Sök:

Sökresultat:

712 Uppsatser om Exhaust air heat pump - Sida 4 av 48

Förstudie för automatisering av manuell lödning

This degree project has been carried out in cooperation with Enertech AB in Ljungby and is pilot study to automating all current manual soldering. The soldering process accounts for a large part of the processing cost in the production of a heat pump. The process is also a quality risk and has a major impact on the lifetime of the final product.The Main task of this project has been to evaluate automation of the soldering process, to develop automation solutions and a principle layout, to draw the design changes required for the automation and to calculate the supposed solution.This pilot study has resulted in a suggested automation solution using laser as a heat source for soldering. Calculations of the solution show that a automating a laser soldering cell is very profitable..

Energibalansen för ett nytt flerbostadshus i Mellansverige : Beräkningar intervjuer och analys av energikraven i Boverkets Byggregler

Abstract   This degree project comprises 30 credits, i.e. 20 weeks of work. The work mainly deals with the energy balance for a multi-family house in Västerås and the requirements for energy conservation in the Swedish building code, BBR. Calculations of the energy balance are supplemented by a number of interviews. Energy conservation in general has become more important in recent years and the subject is in line with increased public awareness. This importance and attention is explained by environmental problems in general and global warming in particular, but also by rising energy prices.

Analys av off-design prestanda för ett absorptionskylsystem

This master thesis project at KTH is performed in the Mechanical and Aerospace Engineeringdepartment at University of Florida (UF). The thesis is a small part of a gas turbine researchproject where a vapour absorption refrigeration system (VARS) and a high pressure regenerativeturbine engine (HPRTE) are integrated together. The main objective is to build a computermodel of the VARS. The computer model is supposed to be used to analyse the off-designperformance of the VARS and should also be easy to integrate as a subroutine in a more complexsystem model. To model the VARS some knowledge of the absorbent/refrigerant mixture had tobe well known, in this case a mixture of ammonia and water.

Biogas på Wapnö : Analys av framtida energisystem

Considering that the price and demand for energy gradually has risen over the past decade and a wider discussion about the human impact on the environment has become increasingly more important and given a clearer role in modern society. This has contributed to increased incentives to reduce the use of fossil fuels and increase the use of renewable energy.The agriculture currently accounts for 20 % of Sweden's total greenhouse gas emissions. A way for an agricultural company like Wapnö AB to reduce their emissions could be to utilize existing renewable energy sources within their own premises.The report's aim is to create an energy audit of Wapnö?s existing energy system and how it changes with a future biogas plant in operation. The energy audit is used to illustrate how the company?s climate footprint could change.

Potentialen av värmebesparing i ett avlopps luftningsledning

This thesis aims at determining the heat losses in a property vent stack and its roof valve. Upon request of a company, the vent stack is analysed for possible heat recovering solutions to be implemented, while relining of the drain system is executed and with a suitable payback time for the economic investments. The heat loss calculations are based on data for properties that are located in the Stockholm region, but also easy to change depending on the situation. The calculations are done on pipes made out of cast iron, which still is the most common type of drain pipe in Sweden, and these are the pipes that relining is usually made on. The calculations that needed to take several variables into account have been done in MatlabR2014a and the thermos dynamical properties that were used in those calculations have been extracted from EES.Three different types of heat losses in the vent stack have been taken into consideration in this thesis.

Två presentationstekniker för grafer : deras styrkor respektive svagheter inom en bioinformatisk kontext

This degree project has been carried out in cooperation with Enertech AB in Ljungby and is pilot study to automating all current manual soldering. The soldering process accounts for a large part of the processing cost in the production of a heat pump. The process is also a quality risk and has a major impact on the lifetime of the final product.The Main task of this project has been to evaluate automation of the soldering process, to develop automation solutions and a principle layout, to draw the design changes required for the automation and to calculate the supposed solution.This pilot study has resulted in a suggested automation solution using laser as a heat source for soldering. Calculations of the solution show that a automating a laser soldering cell is very profitable..

Ombyggnation till passivhus

Energy issues are constantly increasing attention in today's society. People's impact on Earth isentered in more contexts. Many discussions are about how the entire social structure needs to bestreamlined in order to achieve sustainability. The residential and service sector accounts for 39 % oftoday's total energy consumption in Sweden and the increasing electricity prices have made buyersmore interested in energy issues.There are many buildings in need of refurbishment today, including all the apartments that werebuilt in the 1970s to reduce the housing shortage at the time. 650 000 apartments of one millionapartments were built during the so-called the one million program and is currently in need ofrefurbishment.

Design av en ejektorspädare samt ett system för partikelmassmätning av dieselavgaser

This master thesis was a subtask of a project called EMIR-1. The goal with the thesis was tobuild a system for particulate mass measurements in one of the engine test cells at KTH. Theparticulate mass measurements are planned to be measured with a TEOM.The exhaust gases must first be diluted with air before the sample is sent to the TEOM.Therefore an ejector diluter for this matter also was designed and evaluated in the thesis.Emissions measurements have been done both with and without dilution to determine thedilution ratio. Tests have been done for different speeds and loads.Problems with stability of the dilution ratio have been an issue throughout the process andpressure pulsations in the exhaust pipe are believed to be the cause. More tests have to be done tomake sure that this is the problem.One idea is to make the inner diameter of the diluter nozzle smaller and see if it changes thedilution ratio stability.

Modellering och simulering av det evaporativa bränslesystemet i en personbil

This thesis work has been performed at the department of diagnosis and dependability at Volvo Car Company, Torslanda. The background of this project is based on interest in ascertaining how different factors possibly can affect a diagnosis method, which has been developed to find leaks in the fuel tank and evaporation system. According to the OBD II requirements leaks with an orifice diameter larger or equal to 0,5 mm, must be detected. The idea of the diagnosis method is to create an over pressure in the system with an air-pump. The current through the pump is measured and correlates to the power consumed by the pump.

Enegiutredning Hotell Princess

This report will show the energy usage of Hotel Princess in Sandviken, Sweden. When the hotel changed owner an examination of the hotels heating, ventilation and sanitary systems were done. The report showed flaws in the ventilation system, and is why the new owner wanted a closer look at the energy use of the hotel. The original building was built in the 1930s and two major extensions have been built, one in the 1950s and the most recent in the 1980s. An assumption made is that the building parts were built to the restrictions during the time. Activities on the hotel include sleep over, conference, night club, massage and swimming in the hotels pool section.

Restvärmeåteranvändning från absorptionsvärmepumpar : en kartläggning av möjligheter och begränsningar vid Vattenfall Värme Uppsala Block 5

Vattenfall district Heating power plant in Uppsala produces district cooling with absorption heat pumps which leads to a large amount of waste heat that has to be cooled with evaporative cooling towers. The Environmental Court has ordered Vattenfall to survey the possibilities to recover the heat, which is the focus of this thesis.The study begins with an overview of the system, and conditions and limitations for waste heat recovery is examined. In the next step alternatives to recycle the heat is evaluated, either by direct recovering or by upgrading.First, the technical possibility of each alternative is discussed, and then the operation time and the amount of recovered heat is calculated. Those alternatives which are possible are brought further to an economic analysis.The cost of investment for each alternative constitutes the basis for a present value analysis. The results are put together in a table where the total amount of recovered heat is compared with the present value for the different alternatives.

Lönsam energieffektivisering : Ett samarbete mellan ÅF och kund

This thesis project has focused on studying ÅF?s business concept Energy Collaboration, which is their way of selling energy efficiency services. Thereforeongoing projects have been analyzed. The purpose was to determine achieved energy efficiency, costs and profitability for the studied projects. It was concluded that the Energy Collaboration is a good way of selling energy efficiency services, since the customer takes no risk and energy savings of about 15-25 % can be achieved with simple measures.

Val av energisystem för en hållbar stadsdel : En fallstudie av Östra Sala backe

Uppsala County has ambitious environmental aims for the planned residential area inÖstra Sala backe. In this thesis different energy sources have been evaluated todetermine which system that would be most favorable given currently availableinformation about the project. Planned energy usage has been divided into tap waterheating, space heating and power. Three base case scenarios were made with districtheating, small scale bio fuel and heat pump. Solar power and solar heating were thensimulated and the production from the two could individually be deducted from theenergy need in the base cases, constituting 9 different scenarios.

Att ta fram underlag för val av luftbehandlingssystem med återvinningssystem i Förvaltarens fastigheter

Sverige och EU har man som mål att halvera energianvändningen fram till 2050 och det arbetet måste starta nu. Det är 15 miljoner kvm byggyta som måste halvera sin energianvändning varje år och i 40 år framåt. Redan idag är 70 % av alla hus till 2050 byggda, vilket innebär att även om vi skulle bygga passivhus fram tills dess skulle det inte räcka för att nå målet. Det är alltså en stor utmaning att halvera energianvändningen till 2050. En jämförelsestudie har genomförts mellan två värmeåtervinningssystem.

Bergkyla och bergvärmeutredning för industrilokalen Rödbergsmyran 5 i Umeå, Västerbotten.

Grubbe Ventilation AB is a sheet metal and ventilation company who provides design, installation, service, and repair of ventilation. The company is expanding their business by building a new facility in Umeå, Västerbotten. The property is designed to be used for both office and industrial work.Grubbe Ventelation AB has not yet decided upon wish system which is to be established to provide the building with heating and cooling. The consulting firm Umeå Projekt Team has therefore been asked to investigate the possibilities to invest in geothermal- heating and cooling.If the investigation of a geothermal heating- and cooling system would provide favorable results it would be a very appropriate alternative that provides energy at low costs and are an environmentally friendly option as the energy comes from stored solar energy in the ground is provided by stored solar energy in the ground.The facility ´s heating and cooling consumptions are calculated in the program BV2 and the result indicate a heating demand of 185 000 kWh per year due to thermal transmittance, transmission losses, heating of warm water and a cooling requirement of 5500 kWh.Three different systems of geothermal heating and cooling were tested in the computer program Energy Earth Design. The results show no difference in the dimensioning of the drill hole if merely heating were to be used or both heating and cooling were to be established.

<- Föregående sida 4 Nästa sida ->