Sökresultat:
9100 Uppsatser om Geothermal heat pump system - Sida 2 av 607
Analys av energianvändningen i kvarteren Carolina och Jenny : en fallstudie
An energy study has been performed on two blocks in an area called Gävle Strand. The buildings are owned by a tenant-owner?s association called brf Carolina and were built by the company Skanska 2008. The builder as well as brf Carolina are pussled by the fact that electricity use is higher than expected while heating is less. Skanska is also very interested in finding out how much heat recovery from stale exhaust air through a geo-thermal heat pump is contributing to the general heating requirement and energy balance in four out of the ten buildings located on the properties.To find possible answers to the higher electricity use a literature survey on user behaviour was conducted.
Värmeöverföring i bergvärmesystem : En numerisk analys av den ringformade koaxiala borrhålsvärmeväxlaren
The borehole heat exchangers of today suffer from poor thermal and hydrodynamic performance. The purpose of this thesis is to improve the performance of ground source heat pump systems and thermal energy storages by increasing the energy efficiency of the borehole heat exchangers. For this reason, the annular coaxial borehole heat exchanger (CBHE) has been analyzed. This type of heat exchanger is interesting in terms of both thermal and hydrodynamic performance. A model has been set up in the program Comsol Multiphysics in order to investigate the heat transfer characteristics along the borehole.
Geotermisk fjärrvärme i Gunsta
Gunsta is situated about 10 km east of Uppsala. Today there are plans to establish 1000 new households in Gunsta before year 2030. The required energy for heating houses and water would be distributed via a district heating system, which also includes 200 existing residences. The annual required energy, according to this study, would be 16.2 GWh with a maximal peak effect of 6.9 MW.
To meet this need, the study suggests a system with heat pumps to upgrade the 31?C water from a 1.8 kilometre deep borehole.
Hydraulisk och termisk grundvattenmodellering av ett geoenergilager i Stockholmsåsen
Geothermal energy can be extracted from an aquifer, where the groundwater is used as heatexchange medium while heat and cold are stored in the surrounding material in the aquiferand to some extent in the groundwater. Application of aquifer storage for the use ofgeothermal energy is mainly used in large scale facilities and is limited to sites with suitableaquifers in the form of ridges, sandstone and limestone aquifers.Löwenströmska hospital in the municipality of Upplands Väsby, north of Stockholm, islocated nearby the northern part of the Stockholm esker. This means that it can be profitableand environmentally beneficial for the hospital to examine the possibilities of aquifer storagein the esker material next to its property.The purpose of this master thesis has been to investigate if geothermal energy storage with aseasonal storage of heat and cold can be applied within Löwenströmska hospital?s propertyarea using groundwater modeling. A hydraulic groundwater model was constructed inMODFLOW based on a simplified conceptual model of the groundwater system.
Vibrationsdämpning av värmepump
Thermia Värme AB is one of the market leading manufactures of heat pumps. In order tomaintain this position, the company wants to improve the vibration characteristics of theirproducts. The aim of this thesis is to develop product design changes that lead to a reductionof vibrations in the heat pump Thermia Diplomat 8.The main cause for vibrations in the system is flow pulsation and mechanical forces inducedby the scroll compressor. Vibration is transmitted through the compressor piping and receivedby the heat exchangers, from where it is further transmitted to the connection points for theradiator and heat source circuits.A number of design changes in order to improve the vibration characteristics have beenevaluated through calculations and practical experiments. The changes have included thecompressor and heat exchanger mountings, the compressor suction and discharge line pipingand also pulsation dampening.The results of the experiments show that the vibration levels in the connections for the heatingand brine circuits can be decreased strikingly through changes in suction and discharge linepiping.
Ögonbehandling av häst med lavage system och infusionspump Omvårdnadsaspekter : omvårdnadsaspekter
Objective ? To study the requirement of nursing care of the equine patient during eye treatment with a lavage system together with a constant rate infusion pump.
Procedures ? Three veterinary nurses at ATG: s Hästsjukhus in Skara were asked nine questions at individual interviews. Inclusion criteria for participation in the interview were that the nurse should have treated equines with and without the infusion pump to the lavage system, but also traditionally with eye drops.
Results ? The equine had a higher well-being since it experienced less stress during eye treatment with the infusion pump compared to treatment given by hand through the lavage system. The treatment would be more effective with constant rate infusion and save costs for the owner.
Beräkningsalgoritm för fouling i pelletervärmeväxlare inom plasttillverkning
Sweden?s energy consumption is divided into three major sectors. One of them is the industry sector. One third of Sweden?s energy consumption is converted in the industries.
Systemlösningar för plus- eller passivhus : En studie med syftet att lösa energibehovet för ett specifikt hus.
The purpose of the house which is the basis of this report is to be able present itself on the market as a relatively cheap and at the same time a climate friendly choice. The house is supposed to be able to be built anywhere in Sweden and the rest of Scandinavia in a short period of time. This puts demand on what kind of heating system the house can have, since not all places have the geographic advantage of being able to use geothermal or district heating. Therefore the heating system choices will only include those that are not limited by their geographic location. The house will be built in modules which only require the groundwork to be done before the house can be erected. In this report "System solutions for plus or passive-housing" a comprehensive literature search has been conducted as well as a number of calculations.
Utvärdering av ett värmepumpsystems prestanda till en HWC-tvättmaskin : Med fokus på fläktvarvtal och köldmedieflöde
This report was performed in order to evaluate a new technological measure and focuses generally on a heat pump system to a HWC-washing machine. The client is Asko Appliances AB, a company well known for its environmentally friendly products. The goal of this study was to improve the energy efficiency of a washing machine by combining a heat pump device to the heater of the wash water, in order to reduce the energy consumed for heating the water. Besides reducing the energy consumption in heating the water, the washing machine was required to meet low noise and short operating time specifications. For that purpose, nine trials in three test series have been carried out.
Vitvarueffektivisering med hjälp av värmelagring : Simuleringsstudie kring energiförsörjning av vitvaror med hjälp av värmepump & ackumulatortank
The constant need of energy is something that affects us all no matter our current situation. Whether we are driving our car to work, taking the elevator or using the oven to cook dinner we end up relying on energy. Our whole society is continuously striving to achieve a higher grade of efficiency and the process of supplying ourselves with energy is no exception. The importance of appliances in our everyday life cannot be exaggerated and thus the importance of their high efficiency.Efficiency is already a keyword in the appliance industry with labels, stars and numbers helping us choosing the most suitable option for the task ahead. No matter how efficient appliances often use pure electricity as their energy source.
Geotermi i Ungern : Undersökning av Ungerns energisituation inriktat på geotermi samt kapacitetsfaktorn för det största geotermiska värmeverket i Mellaneuropa.
Hungary?s share of renewable energy in 2010 was 7.9 %, and their renewable energy goal for 2020 is 14.65 %. Geothermal energy is one option that could help to achieve the goal, since Hungary has favorable bedrock, the temperature gradient is above average and thepermeability is high. Today Hungary is importing just over half of its primary energy supply. Because of political conflicts between nations Hungary wants to expand its own production of energy.
Lagring av kyla med horisontella markvärmeväxlare för kylning av koncepthus i Mellanöstern
Norconsult AB has developed a solarhousing concept, a house designed for the warm climate in the Middle East andwith large quantities of solar panels installed. The cooling system for the house was designed in an earlier report, the purpose of this thesis is to investigate the possibility of short and long term storage of thermal energy via an underground energy storage volume.Two different designs of the storage and three different filling materials have been integrated into a model to simulate different cases. The first design consisted of pipes installed in the ground, without insulation. The second design consisted of an insulated concrete box installed to prevent thermal energy from the surrounding soil to flow towards the lower temperature regions within the storage. The three different filling materials were dry saudi sand, water saturated saudi sand and the filling material used by the client for energy storage in Sweden.The results from the simulations show that neither of the designs, regardless of the filling material, managed to extract enough thermal energy from the house to the ground to uphold the demands of indoor climate.
Hållbara uppvärmningsalternativ för hotellstugorna på Grinda : En kvantitativ studie gällande hållbara uppvärmningsalternativ på en skärgårdsö
Skärgårdsstiftelsen, which is responsible for several of the archipelago islands in Stockholm, has chosen to explore the possibilities for more sustainable heating systems in buildings on the islands in collaboration with KTH. A reduction of energy use and improving the efficiency of existing heating systems are included as part of the environmental work. This report studies the island of Grinda, which is located outside the area of Vaxholm in Stockholm. The study area consists of a guesthouse consisting of a restaurant as well as conference facilities and four neighboring cottages used for overnighting. The cottages now run solely on direct electricity, both for heating and hot water.
Morgondagens effektiva fjärrvärme : En beskrivande litteraturstudie
This report is made as a literature review, focusing on the work done to increase understanding of efficiency in the categories of substations and secondary heating systems, with respect to the deviation from the theoretically possible cooling off in the distribution network as well as the economic benefit that appear. The main purpose of a considerable part of the literature used in this report addresses the issue of identifying individual causes of reduced cooling in district heating systems. These literature resources have been compiled and summarized as part of the report.The technology of district heating is associated with benefits such as better use of the energy in a fuel. This is the case of cogeneration plants where serial generation of electricity and thermal energy increases efficiency compared with the parallel generation where heat is generated locally and electricity is generated centrally. Serial generation thus allows for lower primary energy demand.
Värmepumpars inverkan på elkvaliten
Modern technology and fast development of heat pumps, the hunt for savings in energy consumption and the strive for environmentally friendly energy sources, convenience, and financial profit, have made heat pumps a reasonable alternative for the heating of houses.When the heat pump starts it will consume a considerable amount of current, which may result in a short-lived voltage-drop if the power grid is weak compared to the start-up current.The company Fortum Distribution which owns and administrates electrical network is interested in an investigation that deals with heat pumps affect on the quality of electricity.The purpose of this investigation is to study fast electrical fluctuations (flicker) as a result of start-up currents for single as well as multiple heat pumps on the same electrical station and from this evaluate whether there will be any problems installing heat pumps..