Sökresultat:
2244 Uppsatser om Energy measurements - Sida 17 av 150
Energihushållning och varsamhet för äldre byggnader : Chefsbostaden i Strömsholm, ett timmerhus från 1900-talets början
This report is the result of a degree project in building engineering, at an advanced level. The project evaluated a building from a technical and historical point of view, and focused on its energy consumption, particularly the energy used for heating. The building in question was a small apartment building in Strömsholm, Sweden. It was made in 1902, from vertical logs, a not so common form of the traditional log house. The goal of the project was to evaluate if the energy consumption could be reduced in accordance with building preservation regulations, that is without damaging any of the building?s cultural or historical values.The building was surveyed with the help of archive and literature studies, interviews and inspections.
Solenergi och värmelagring i kvarteret Lagern
Humanity stands before a huge challenge to lower its emissions of carbon dioxide and its use of energy at the same time as the global population is rising and the developing countries are being industrialized. A lot of newly built buildings are due to this challenge, designed to be more energy efficient but also use renewable energy resources instead of pollutant fossil fuels .Solar energy is one of the purest forms of energy that exists in abundant amounts, which is why it is most likely that it could come to play a major part in the future energy market. The main purpose of this report is to investigate the possibility to implement a sustainable energy system with solar thermal heat and heat storage as main sources of energy in the neighborhood ?kvarteret Lagern?, which is the area where the old football stadium ?Rasunda Stadion? was located. New developments within different heat storage techniques have opened up new approaches to enable buildings an all year round heat supply from solar energy. This report will focus on heat storage in boreholes. At the present here is only a preliminary plan of how the neighborhood is supposed to be designed.
Bestämning av kroppssammansättning hos överviktiga och obesa ammande kvinnor. Validering av bioelektrisk impedans mot röntgenabsorption.
Introduction: Pregnancy, obesity, aging and certain diseases are examples of conditions thataffect the body, its constitution and composition. Simpler methods to estimate bodycomposition are needed to complement more advanced traditional methods to better identifythe health status without sacrificing accuracy and precision.Objective: To validate the results of body composition from bioelectrical impedancespectroscopy (BIS) against results from the study reference method, dual energy X-rayabsorption (DXA), in overweight and obese lactating women after childbirth.Method: The design of the LEVA-study (Lifestyle for Effective Weight loss during lactation)consisted both intervention and longitudinal follow-up, which gave the opportunity tovalidate the absolute values (accuracy) and the ability to detect changes (precision). Themean difference between methods was tested statistically by paired t-test. Bland-Altman plotsused to examine the degree of agreement between BIS and DXA, but also distribution andany systematic differences. Association between methods was measured by using Pearson´scorrelation coefficient.Results: Between BIS and DXA, absolute measurements of the variables fat-free mass (FFM)and fat mass (FM) showed a statistically significant difference (p < 0.001).
Energieffektivisering och solenergi i en universitetsbyggnad : Undervisningshuset och Biblioteket i Uppsala
Akademiska hus is a real estate company that specializes in providing Swedish universities with housing facilities for educational and research purposes. The company strives to reduce its use of energy by 40% between the years 2000 and 2025. The aim of this thesis is to determine which measures can be taken to reduce the need of purchased energy in a building that is used by theSwedishUniversityof Agricultural Sciences inUppsala.In order to determine the results of various changes to the building envelope and ventilation system, the building was modelled in the computer simulation program VIP-Energy. Other proposed changes to make the use of energy more efficient concerned water use and lighting. The need of purchased energy can also be reduced by producing electricity or heat on site, using solar energy.Results show that economically viable measures include upgrading windows and faucets, adjusting control systems for ventilation and lighting, and installing roof mounted solar panels for power production.
Personalens följsamhet till riktlinjer avseende glukoskontroll postoperativt efter Coronary Artery Bypass Graft (CABG)
The aim of the study was auditing medical records examine postoperative blood glucose levels after undergoing CABG surgery. Furthermore the aim was to determine if the ward staff abides the local guidelines frame of reference concerning each ward, regarding blood glucose measurements and blood glucose levels. The study included 70 patients undergoing CABG surgery at the cardiothoracic surgery, Uppsala University Hospital. The study was conducted by retrospective medical record auditing. Studied factors were postoperative blood glucose levels, number of registered blood glucose measurements, a current diagnosis of DM and preoperative HbA1c.
Design av en ejektorspädare samt ett system för partikelmassmätning av dieselavgaser
This master thesis was a subtask of a project called EMIR-1. The goal with the thesis was tobuild a system for particulate mass measurements in one of the engine test cells at KTH. Theparticulate mass measurements are planned to be measured with a TEOM.The exhaust gases must first be diluted with air before the sample is sent to the TEOM.Therefore an ejector diluter for this matter also was designed and evaluated in the thesis.Emissions measurements have been done both with and without dilution to determine thedilution ratio. Tests have been done for different speeds and loads.Problems with stability of the dilution ratio have been an issue throughout the process andpressure pulsations in the exhaust pipe are believed to be the cause. More tests have to be done tomake sure that this is the problem.One idea is to make the inner diameter of the diluter nozzle smaller and see if it changes thedilution ratio stability.
Finansiärer ur ett hållbarhetsperspektiv : En aktörsstudie av Europeiska Investeringsbanken, Nordiska Investeringsbanken och Svensk Exportkredit
Today a major part of the energy produced steams from fossil fuels, finite resources, and a change towards an energy sector based on renewable energy is necessary. Sweden is one of the leading countries with regards to investments in renewable energy but most other countries have a long way to go. This makes it interesting in developing renewable energy projects in new markets in countries like Poland where still a lot of fossil fuel is used. Large infrastructure development projects are very costly and therefore external investors needs to be involved. The investors play an important role in changing the usage of fossil fuels towards renewable energy sources.
Solel till Akademiska sjukhuset : möjlig genererad effekt och solcellers estetiska konsekvenser
Today many buildings and it´s nearby surroundings are designed to achieve some kind of environmental goal.The issue concerning energy consumption is currently at focus and it is relevant that we start increase the share of renewable energy. Solar energy is an infinite resource and should therefore be considered when selecting an energy supplier. Uppsala University hospital is facing major restructuring when parts of the existing buildings will be refurbished and a large new building will be constructed. White Architects have developed a study concerning the new building and for some of the existing buildings on the hospital campus. Uppsala County requires tough energy measures and wants the new building to be classified as an eco-building in Whites following work. The classifications will involve high energy source requirements. This work has been conducted to see if solar power can be envisaged as a supplementary energy source for the University hospital and also to investigate the aesthetic impact of solar cells on the new building.
Prestationsmätning ur ett kostnadsledarstrategiskt perspektiv : En fallstudie på Gekås Ullared AB
Bachelor thesis, Business Administration and Economics Programme, School of Business and Economics at Linnaeus University in Va?xjo?.Spring of 2015 Title: Performance measurement from a cost leadership perspective - A case study on Gekås.Authors: Adrienn Csiszer, Hannah Lundberg & Helena WennerströmTutor: Eva GustavssonExaminer: Karin Jonnergård Keywords: Performance measurement, Performance measurement systems, Generic strategy, Cost leadership strategy, Financial and non-financial measurements. Purpose: The purpose of this study is to examine how a company with a clear cost leadership strategy chooses to work with performance measurements, with a view to comparing a practical example to theorethical approaches. Methodology: The method chosen for this paper is a case study on Gekås AB. The presented data were collected through interviews conducted with four employees on Gekås. Conclusion: The study concludes that for a business with cost leadership strategy the financial measurements are more important than non-financial meausurements. For Gekås it is important to keep the performance measurement simple and understandable for the employees. They only use three measurements (sales, hours and sales per hour) in planning and in evaluation.
Indirekt blodtrycksmätning på katt : påverkan av metod, miljö och ålder
The purpose of the present study was to study if the systemic blood pressure in cats
significant increases due to stress associated with a visit to a veterinarian clinic. We
also wanted to investigate the clinical utility of two different methods for indirect
blood pressure measurements in cats by assessing how easy they were to use and how
reliable measurements they provided. The methods that were used were oscillometric
(Memo Diagnostic) and ultrasound-doppler technique (Minidop). The blood pressure
was measured in both clinical environment and home environment. Fifty cats were
used in the study, from which measurements were impossible to obtain in one cat.
Självkörande fordon : En analys av energianvändning och kapacitet
Self-driving cars are soon to become a reality to the commercial market. A self-driving car does not have a human operator, which enables some interesting characteristics. The main benefits are considered to be:The number of accidents and traffic jams should be reduced.Enhanced comfort.Energy usage could be decreased while capacity could be increased.This study concerns the causes for improved energy efficiency. The reason for improved energy efficiency is mainly because of the variation in terms of acceleration, braking and distance holding are reduced. The vehicles are more intelligent and can work together as a unity.
Engergieffektivt Bostadsområde : Förstudie Till Aktivhusområde i Halmstad
In the thesis we have shown that it is possible with current technology, to buildneighborhoods that are largely self-sufficient. We have obtained some information aboutongoing work in the field of energy efficient buildings and active house which we have usedto develop a model. The feasibility study for Ranagård we have e.g been forced tofollow laws on groundwater covered, resulting in the construction of basements for singlefamilyhome is not possible. The model that we have built up overtime has been the central part of the work. The model illustrates very well what an activehouse neighborhood means and potential of such an area.
Modellering av hydrauliskt aktuatorsystem
This report treats a Master Thesis performed at Scania CV AB. The task was to create a computer model of a hydraulic actuator system in the software AVL Hydsim. The system consists of two spring-loaded masses with surrounding hydraulic components. The purpose of the model is to study phenomenon and problems in the system, as well as to be a support in the development of the system. It is not supposed to be used to study absolute values in its current form.
Energieffektivisering i ett verkstadsföretag : En analys av energibesparande åtgärder samt uppvärmnings- och kylsystems driftkostnader och koldioxidutsläpp
The energy use in a workshop company has been examined in this work in order to find areas for energy efficiency improvement. The combined oil and electricity heating in the company were compared with other alternative heating systems including cooling of the premises in following combinations:Ground source heat pump for heating and coolingDistrict heating and absorption coolingDistrict heating and low temperate surface water coolingEnergy use, operation costs and carbon dioxide emissions were calculated for the current heating systems and the three alternatives including cooling. The ground source heat pump for heating and cooling decreases bought energy with 34 MWh annually compared to current heating only. The district heating and low temperate surface water cooling has the largest reduction of operation cost and carbon dioxide. The operation cost decreases with 42 kSEK and the carbon dioxide with 43 metric ton CO2 annually.
Energikloka hus i Järinge - energiteknisk uppföljning
Energy-wise houses in Järinge - technical follow-up The company JM built energy-efficient houses in Tensta in Stockholm. They have built a total of 16 houses divided into two parts of A-houses and B-houses. The buildings are an attempt by JM to minimize energy-use of the buildings without affecting the comfort and living standards. The project aims to examine the data for the 16 houses on the basis of data and produce a report showing how the buildings worked through a technical perspective. JM approximates that the purchased energy will not be higher than 95 kWh/m2 per year.