Sök:

Sökresultat:

656 Uppsatser om Heat Pumps - Sida 3 av 44

Kartläggning av material flödesflaskhals i ICA butik.

In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.

Datormodellering av en värmelagrande betongväggs inverkan på det termiska klimatet i ett växthus

This report describes the building of a computer model that makes it possible to simulate the thermal climate in a greenhouse. The computer model is built on the physical theory of heat exchange that occur in a greenhouse, such as radiation and convective heat exchange. The model also includes the heat storage that is active in a greenhouse.The computer model is used to simulate the thermal climate in a greenhouse under three periods, winter, spring and summer. It also investigates which effect a concrete wall has on the thermal climate in a greenhouse. The purpose of putting a concrete wall in the greenhouse model is to investigate the possibility to store heat during the day and then use this heat when the temperature drops during the night.The result from the simulations shows that a concrete wall levels the big difference in temperature that normally occurs under a day in a greenhouse.

Värmestyrning I Handske

This rapport is result of a project. The purpose of which was to design a circuit that is used in a heat glove. The heat glove is the technical aid which provides heat inside a glove.It is specially suited for old people who have problems with cold hands because of decreased blood circulation.There already was an old circuit in the glove that gives a constant current which develops heat from battery to glove through a circuit. The temperature is between 32 and 34 degrees.The problem with the existing circuit was to regulate the temperature. There is only on/off switch and there is no way to adjust desirable value of the temperature.In order to solve the problem the old circuit was investigated.

Inventering av värmelager för kraftvärmesystem

When a combined heat and power plant produces heat and power it often faces a deficit of heat load during the summer or other periods of time. This heat is often unnecessarily cooled away or the power production has to be reduced or shut off. If it is possible to store heat from periods with low heat demand to periods with high heat demand one can get many benefits. Among these benefits are: increased power production, decreased operation with partial load, uniformly distributed load.To be able to store heat in situations like this long-term thermal heat storages are needed. In this thesis five different types of stores are presented: rock cavern storage, tank storage, pit water storage, borehole storage and aquifer storage.

Värmeåtervinning på förskolan Rymdattacken 1 : En jämförelse av värmeväxlare

In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.

Spillvärmeåtervinning ur kylvattensystemet ismältverket på Sapa Profiler AB i Sjunnen

The smelting process at Sapa Profiler AB in Sjunnen generates large quantities of waste heat which is absorbed by the cooling water when the aluminum is cooled down. This paper is the result of a Master?s Degree Project aiming to present the conditions for recycling the waste heat. The cooling water absorbs the heat from the aluminum at an average rate of 600 kW and the paper shows that it can be used to replace electrical power consumption for heating the production plant?s facilities.

Det energiproducerande huset

We are heading towards a huge switch of how energy is produced with fossil fuels being replaced by renewable energy sources. It is not difficult to replace the energy you use in the house and there is no need for futuristic technology. There are already many established products on the market such as high efficiency vacuum solar collectors, Heat Pumps & small wind power stations that can supply the energy being used in a house. The company Sol & Energiteknik SE AB in Huskvarna has many different products which can reduce the need for an outside energy distributor. An average house in Sweden uses 15 000 kWh for heating, 5000 kWh for tap water and 5000 kWh for electricity.

Heat Maps : En metod för att uvärdera banor

Denna rapport har undersökt om game metrics genom heat maps kan användas för att hitta en choke point i en bana gjord till spelet Team Fortress 2. Game metrics och kvantitativa  metoder  erbjuder  ett  objektivt  och  nästan  automatiserat  alternativ  till kvalitativa metoder när det kommer till balansering. En bana har konstruerats med en choke point och har speltestats för att generera en heat map. För att undersöka om det går att hitta en choke point med hjälp av en heat map så har en enkät gjorts där respondenter   bads   hitta   choke   pointen   med   hjälp   av   den   heat   mapen   som genererades från speltestningen av banan. Alla respondenter lyckades hitta mitten av choke  pointen  med  hjälp  av  heat  mapen.  I  framtiden  skulle  arbetet  kunna  utökas genom  att  undersöka  om  användandet  av  bottar  eventuellt  skulle  helt  kunna automatisera  balanseringsprocessen.  Det  skulle  också  gå  att  undersöka  hur  olika klasser rör sig i en bana..

Energieffektivisering på Skutskärs Bruk : Varvtalsstyrning till utvalda pumpenheter på Blekeri 4

In modern society in terms of economics and environmental impact, it is important to ensure that a company is as energy efficient as possible to reduce the amount of energy used. About 10 TWh of electricity used annually to pump drives in Swedish industry. Therefore, pumping system has great potential for energy savings.The objective of this report was to determine how much energy and money that can be saved with the insertion of variable speed drive to six pumps on Bleach plant 4 in Skutskär Mill. The work was performed with electrical measurements during one week, analysis of pump curves and the compilation of production data over a year.The results show that four of these six pumps were profitable and yielded an annual saving of 1172 MWh of electricity and 560 000 SEK. With an economic lifetime of 10 years and a discount rate of 6.8% the final result for the entire life-cycle savings became 3 355 000 SEK.

Potential för värmeåtervinning från mjölkkylanläggningar

The present climate discussion has made energy efficiency an interesting topic. Saving energy does not only help the climate but also saves money for the energy consumer. The purpose of this thesis was to examine the potential of heat recovering from milk cooling. Two milk farms, one with voluntary milking system, VMS, and the other with conventional milking system was used to measure interesting temperatures and electricity consumptions. The numbers were used both to do theoretical calculations and to construct a SIMULINK model. To calculate the potential for heat at milk farms theoretical calculations were made in MATLAB using a reference farm with different combinations of heat recovery and pre cooling. The farm was assumed to keep a dwelling house with the annual heat consumption 18165 kWh.

Genetisk variation i brunststyrka hos svenska mjölkkor :

When cows in Sweden are inseminated the heat strength is reported to the Swedish milk-recording scheme and AI scheme. Cows that show strong signs of estrus are desirable and the trait is included in the Swedish breeding goal. A strong heat makes it easier to inseminate at the right time and to avoid long and expensive days open. Since ten years the heat strength is scored from one to five by the farmer and reported to the milk-recording scheme and AI scheme. Earlier the score was from one to three and the decision was made by the AI technician.

Social hållberhet genom medborgardialoger : exemplet Husby

Understensho?jden is Stockholm's largest eco-village which was built in the early 1990s with the vision of enabling ecological living for people. However the ecovillage is no longer considered as environmentally friendly because of its relatively high energy consumption, and non-updated energy system. The purpose of this study is therefore to investigate how Understensho?jden should reduce their energy consumption and upgrade its energy system by using Blower-Door, IR-camera and Design Builder.

En studie av Uppsala stads värmeö

The urban heat island is an area restricted to a city center where the temperatureis higher than its surrounding environment. The greatest temperature difference isfound at night when the weather is calm and the sky is clear of clouds. There are twomajor causes behind this phenomena and the first one is the use of energy forheating of houses. The heat leaks through the walls of the buildings and warms upthe surrounding mass of air. The second one is the use of building material whichstore the suns radiation on daytime and releases the heat during night.

Värmeåtervinning ur spillvatten : En utredning av möjligheterna med spillvattenvärmeväxlare

The purpose of this report is to investigate the possibilities with drain water heat recovery (DWHR) in residential buildings. Information and relevant theory has been collected and summarized in this report. Calculations have been done for given scenarios to evaluate profits. DWHR heat exchangers use simple technology and have long life-time. The heat exchanger is connected to outgoing drainage pipe and incoming cold-water supply so countercurrent flow is accomplished.

Skalkonstruktion : Med inriktning mot hållfasthet och dämpning av ljud

The sound part is mainly practical and is dependent on concepts that have been tested through measuring with a sound level meter. The design part is more theoretical and has been verified with CAD models and finite element analysis.With a sound damping hood on the compressor the sound level is reduced with up to four dB. An optimized absorbent for the compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents.By changing the today?s insulation to the heat water tank to a form of polystyrene polymer insulation the weight from the heat pump above can be transferred to the stable heat water tank.

<- Föregående sida 3 Nästa sida ->