees.The problem with the existing circuit was to regulate the temperature. There is only on/off switch and there is no way to adjust desirable value of the temperature.In order to solve the problem the old circuit was investigated.
Effektivare energianvändning på Totebo AB
The main goal with this thesis report was to come up with ideas of how to make the use of energy more effective and thus save money for the company.First a survey was made to find out where and how the energy consumers were divided within the company. The results were then used in calculations to find out how much money that could be saved and how long it would take to get back the investments.There is a big potential in saving money by recovering heat from the UV-lamps with a heat exchanger. It would also even out the pressure in the factory which is a source to heat loss and a cause for discomfort amongst the employees. It?s possible to save 105 000 kr in a year and the money needed for the investments is 600 000 kr.By using the recovery air more effectively the company could save up to 250 000 kr a year in lowered heat purchases, but this would require the use of automatic dampers.If you reschedule the running times for the wood chipper and invest in some kind of load management, for example Sydkraft?s ?Energidirigent? you can save at least 42 000 kr.
Värmeåtervinning på förskolan Rymdattacken 1 : En jämförelse av värmeväxlare
In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.
Samkörning mellan värmepumpar och fjärrvärme : Bostadsrättsföreningen Bogården
This diploma work covers an investigation over the heat - and hot water systems of thetenant-owner's association, Bogården. The heat - and hot water needs of Bogården aresatisfied by both district heating as well as three heat pumps. Implemented investigationshows that the heat pumps are not used in a profitable way. Apart from that, the reservepossibilities are small. There is also a risk of the growth of Legionella bacterium in thehot water system.Since the heat pumps are already installed, HSB-Gävleborg (responsible for Bogården)has a wish to investigate possible proposed actions for optimization of existing plant.After completed investigation, a new proposed action is presented.
Spillvärmeåtervinning ur kylvattensystemet ismältverket på Sapa Profiler AB i Sjunnen
The smelting process at Sapa Profiler AB in Sjunnen generates large quantities of waste heat which is absorbed by the cooling water when the aluminum is cooled down. This paper is the result of a Master?s Degree Project aiming to present the conditions for recycling the waste heat. The cooling water absorbs the heat from the aluminum at an average rate of 600 kW and the paper shows that it can be used to replace electrical power consumption for heating the production plant?s facilities.
Heat Maps : En metod för att uvärdera banor
Denna rapport har undersökt om game metrics genom heat maps kan användas för att hitta en choke point i en bana gjord till spelet Team Fortress 2. Game metrics och kvantitativa metoder erbjuder ett objektivt och nästan automatiserat alternativ till kvalitativa metoder när det kommer till balansering. En bana har konstruerats med en choke point och har speltestats för att generera en heat map. För att undersöka om det går att hitta en choke point med hjälp av en heat map så har en enkät gjorts där respondenter bads hitta choke pointen med hjälp av den heat mapen som genererades från speltestningen av banan. Alla respondenter lyckades hitta mitten av choke pointen med hjälp av heat mapen. I framtiden skulle arbetet kunna utökas genom att undersöka om användandet av bottar eventuellt skulle helt kunna automatisera balanseringsprocessen. Det skulle också gå att undersöka hur olika klasser rör sig i en bana..
Terapeutegenskaper och allians i utbildningsterapi: En intervjustudie
The working alliance between therapist and client has been proven important for the treatment outcome in psychotherapy, as well as the therapist?s characteristics. The aim of the current study was to examine the experience of important characteristics when forming a working alliance, among psychotherapy trainees. Eight psychotherapy trainees at Umeå University were interviewed and the material was analyzed using Interpretative Phenomenological Analysis (IPA). Characteristics described as positively impacting the working alliance were interested, empathic, warm, genuine, secure, flexible and accepting.