Norrkila arena : visuell beskrivning av arena
A home for elderly is planed to be built at Zakrisdal, Karlstad, Sweden. The heat source for the building was at the time not determined. In order by the local government of Karlstad this report is meant to examine if the need of heat could be provided only by solar heat combined with a seasonal heat storage. The problem to solve is, if the need of heat from the home for elderly is provided from only solar heat, whitch dimensions of the solar collectors and the storage is needed?.
Spillvärmeåtervinning
SAPA´s resource of waste heat is the basis for this thesis to investigate the possibility of energy assets in their cooling water and possible uses for it. The energy in the waste water is greater than the current need which has three uses which are (1) heating the factory, (2) converting liquid propane to propane gas and (3) local domestic heating. The average energy load that is available is 1, 7 MW and the average temperature in the cooling water is 41°C. The total energy load at dimensioning out side temperature is approximately 1,6 MW for the three current uses. The temperature is currently too low to be used directly in the existing systems so an upgrade is needed.
Värmeåtervinning ur spillvatten i befintliga flerbostadshus
Drain water heat recovery is an uncommon measure in multi-unit residential buildings. There istechnology available for the purpose but the knowing and experience of the heat recovery systems islittle. The purpose of this thesis is to evaluate the future potential of drain water heat recovery inmulti-unit residential buildings.A major part of the multi-unit residential buildings in Sweden were built during modernismen andrekordåren (1940?1975). Many of the buildings have worn out drain and water supply systems andmany are in need of a general refurbishment.
Energieffektivisering i ett verkstadsföretag : En analys av energibesparande åtgärder samt uppvärmnings- och kylsystems driftkostnader och koldioxidutsläpp
The energy use in a workshop company has been examined in this work in order to find areas for energy efficiency improvement. The combined oil and electricity heating in the company were compared with other alternative heating systems including cooling of the premises in following combinations:Ground source heat pump for heating and coolingDistrict heating and absorption coolingDistrict heating and low temperate surface water coolingEnergy use, operation costs and carbon dioxide emissions were calculated for the current heating systems and the three alternatives including cooling. The ground source heat pump for heating and cooling decreases bought energy with 34 MWh annually compared to current heating only. The district heating and low temperate surface water cooling has the largest reduction of operation cost and carbon dioxide. The operation cost decreases with 42 kSEK and the carbon dioxide with 43 metric ton CO2 annually.
Fjärrvärme, vad annars? : Fjärrvärme och dess alternativ
AbstractBackgroundThe Swedish district heat market of today is a subject being discussed regarding the reasonableness of the heat district supplier?s price settings. The issue is currently on a government level where a new investigation is being executed at the time of writing. Many real estate owners are growing tired of the situation where the heat district suppliers are taking advantage of their monopoly position, thus feeling that the price of district heating has been increasing far too much for many years. The market can be described as a natural monopoly because the real estate owner has no possibility to choose another supplier if they are unsatisfied with the present.
Expansionsmaskiner istället för strypventiler - en effektivisering
In Uppsala CHP Plant, there are six pressure reducing valves to reduce the pressure from 15 to 3 bars, before six absorption heat pumps. During the process the energy is conserved but losses occur in form of exergy. The aim of this thesis is to reduce the losses of exergy. This can be done by letting turbines replace the pressure reducing valves.In this thesis an investigation has been done of the conditions today, the conditions after the change from pressure reducing valves to turbines and a comparison of three different types of turbine solutions. The three examined solutions are one turbine, several helical screw expanders and several small turbines in parallel with asynchronous generators.The six absorption heat pumps have been divided into two groups; one group of four and one group of two absorption heat pumps.
Vibrationsdämpning av värmepump
Thermia Värme AB is one of the market leading manufactures of heat pumps. In order tomaintain this position, the company wants to improve the vibration characteristics of theirproducts. The aim of this thesis is to develop product design changes that lead to a reductionof vibrations in the heat pump Thermia Diplomat 8.The main cause for vibrations in the system is flow pulsation and mechanical forces inducedby the scroll compressor. Vibration is transmitted through the compressor piping and receivedby the heat exchangers, from where it is further transmitted to the connection points for theradiator and heat source circuits.A number of design changes in order to improve the vibration characteristics have beenevaluated through calculations and practical experiments. The changes have included thecompressor and heat exchanger mountings, the compressor suction and discharge line pipingand also pulsation dampening.The results of the experiments show that the vibration levels in the connections for the heatingand brine circuits can be decreased strikingly through changes in suction and discharge linepiping.
Luft/luftvärmepump : - Med möjlighet till återvinning
Sweden has long had access to low electricity prices due to the wide availability of hydro and nuclear power. This has now changed because of today's rising electricity rates resulting in increasing heating costs for properties, especially in the properties with electric heating systems."Ankaret" is a parish for "Svenska Alliansmissionen", which is located at "Gullbrannagården".The parish has installed electrical radiators and an exhaust ventilation system that makes the energy demand high due to the large ventilation flows. The building was built as the price of electricity was still low and would reduce energy use today by combining its heating system with an air/air heat pump. The heat pump delivers more heat into the room than the electrical energy that it uses. This lowers the electricity needs.
Hur byggnadsdetaljer ändrar fasadens uttryck
An energy study has been performed on two blocks in an area called Gävle Strand. The buildings are owned by a tenant-owner?s association called brf Carolina and were built by the company Skanska 2008. The builder as well as brf Carolina are pussled by the fact that electricity use is higher than expected while heating is less. Skanska is also very interested in finding out how much heat recovery from stale exhaust air through a geo-thermal heat pump is contributing to the general heating requirement and energy balance in four out of the ten buildings located on the properties.To find possible answers to the higher electricity use a literature survey on user behaviour was conducted.
Konceptstudie av Waste Heat Recovery System på Tunga Fordon
In today?s fast growing and closely connected society, a reliable and energy efficient transportation system is more than ever desirable. Nowadays the significant part of the transportation sector?s energy demand is supplied by fossil fuels.Improving energy efficiency in combustion engines will result in reduction of fuel consumption and CO2 emissions. A modern internal combustion engine has an efficiency of 30-45 %, where the most energy loss occurs as result of heat losses in the exhaust and cooling systems.
Prestandaförändringen hos en bergvärmeanläggning efter fem års drifttid
The aim of this report was to do a case study at a geothermal heating system which has been in operation for about 5 years, and study if its performance has changed during this period of time. A literature study about the processes involved was also done in purpose of background knowledge.The tenant-owner?s association Duvan at Petterslundsgatan in Uppsala installed year 1999-2000 a geothermal heating system. The purpose of this installation was that they hoped it would lead to a smaller usage of district heating which would lead to a reduction of the heating expenses for their buildings. The geothermal heating system consists of 19 energy wells and 4 geothermal heat pumps, and it is one of the first systems of that size in the region of Uppsala.
Analys av energianvändningen i kvarteren Carolina och Jenny : en fallstudie
An energy study has been performed on two blocks in an area called Gävle Strand. The buildings are owned by a tenant-owner?s association called brf Carolina and were built by the company Skanska 2008. The builder as well as brf Carolina are pussled by the fact that electricity use is higher than expected while heating is less. Skanska is also very interested in finding out how much heat recovery from stale exhaust air through a geo-thermal heat pump is contributing to the general heating requirement and energy balance in four out of the ten buildings located on the properties.To find possible answers to the higher electricity use a literature survey on user behaviour was conducted.
Jämförelse av frånluftsvärmepumpar
In order to reach the environmental targets, set up by the EU, there are many measures taken to make Sweden more energy efficient. In the housing and real estate sector, an installation of an exhaust air heat pump that reuses the heat in the exhaust air in order to lower the amount of acquired energy, is an example of such an action. The recovered energy can then be used for heating of radiators and tap water. This report aims to evaluate and compare three different systems using exhaust air heat pumps regarding COP, degree of coverage and cost savings. This study was delimited to only account for apartment buildings.The theory chapter describes the different conditions and factors that affect a building?s energy balance.
Datormodellering av en värmelagrande betongväggs inverkan på det termiska klimatet i ett växthus
This report describes the building of a computer model that makes it possible to simulate the thermal climate in a greenhouse. The computer model is built on the physical theory of heat exchange that occur in a greenhouse, such as radiation and convective heat exchange. The model also includes the heat storage that is active in a greenhouse.The computer model is used to simulate the thermal climate in a greenhouse under three periods, winter, spring and summer. It also investigates which effect a concrete wall has on the thermal climate in a greenhouse. The purpose of putting a concrete wall in the greenhouse model is to investigate the possibility to store heat during the day and then use this heat when the temperature drops during the night.The result from the simulations shows that a concrete wall levels the big difference in temperature that normally occurs under a day in a greenhouse.
En kombinerad Organisk Rankinecykel och värmepump integrerat med ett fjärrvärmesystem : Där värme- och elproduktion samt lönsamhet studeras och avfall är huvudbränslet
The demand for district heating is expected to decrease in the future, due to competition from heat pumps and energy efficiency measures in buildings. Development of existing district heating systems is therefore necessary for district heating companies to maintain market shares. This Master?s thesis describes and investigates the heat and electricity production and profitability of a combined Organic Rankine Cycle (ORC) and heat pump that is integrated with an existing district heating system. The studied district heating system is utilizing heat from waste incineration. In Sweden waste constitute 20 % of the fuel mix used in district heating systems, and this share is expected to increase in the future.