Energikartläggning och driftoptimering genom behovsstyrning i befintlig fastighet
Energy supply in Sweden year 2011 amounted to 577 TWh. The final energy consumption for industrial, residential and service was 379 TWh. Sweden has energy policy goals to reduce energy use in buildings. One of these goals is to reduce the energy use by 20 % in 2020 compared to the year 1995. An important step to achieve this goal is to target energy efficiency measures in existing buildings.
Mätning av träddelar och flis på Dåvamyran, Umeå energi :
The moisture content in 10 deliveries of tree parts and 10 deliveries of wood residues were measured with different methods to analyze the quality of procedure used at Dåvamyran today. At the same time a survey was made on the measure procedures used at heating plants in Sweden
The majority of the heating plants in Sweden use weight and moisture content as base for payment but at some plants only volume. The moisture content is usually estimated by drying wood chips in an oven but few plants a visual estimation is used. At few plants moisture content is estimated spectroscopicily. The techniques using near infra read light and other electromagnetic are still at a test stage.
The methods of measurement used today are quit unreliable for the individual deliveries and there is a risk for systematic mistakes.
Energieffektivisering genom förvärmning av flis till kokare med sekundärvärme
The Swedish pulp and paper industry meets higher demand for energy efficiencyi mprovements with increasing energy prices and changes in the Swedish renewable energy certificate system. One action of energy efficiency improvement is by using secondary heat, that otherwise would have been treated as waste heat, for use in a system with lower temperature demands. The aim of this Master´s thesis is to identify possible secondary heat sources in a typical Swedish pulp and paper mill and to investigate what economic benefits the secondary heat will provide when being used for pre heating of wood chips to a kraft digester.The Master´s thesis focuses on three secondary heat sources; dry warm air, warm water and moisture saturated warm air located inside the pulp or paper mill. Two types of kraft digesters are simulated within this study, a typical Scandinavian digester and a modern twin vessel steam phase digester.Due to quality aspects and low temperature level drying is the drying technology with dry warm air rejected. Using warm water in direct contact with wood chips increases the quantity of water to the evaporation plant and thus reduced pulp or paper production and is therefore also rejected.
Renovering av flerbostadshus - en studie om energieffektivisering och lönsamhet
In today?s society a large focus is put on energy systems and how our energy systems are built up. In order to make sure that we in the future still can enjoy the living standards that we are used to today, Sweden and EU have made a number of decisions on making our energy system more energy efficient and consequently reduce the usage of energy resources. By 2020 the European Union should have reduced its energy consumption by 20 % compared to 1990?s level, and by 2050, 50%.
Produktion av Pyrolysolja från kvistrejekt
Fast pyrolysis is a method for converting biomass into three energy rich products: char, gas and bio-oil, where the latter is most interesting. Pyrolysis is an endothermic process where biomass is heated in an anaerobic environment and, with the right operating conditions, up to 80 %wt bio-oil can be extracted. Key parameters for fast pyrolysis are: stable reactor temperature (~500°C), short residue time for gas in the reactor (<2 s) and a very high heating rate for the biomass. Today there are several different process solutions for fast pyrolysis, where fluidized beds and rotating cones are most developed. Bio-oil has compared to fossil oil: lower heating value, low pH and also polymerizes with time. Because of this upgrading is desirable for increasing competitiveness.
Livscykelanalys: Pelletspanna från kvänum energi
This study will identify the environmental impact in terms of carbon dioxide for a boiler house on behalf of Kvänum energi. The boiler central consists of a main building, which in turn contains multiple components such as boilers, pipes, etc, the boiler central uses pellets fuel. It also includes a silo and an ash container. The total weight of the boiler is about 63 tons. Each boiler has an output of 600 kW; the central includes three boilers with room for a fourth if necessary.
Enegiutredning Hotell Princess
This report will show the energy usage of Hotel Princess in Sandviken, Sweden. When the hotel changed owner an examination of the hotels heating, ventilation and sanitary systems were done. The report showed flaws in the ventilation system, and is why the new owner wanted a closer look at the energy use of the hotel. The original building was built in the 1930s and two major extensions have been built, one in the 1950s and the most recent in the 1980s. An assumption made is that the building parts were built to the restrictions during the time. Activities on the hotel include sleep over, conference, night club, massage and swimming in the hotels pool section.
Energihushållning och varsamhet för äldre byggnader : Chefsbostaden i Strömsholm, ett timmerhus från 1900-talets början
This report is the result of a degree project in building engineering, at an advanced level. The project evaluated a building from a technical and historical point of view, and focused on its energy consumption, particularly the energy used for heating. The building in question was a small apartment building in Strömsholm, Sweden. It was made in 1902, from vertical logs, a not so common form of the traditional log house. The goal of the project was to evaluate if the energy consumption could be reduced in accordance with building preservation regulations, that is without damaging any of the building?s cultural or historical values.The building was surveyed with the help of archive and literature studies, interviews and inspections.
Energieffektivisering av Åhlénshuset i Umeå : Utredning av åtgärder för ventilation, värme och kyla
Sweden is a country that has made some progress in developing energy efficient solutions. The problem in Sweden is that many houses and apartment buildings are old and have inefficient ventilation- and heating systems. This energy is lost when systems are inefficient, which then results in huge economic costs. Luckily, more and more people are becoming aware of this, which means that Sweden is on track to become even better within energy efficiency.Energy use for the housing- and service sector amounts to 166 TWh of total use at 616 TWh. Without distribution and conversion losses, these figures show that the housing- and service sector accounts for almost 40 % of the country's total energy consumption.
Kaffesump som substrat i biogasanläggningar eller som bränsle i fjärrvärmeverk : en studie av effekter på växthusgasutsläpp och kostnader
Each year, the coffee machines at Ericsson in Kista produce around 100 tons of ground coffee waste.The companies Coor Service Management, Löfbergs Lila and Selecta are all responsible for differentstages in the logistical chain in delivering coffee and, together with Ericsson, they want to increasetheir environmental benefit. The plan is to produce biogas through anaerobic digestion instead ofincinerating the coffee waste in a heating plant. The results are to be presented as different businesscases in which different biogas plants are compared with the reference case (heating plant),comparing costs and environmental impacts.There are two major environmental benefits from producing biogas; reduced carbon dioxideemissions from when fossile fule is replaced by carbon neutral biogas, and reduced emissions fromreturning digestate from the bio reactor to farmland instead of using industrial fertelizer.In order to determine the biogas potential in coffee waste, a couple of properties had to bedetermined in a laboratory. Properties such as the dry substance content, heating value, moisturecontent and ash content. The results show that 100 tons coffee waste could produce around 16 500Nm3 biogas which would contain 163 MWh.The biogas reactor and upgrade plant both need energy gas to function and uses around 14 MWh ofthe produced gas.
Leanuppgift för industriprogrammet
The government regulations for energy use in buildings will be tightened in the future. At the same time the interest in environmental classifications and certifications of buildings is increasing. This has meant a new situation for solar energy. The designs of solar heating systems are often based on experience and/or rules of thumb, rather than calculations and simulations. This thesis examines whether simulation tools, in this case Polysun, are useful in this work.
Simuleringsprogram som verktyg vid projektering av solvärme
The government regulations for energy use in buildings will be tightened in the future. At the same time the interest in environmental classifications and certifications of buildings is increasing. This has meant a new situation for solar energy. The designs of solar heating systems are often based on experience and/or rules of thumb, rather than calculations and simulations. This thesis examines whether simulation tools, in this case Polysun, are useful in this work.
Optimering av glödgningsparametrar för kromstål
At Sandvik Materials Technology, Argon gas is used as furnace atmosphere when heattreating hot rolled wire. Upon heating chromium steel wire, a rich oxidelayer forms on the wire surface. The abstract of this masters thesis is to enhance the understanding of the constitution of the oxidelayers and the influence of the furnace atmosphere. This will be achieved by performing a number of annealing experiments on laboratory level. Also, the aim is to understand the chemical reactions and physical mecanisms controlling the pickling process.
Temperaturstyrning av aluminiumextruderingsprocess
In this final thesis a rough description of aluminium extrusion is made, the importance of temperature of both the raw material and the extruded profile for a good profile quality. The difficulty in controlling these temperatures are discussed and attempts to increase the control are described. The attempts are basically made by controlling the furnace that is heating the raw material. This is done in a manner that the raw material reaches its final temperature shortly before it is extruded. An IR-camera at the press can be used for profile temperature measurements.
OneCore
The Swedish building and property management sector are responsible for about 30 % of the total energy use. In order to take environmental consideration, different environmental assessment tools and standards are used. Miljo?byggnad, Svanen, FEBY12 and PHI are some of these. There has been increased interest to certify buildings and therefore it is of interest to evaluate the assessment of the energy field to see if relevant energy aspects are assessed.