Sök:

Sökresultat:

1648 Uppsatser om Energy declarations - Sida 19 av 110

Solcellsdrivning av distribuerade inbyggda system

The high level of energy consumption that the industrialised countries have reached and thepollution that this brings has long been a cause for analysis and debate, development and usageof so called renewable energy sources is therefore more important than ever. The energy in theelectromagnetic radiation from the sun is an interesting alternative. One way of harvesting thisenergy is by using solar cells, devices that generate DC current when exposed to electromagneticradiation.The goal of this master?s thesis was to design a solar powered power supply to Syntronic AB?sMidrange platform. The envisioned application is a stand-alone distributed embedded system,for example a node-based temperature monitoring system.

Energieffektivisering av befintliga sjukhusbyggnader - Analys med avseende på kostnad och energibesparing

The climate changes that are occuring in the world have resulted in that the EU callingfor a 20 % reduction in energy consumption to the year 2020, to reach that goal theEU want the public sector to go forth as a good example. Västfastigheter owns andmanage the hospital buildings in the Västra Götaland region. To be able to reducetheir energy usage Västfastigheter has hired several consulting firms to chart out theenergy consumption on each hospital building. The biggest energy savings potentialhave been calculated and what the cost will be to perform each action. The energyaudit have been completed and stand as the decision basis for Västfastigheter?s choiceon which action packages that should be implemented.

Metod för beslutsstöd vid formulering och uppföljning av en kommuns klimatmål : fallstudie Uppsala kommun

The purpose of this study is to create a method that can be used to produce decisionsupport data for the climate goals of a municipality. The method should be able to demonstrate the potential for reducing energy use and greenhouse gas emissions for measures aimed at the stationary energy system in the municipality. It will be used to make longterm projections of energy use and greenhouse gas emissions in order to be able to demonstrate the ability to reach climate goals. The aim was also to test the method's applicability by using the municipality of Uppsala and the Uppsala climate protocol project in a case study. Uppsala climate protocol is a project consisting of participants from business, government and organizations that voluntarily want to commit to reducing their carbon footprint by reducing their energy use and thus work to achieve the municipality's overall climate goal. Public reporting of energy use and climate impact has been studied in order to examine the nature of indicators and accounting figures that are commonly used in the field and how long-term forecasts are formulated. In connection to this, the type and sources for the kind of data needed was also examined.

Värmeåtervinning ur spillvatten i befintliga flerbostadshus

Drain water heat recovery is an uncommon measure in multi-unit residential buildings. There istechnology available for the purpose but the knowing and experience of the heat recovery systems islittle. The purpose of this thesis is to evaluate the future potential of drain water heat recovery inmulti-unit residential buildings.A major part of the multi-unit residential buildings in Sweden were built during modernismen andrekordåren (1940?1975). Many of the buildings have worn out drain and water supply systems andmany are in need of a general refurbishment.

Utvärdering av magnetiska alternativ till optisk scanning

This thesis includes an energy survey of the Herrgården pre-school, which has a modern heating- and ventilation system, and a comparison with Östers pre-school which has an older system. An energy survey of Östers pre-school has already been done by a group of three students and all the calculations and values have been collected from that survey. As of today, both pre-schools are heated thru district heating. It will be much easier to make smart and feasible energy-saving-measures by first conducting the energy survey.Herrgården pre-school in Gävle houses 81 children, therteen teachers, one cleaner and one cook. It was finished in the middle of 2009 and the staff has been very pleased with the in-door climate.

Utvärdering av befintliga passivhus : En byggnadsfysikalisk bedömning och mätningar om temperatur, och fukt analys på ytterväggarna

Energy price are on the way up to a high level that will not diminish in the future make us to focus more on the sustainable development for a better solution of residential houses. Passive house or low energy housing are one of the solution to make residential more environment friendly, in same time it´s a financial security using less energy, and saving money. The last 10 years in Germany and all around Europe the concept of passive house been developed, and people aim to know more about these concept that leading the market more attractive for passive houses. A passive house is a well designed building highly insulated and air tight with mechanical ventilated system for the whole building envelope that minimizes the use of energy for heating [1].The housing company Mimer has chosen to invest in low energy consumption in every new housing project.  These future plan projects are decided to use less than 75 kwh per square meter annually in purchased energy [2].This thesis is about new constructed passive houses, and focuses on the evaluations of the temperature, and moisture condition for attic, external walls and joist.

Klimatskärmens funktion : En jämförande analys av projekterade nybyggnationer i Östra Salabacke, ur ett energi- samt fuktperspektiv

The design of the building envelope affects the energy consumption of a building. As the energy requirements for new buildings are becoming more demanding, the performance of the building envelope must be improved. Energy efficiency and durability are important attributes to consider.This report includes investigations of the building envelope, moisture and passive solar energy. It is based on the analysis of two different buildings with different designs. These buildings stand as reference for two of the companies who are working on a new, climate smart, residential area in Uppsala, Sweden.Studies and analyses on energy consumption and moisture transportation were made.

Passivhus - En undersökning om varför det inte byggs fler passivhus i Sverige

This thesis tries to clarify why more houses such as passive houses is not built and at the same time the differences is described with the conventional construction as a starting point. Sweden has set environmental objectives to reduce energy consumption in buildings by 50 percent by the year 2050 compared to 1995. The passivehouse concept could have a significant role, particularly in the reconstruction of buildings with high energy consumption. For sustainable building the passivehouse technology is an economically viable concept while benefiting the environment. Initially an introduction is given of the background to the problem, purpose and objective of the thesis.

Implementation av ett digitalt vågfilter på en SIC-struktur

When implementing syncronous filters with global clock nets, a substantial amount of energy is consumed in the clock net. Hence, it is interesting to reduce the size of the clock net, which in turn will reduce the total energy consumption. One way to acheive this, is to create a SIC (Structured Interfacing of Computational elements) since such a structure can be created without a global clock net. Our results show that a fifth order wavedigital filter with a sample rate of at least 10M samples/sec may be achieved.

Framtidens energieffektiva flerbostadshus

The housing sector of today represents for almost 40% of the energy consumption, an energy consumption of which the major part consists of non-renewable energy sources. This is not sustainable and utilization of new energy-efficient technologies in buildings can be a step in the right direction, towards a sustainable energy society.This report has been made on behalf of and in cooperation with Älvstranden Utveckling AB in Gothenburg to examine how future energy-efficient technologies can affect the energy demand in energy-efficient multi-dwelling buildings.The report is based on Älvstrandens passive house, Hamnhuset, a house whose energy consumption is far below the BBR's requirements. The report looks at the opportunities for improvement within windows, insulation, solar energy technologies, as well as white goods. Computer simulations are then made to apply the selected technologies into a reference building. Technologies are selected from an energy efficient perspective and no account has been taken of other aspects such as the economy.

Enstudie om lågtempererat värmesystem i vägg : -Fokus på inomhusklimatet och energianvändning

Today the human being see energy as a matter of course but the resources that is used for extract energy is today not enough for the world demand. Of all the energy that is used in Sweden today approximately 40 % goes to the building stock. This number will most likely increase if not necessary actions will be made on the already existing building stock since new houses constantly are built which will be added up on the already existing energy supply. This takes cause of action on the already existing building stocks, to fulfill the demands of the future use of energy that has been set by the authority. At the same time the thermal conditions cannot be influenced by the necessary changes that must be made.

Uppgradering av automatisk teststation

The climate changes that are occuring in the world have resulted in that the EU callingfor a 20 % reduction in energy consumption to the year 2020, to reach that goal theEU want the public sector to go forth as a good example. Västfastigheter owns andmanage the hospital buildings in the Västra Götaland region. To be able to reducetheir energy usage Västfastigheter has hired several consulting firms to chart out theenergy consumption on each hospital building. The biggest energy savings potentialhave been calculated and what the cost will be to perform each action. The energyaudit have been completed and stand as the decision basis for Västfastigheter?s choiceon which action packages that should be implemented.

Prefabricerade Passivhus

European Union has made a new decision that all new built houses by 2020 shallbe near-zero energy houses. Boverket?s definition of near-zero energy housesintends buildings with good energy performance in which a proportion of theamount of energy that must be added to the building is made of renewable energy.Passive House is a set of requirements from FEBY designed to build energyefficient buildings. This is achieved by reducing loss of heat through the buildingenvelope and to take advantage of the passive heat from solar radiation,installation and heat sources like people living in the house.This project has been made with help of Anebyhus and one of their model houseshave been examined from the report?s issues, including Anebyhus?s energyperformance, requirements for the manufacturing and assembly, how theenvelope must be improved to fulfill the requirements for the Passive House andwhat energy calculation programs are available on the market.The report aims to provide solutions for energy efficient houses that are adaptedfor production of house building.Two visits to Anebyhus has been done to study their manufacture and assemblyof building elements.

Fejans vandrarhem ? En studie om isolering och uppvärmningsalternativ

During the last decennium climate issues have become more and more important. Many steps towards an adaption of efficient energy supply systems have been taken all around the world. These steps have been created to ensure the next generation?s energy demand. In EU and Sweden objectives have been set to ensure that the energy consumption decreases by 20% year 2020 and by 50% year 2050 compared with the energy consumption levels of year 1995.

Prestandaförändringen hos en bergvärmeanläggning efter fem års drifttid

The aim of this report was to do a case study at a geothermal heating system which has been in operation for about 5 years, and study if its performance has changed during this period of time. A literature study about the processes involved was also done in purpose of background knowledge.The tenant-owner?s association Duvan at Petterslundsgatan in Uppsala installed year 1999-2000 a geothermal heating system. The purpose of this installation was that they hoped it would lead to a smaller usage of district heating which would lead to a reduction of the heating expenses for their buildings. The geothermal heating system consists of 19 energy wells and 4 geothermal heat pumps, and it is one of the first systems of that size in the region of Uppsala.

<- Föregående sida 19 Nästa sida ->