Sök:

Sökresultat:

444 Uppsatser om Geothermal heating - Sida 2 av 30

 Solenergi En del i ett långsiktigt, hållbart byggande

The sun is essential to life on earth and no matter where you are, there is a constant need ofenergy. Nearly 800 000 years ago man learned for the first time to use fire in a controlled way.Since then, fire has given us the opportunity to inhabit places despite a cold climate. In Swedenthe resident sector accounts for a major part of the total consumption of energy. In a time whenenvironmental issues and greenhouse effects are increasing, we also see a future of rising energyprices. With this perspective, we have in this bachelor thesis in the Building Environment at theRoyal Institute of Technology, KTH, in Stockholm decided to focus on the renewable energysource, solar energy.The energy from solar radiation is a free resource and does not have any negative effects uponthe environment.

Olika uppvärmningssystem : en fallstudie i mellansverige

The purpose with this project is to compare different fuels when investing in a central combustion station at a case study farm. I have chosen to write about biofuel from an economical perspective. This because the heating costs are steadily increasing. Also because the farm in this case study has several different heating systems, which are neither profitable nor easy to work with. I have made calculations regarding usage of splinter, wood and grain for the heating system.

Uppvärmning av mjölkgård med ved, flis eller havre :

The background for my thesis is the fact that with rising electricity and oil prices it becomes interesting to calculate on alternative heating systems. I have chosen to calculate upon my parents? farm, which today heats the dwelling house with wood. This is very time-consuming work, time which could be spent on other work. The main objective for this study is to compare three different heating systems to decide how they differ considering effort and cost. The result from the calculations was that grain-heating system demanded the least amount of work, but the total cost was a little higher compared to chips heating. Chips heating required half as much work as today?s wood heating and had a little lower total costs compared with the corn heating. Which system to choose largely depends on how the own work is valued.

Energieffektivisering - Laholms kyrkliga samfällighets kulturhistoriska byggnader

Energy efficiency is today more important than ever, mainly due to the high energy prices and the approaching climate changes. Heating of buildings is an essential area within energy efficiency. Many buildings are old and were built at a time when the energy prices were low and the term ?energy efficiency? was unheard of. By applying today?s broad range of energy saving actions on these old, and thereby often, heating ineffective buildings, this area has a large potential in reducing energy consumption and costs.Churches and chapels are generally old buildings with, in many cases, ineffective heating systems and therefore consume much more energy than needed.

Uppvärmd konstgräsplan : Beräkning av utnyttjningstid för en uppvärmd konstgräplan med alternativa rörplaceringar

For Skattkärr IF a turf field with warming has been projected to increase field?s utilization hours and to have a longer period for athletes to perform their activities outdoors. The technique chosen to heat the plan is a type of a Geothermal heating system without a heat pump. The brine, which is water with 30% ethanol, collects heat from the borehole and discharges it to a coil in the field. There is at position 11 boreholes but it is planned to increase the number to 31, which is the design for the facility.

Inventering av processvattenbalans : fastställande av fjärrvärmedistributionens läckage inom Vattenfall Värme Uppsala AB

Heat is distributed to the district heating customers through pipes with water as a heat carrier. The district heating system is complex. To decide what is leakages from the district heating net versus what is the water consumption of the plant, is difficult. Therefore, the purpose of this master thesis is to establish a model where the district heating net?s leakages but also the water consumption of the plant can be followed daily. The project is performed at Vattenfall´s district heating power plant in Uppsala. Information is gathered through discussions, drawings of the plant and guided tours of the plant.

Möjliga alternativ för att ersätta direktverkande el i flerbostadshus

I have in my thesis, examined the possibilities in terms of energy for a condominium association.To have an effective and good energy is becoming increasingly important with today's rising electric and oil prices. In my thesis I have used the condominium association Kärralyckan, which is situated in Falkenberg. The buildings at Kärralyckan are built in the mid-1970s, and are heated by electric radiators. The tap water is heated by an electric boiler.Based on that calculation I can show the various energyststem. The different solutions have been developed by contact manufacturers and installers through phone calls and e-mail.According to the results shows that Geothermal heating has been a great solution for Kärralyckan.

Kombinerat system för ventilation och rumsuppvärmning : Parameterundersökning i simuleringsmodell för takvärmesystem

A large amount of our time is spent indoors in an artificial climate. To make the experience pleasant there are requirements on the ventilation and the heating system. At the present time the most common form of heating is a radiator system complemented with a ventilation system. A ceiling heating system with combined heating and ventilation can replace the two separated systems. The benefit with a ceiling heating solution is that it saves space since the radiator system is no longer needed.

Morgondagens effektiva fjärrvärme : En beskrivande litteraturstudie

This report is made as a literature review, focusing on the work done to increase understanding of efficiency in the categories of substations and secondary heating systems, with respect to the deviation from the theoretically possible cooling off in the distribution network as well as the economic benefit that appear. The main purpose of a considerable part of the literature used in this report addresses the issue of identifying individual causes of reduced cooling in district heating systems. These literature resources have been compiled and summarized as part of the report.The technology of district heating is associated with benefits such as better use of the energy in a fuel. This is the case of cogeneration plants where serial generation of electricity and thermal energy increases efficiency compared with the parallel generation where heat is generated locally and electricity is generated centrally. Serial generation thus allows for lower primary energy demand.

Simulering av värmebehov för kombinerad kontors- och laboratoriebyggnad utan traditionellt värmesystem

In this Thesis the possibilities of designing a larger building that is very energy efficient in the sense that it would not need a conventional heating system are discussed. Solar radiation transmitted through the windows, internal heat from occupants, lamps and electric appliances inside the building and heat recovered from the ventilation system then have to be sufficient for the heating of the building. This study is of general interest since the property company, Akademiska Hus, plans to use this study as a first step in determining if this technique could be used in the future and thus be worth further investments. A building without a conventional heating system of the size investigated in this project has not yet been built.The energy needed for the heating of the building was simulated using VIP+.The conclusions from the study are that it is possible to build large buildings without any conventional heating system. This could be achieved in many different ways, for example by lowering the inside temperature or by using better windows and heat recovery system with higher efficiency.

Energieffektivisering i ett verkstadsföretag : En analys av energibesparande åtgärder samt uppvärmnings- och kylsystems driftkostnader och koldioxidutsläpp

The energy use in a workshop company has been examined in this work in order to find areas for energy efficiency improvement. The combined oil and electricity heating in the company were compared with other alternative heating systems including cooling of the premises in following combinations:Ground source heat pump for heating and coolingDistrict heating and absorption coolingDistrict heating and low temperate surface water coolingEnergy use, operation costs and carbon dioxide emissions were calculated for the current heating systems and the three alternatives including cooling. The ground source heat pump for heating and cooling decreases bought energy with 34 MWh annually compared to current heating only. The district heating and low temperate surface water cooling has the largest reduction of operation cost and carbon dioxide. The operation cost decreases with 42 kSEK and the carbon dioxide with 43 metric ton CO2 annually.

Sänkt returtemperatur : Potentiell besparing i fjärrvärmesystem

Optimizing energy systems is, in Sweden, as in many other countries, of growing interest. District heating systems are no exception. In 2012, 285 out of 290 municipals in Sweden had district heating in use and the majority of these systems have a higher return temperature than that which is possible with an error-free substation of day current technology. To, when possible, lower the return temperature is a way of increasing the effectiveness of the district heating system.This study means to investigate, through simulations and calculations, how big of a reduction in production cost a lower temperature in the city of Ystad?s district heating system would correspond to.

Analys och kvantifiering av energieffektivisering inom fjärrvärmesektorn

The Swedish Government has set a target to reduce energy consumption through energy efficiency within the construction and real estate sector. The purpose of the study is to examine how energy efficiency within this sector could affect the district heating volume in the future, on basis of Vattenfalls district heating system in Uppsala.An Excel model has been created to study how energy effficiency measures affects district heating demand in buildings by 2045, based on technical and economicalconditions. Furthermore, an interview study has been conducted to examine incentives for district heating customers to invest in energy efficiency measures.Result of the Excel model shows that the district heating volume of Vattenfall in 2045 is expected to 931 GWh, which corresponds to a volume decrease of 10,6 %. Based on the study?s theoretical framework only 15 %, 1 024 GWh, of the technical-economical potential is assumed to be implemented.

Energisäkerheten för fjärrvärmeanläggningars bränsletillförsel i Mälardalsområdet

There are several energy systems in the Swedish society and to ensure the comfort and health of the citizens it is of importance that the different energy systems are functioning properly. District heating is one of these energy systems and many household depend only on district heating to warm up their homes. District heating is dependent on several processes where every step needs to function in order to deliver the produced heat to the end consumer. Previous studies have investigated the distribution of district heating and how to make customers choose district heating as their heating method. The supply of fuel to the district heating plant has not been studied as much, even though it is an important part of the whole system. This thesis is a part of the project NORD-STAR (Nordic Strategic Adaption Research), which has focused on climate adaption in the Nordic countries.

Lantbruket som energiproducent : tekniska, ekonomiska och miljömässiga förutsättningar för fjärrvärmeproduktion med lokalt skogsbränsle

A third party access to district heating networks has been proposed in Sweden, to increase the competition on the district heating market. Such third party access could create opportunities for the agricultural sector as an energy producer. This study describes the technical, economical and environmental prerequisites for a farmer cluster to build and run a heating plant, fueled with local wood fuel. The heating plant in the described scenario is 8 MW and will supply a village of 1000 houses, and is fueled with wood chips exclusively. Supplying a heating plant with fuel puts high demands on the logistics, since there need to be a continuous flow of fuel. In the scenario, wood residues from felling and thinning is stored in stacks in the forest, and a few times a year chipped and transported to a storage area at the heating plant. In the study, an estimation of the profitability has been made by estimating the cost of the investment, personnel, operating and maintenance costs and costs for the fuel and ash handling.