Sökresultat:
3664 Uppsatser om Energy-efficient building - Sida 19 av 245
Prefabricerade passivhusväggar
Background: The most energy efficient houses today are so called passive houses. These houses achieve high energy-efficiency partly by having well insulated walls. U-value describes the amount of heat transfered through a building element, the more insulation, the smaller U-value. A typical passive house wall have a U-value of 0.10 W/m2,°C. The passive houses are primarily made as small family houses and not as a block of apartments.
Fuktproblematik i platta på mark : En analys av uppkomsten till fuktproblem
When constructing a building, a number of aspects must be harmonized in order for it to fulfill requirements ? a building must fulfill requirements such a load-bearing, conservation of energy and a good indoor environment by means of, among other things, moisture proofing .Moisture problems in buildings can affect health negatively. As we are increasingly staying in indoors, demands on a good indoor environment are higher.This work starts with examining moisture problems in slab-on-ground solutions, and then links the various scenarios to moisture problems in a concrete slab of a real building. The building with moisture problems is located in Årby by in Borlänge and moisture damage was found in the slab at an apartment adjoining wall.By reviewing literature written within the field of moisture problem, making hand calculations and modeling in the program Comsol Multiphysics, judgments are made to find explanations as to why the rise of moisture occurred in the building in Årby by.Generally, the following guidelines may be used to reduce the risk of moisture problems in slab-on-ground constructions:Drying of construction moisture before laying the floor material.Using draining layer beneath the slab, to prevent capillary suction.Using insulation under the slab, partly for comfort and to establish the temperature difference between the ground and the concrete slab.Avoid direct contact between the wood and concrete, due to degradation and fouling smells that normally occurs.If necessary, use additional vapor barrier.In addition to the above, there are various methods for moisture-proof and moisture-monitoring by design or by the method ByggaF suited for the entire construction process various events..
Optimering av informationsinsamlingvid prototyptillverkning
This report discusses a method to detect divers in harbour environments usingpassive acoustic detection. The goal was to achieve as high detection as possiblewithout having too high false alarm rate. A short execution time was also desirable.By using the characteristic of an inhalation a band-pass filter was applied to the signalto improve the signal to noise ratio. After the filtering an energy estimation of thesignal was made. This energy estimation was later used in a frequency analysis, whichcould tell us if there were enough energy in the frequencies that correspond to adivers breathing frequency.
Viking center
My diploma thesis has focused on creating a proposal for a Viking center in Stockholm that meets the international interest. A building dedicated solely to the Viking heritage. My ambition has been to give the Viking center an architecture that can serve as scenography for its exhibitions and to give the visitors a feel for the Vikings that they have been craving. A boat-shaped building in tribute to the Vikings boat building skills with curved stems of equal height that gives a familiar silhouette to the city. A wood building constructed of curved beams and wood columns painted with tar..
Värmeåtervinning ur spillvatten i befintliga flerbostadshus
Drain water heat recovery is an uncommon measure in multi-unit residential buildings. There istechnology available for the purpose but the knowing and experience of the heat recovery systems islittle. The purpose of this thesis is to evaluate the future potential of drain water heat recovery inmulti-unit residential buildings.A major part of the multi-unit residential buildings in Sweden were built during modernismen andrekordåren (1940?1975). Many of the buildings have worn out drain and water supply systems andmany are in need of a general refurbishment.
Beräkningsalgoritm för fouling i pelletervärmeväxlare inom plasttillverkning
Sweden?s energy consumption is divided into three major sectors. One of them is the industry sector. One third of Sweden?s energy consumption is converted in the industries.
Primärenergianvändning av passivhus i Sverige : Med fokus på Kvarteret Trettondagen
The building sector accounted for around a fourth of the total energy usage in Sweden in year 2010 (Energimyndigheten, 2012). Therefore it has become very interesting to achieve a lower energy usage in residential buildings. One way to achieve that is to build so called passive houses. By being very well insulated and have low leakage through the walls, they can reduce the energy usage for heating with a substantial amount. The first passive house was built during the 90?s in Germany; and in Sweden the first passive house was built in Gothenburg 2001.
Solvärme för en skola i Lerum. Studier av olika systemalternativ.
Two elementary schools are now being built in Gråbo (in the municipality of Lerum),Röselidsskolan and Ljungviksskolan, which are both designed with solar thermalcollectors for the schools domestic water heating. During the summer while thelargest amount of solar heat can be generated, the activity hence the domestic wateruse in the schools are heavily reduced. Both schools are connected to the local districtheating system which makes it possible to use the solar collectors to deliver heat tothe district heating.The purpose of this thesis is to evaluate the two systems mentioned above and todetermine which system is more suitable to apply on a school. The building whichconditions were used for this evaluation is Röselidsskolan.A solar heating plant of each system type was dimensioned from the expected andknown conditions of the building. The purpose with the dimensioning was to makethe solar plants replace the ordinary energy source as much as possible.
En kostnadsanalys av energieffektiva flerbostadshus
In Sweden the real estate sector accounts for 33 % of energy consumption and just below 10 % of the emission of carbon dioxide. As a consequence of the external pressure from climate change it?s in everybody?s interest to reduce the energy consumption and thus reduce the emission of carbon dioxide. An additional incentive to reduce the energy consumption is the substantial increase of the energy price since the deregulation of the electricity market in 1996.In this study the techniques that exist to build multi-storey residential buildings with high energy performance will be investigated. Further the study intends to investigate the optimal energy performance from a real estate economic perspective.In order to investigate the optimal energy performance a model has been created with the parameters investment cost, rental revenues, operation and maintenance cost, discount rate and investment horizon.The result shows a relationship between a high investment cost and a high energy performance for newly constructed multi-storey residential buildings.
Sigma energy app
Sigma energy app is a mobile application for subscribers to various energy subscriptions. The subscribers can use this mobile application to access information regarding their consumption, invoices and active subscriptions. The mobile application that was built consists of a GUI and a web API as middleman between the application and the database. .
Avblås för torkning av kabel
This report is written on the assignment by Nexans IKO Sweden AB in Grimsås which is a cable manufacturing company. Nexans IKO Sweden AB was in need of help to examine possibilities for saving energy by saving compressed air, in first place by using the compressed air more efficient. The task was to determine the present situation, making the airwipe stations more efficient by reducing the consumption of the compressed air and in turn save money. Even the aspects of the working environment were discussed as the noise levels from the pneumatic systems and engines are usually high. A schedule over the airflow in the factory and the inventory over current airwipessituation was made.
Passive acoustic diver detection
This report discusses a method to detect divers in harbour environments usingpassive acoustic detection. The goal was to achieve as high detection as possiblewithout having too high false alarm rate. A short execution time was also desirable.By using the characteristic of an inhalation a band-pass filter was applied to the signalto improve the signal to noise ratio. After the filtering an energy estimation of thesignal was made. This energy estimation was later used in a frequency analysis, whichcould tell us if there were enough energy in the frequencies that correspond to adivers breathing frequency.
Vitvarueffektivisering med hjälp av värmelagring : Simuleringsstudie kring energiförsörjning av vitvaror med hjälp av värmepump & ackumulatortank
The constant need of energy is something that affects us all no matter our current situation. Whether we are driving our car to work, taking the elevator or using the oven to cook dinner we end up relying on energy. Our whole society is continuously striving to achieve a higher grade of efficiency and the process of supplying ourselves with energy is no exception. The importance of appliances in our everyday life cannot be exaggerated and thus the importance of their high efficiency.Efficiency is already a keyword in the appliance industry with labels, stars and numbers helping us choosing the most suitable option for the task ahead. No matter how efficient appliances often use pure electricity as their energy source.
Passivhusen på Oxtorget
Syftet med vårt examensarbete är att undersöka hur passivhus eller så kallade nollenergihus skiljer sig i funktion samt uppbyggnad från konventionella hus.I vår undersökning tar vi upp hur utformning, orientering, material samt ett väl fungerande klimatskal påverkar energiförbrukningen.Vi har tittat närmare på faktorer som sparar energi samt hur ett typiskt passivhus är uppbyggt. För att se hur teorin fungerar i praktiken har vi tittat närmare på befintliga passivhus, nämligen de på Oxtorget i Värnamo.Vi har kommit fram till att passivhus fungerar och vi anser det som väldigt viktigt att man fortsätter driva fram arbetet och informera om dess betydelse för miljön.Passivhus blir mer och mer uppmärksammat. De är något dyrare att bygga, men man tjänar in det i längden. Lönsamheten är dock inte det viktigaste utan känslan av att man gör något bra för miljön..
Continuospel pa? barockcello : en diskussion kring Quantz? ide?er och en underso?kning av mina egna musikaliska verktyg
This thesis investigates how energy is used in three public baths today and suggests measures that could reduce the energy demand. The results show that there is a great poteltial for energy savings i public baths, and that it would be interesting to examine some of the proposed measures further..