Sökresultat:
2215 Uppsatser om Energy balance - Sida 11 av 148
HÅLLBART BYGGANDEMED HJÄLP AV BIM : Effektiva energianalyser och LCC
The society strives for sustainable development, in the construction industry it is expressed through sustainable building. Energy and LCC analyzes increases the ability to make conscious decisions in the process. A problem in the construction industry is that energy and LCC analysis is not used to the desired extent, as they are perceived as complicated and time consuming. The report aims to achieve a more sustainable building through increased use of energy and LCC analyzes.The goal is to show how BIM can be used to improve the efficiency of the energy and LCC analyzes.The study was conducted with a literature review and a case study to answer which information that is required in a BIM model to perform energy and LCC analyzes. The study also shows which software can be used in BIM based energy and LCC analyzes and how the analyzes can be carried out efficiently.The result shows that effective analyzes may be performed if the BIM-model contains the relevant information for making analyzes.
Upplevd trafiksäkerhet med mittbarriär
AbstractThis report intends through a case study to investigate if lightweight concrete isappropriate as main material in the outer wall of a seven storey residential building.A technical design is carried out in accordance with the definitions and requirementsfor passive houses, given by FEBY?s1 ?Demand specification for passive houses?.A literature review is also carried out for a comparison between regular bolt wall andlight weight concrete wall, with a focus on the safety of moisture.The lightweight concrete block used in the report is as a celblock produced by thecompany H+H Sweden AB.The methods used have resulted in compliance with requirements andrecommendations from authorities. Calculations of energy, noise and moisture riskassessment has been carried out.The work has resulted in the conclusion that the lightweight concrete itself is notable to isolate in the extent necessary to obtain chosen U-value of 0,1 W/m2 ° C,without getting to thick. Therefore additional insulation is needed. There are fewrelevant reference objects built with only light weight concrete.
Energikartläggning av biogasanläggningen, Kungsängens gård
The purpose of this thesis was to make an energy survey and quantify energy flows of individual unit operations associated with the biogas production in Uppsala Vatten och Avfall AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would be identified and analyzed. The objective of this energy survey was to obtain a detailed understanding of the energy use in the biogas production.The energy survey was divided into two parts: electricity and heat. Each part was treated separately and with somewhat different approach. To estimate the electricity usage during the projcet the rated power of each selected unit operation was noted and multplied with thenmeasured time of usage.
Energikartläggning vid biogasanläggningen, Kungsängens gård
The purpose of this thesis was to make an energy survey and quantify energy flows of
individual unit operations associated with the biogas production in Uppsala Vatten och Avfall
AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would
be identified and analyzed. The objective of this energy survey was to obtain a detailed
understanding of the energy use in the biogas production.
The energy survey was divided into two parts: electricity and heat. Each part was treated
separately and with somewhat different approach. To estimate the electricity usage during the
projcet the rated power of each selected unit operation was noted and multplied with the
measured time of usage.
Infallsvinklar och angreppssa?tt fo?r en svensk livsmedelsstrategi : En utredning av angreppspunkter och betraktelsesa?tt hos livsmedelsstrategi-intressenter samt ha?llbarhetsaspekter av dessa.
Understensho?jden is Stockholm's largest eco-village which was built in the early 1990s with the vision of enabling ecological living for people. However the ecovillage is no longer considered as environmentally friendly because of its relatively high energy consumption, and non-updated energy system. The purpose of this study is therefore to investigate how Understensho?jden should reduce their energy consumption and upgrade its energy system by using Blower-Door, IR-camera and Design Builder.
Hur påverkar energi- och proteinrik kost intaget av energi och makronutrienter?
Today 70 percent of the people residing in nursing homes are undernourished. One way to avoid that an individual is affected by malnutrition it is a necessity that the meals is customized after special needs current among other things as energy and protein. Food record is a method that can be used to examine and evaluate if an individual is getting sufficient nutrition and energy to cover the daily needs. For those suffering from malnutrition it is recommended to eat energy and protein enriched diet.AimsThe aim is to compare the intake of energy and macronutrients in a group of elderly people living in a nursing home in southern Sweden before and after the introduction of an energy and protein enriched diet based on newly developed recipes.MethodsFood record was made during four days. Food record means that everything that is consumed by an individual is noted precisely.
Utvärdering av miljönytta för olika miljöcertifieringssystem för byggnader : En jämförande fallstudie på Swecos kontor i Stockholm, Göteborg och Malmö
This thesis examines the environmental benefits resulting from the choice of environmental certification scheme, with focus on energy. This was carried out by studying the measures that were implemented as a result of the certification of Sweco's three largest office buildings in Stockholm, Gothenburg and Malmö. The office property in Stockholm has been certified with the Swedish Environmental Building, Gothenburg with the British BREEAM and Malmö with the U.S system LEED.The results from the study indicate that an environmental certification can reduce the energy consumption by up to 59 percent and the water consumption by 20 to 66 percent. However; the interviews, literature study and simulations in MATLAB indicate that the size and scope of these environmental benefits depend on several identified factors: the type of building and its conditions, system selection, grade level, the choice of indicators, the ambition of those involved and when in time the certification process begins. The comparison between Environmental Building, LEED and BREEAM showed that Environmental Building for the office property in Stockholm gave the largest environmental benefit in terms of reduced energy consumption thanks to several large measures.
Energiåtgång under tillverkning och produktion av byggnadskomponenter
This diploma work addresses the question of how much energy is spent whenmanufacturing the components of a building as well as of how much energy is used inthe production of a building. The object of the studies is BioCentrum at the SwedishUniversity of Agricultural Sciences in Ultuna just outside the city of Uppsala. The aimof the work was to investigate how much energy was consumed when manufacturingand production in relation to the management, how many years the production wasrepresented. It was also a study in how mature the construction industry is to answerhow much energy was consumed in manufacturing.In order to get these answers a question form was developed and sent to thesuppliers to BioCentrum. In this form they were to respond to the quantity suppliedto BioCentrum and the amount of energy was spent when manufacturing thecomponents.
Understensho?jdens framtida utveckling : ett arbete om energieffektiviseringar i ekobyn samt uppgraderingar av dess energisystem utifra?n ett ha?llbart perspektiv
Understensho?jden is Stockholm's largest eco-village which was built in the early 1990s with the vision of enabling ecological living for people. However the ecovillage is no longer considered as environmentally friendly because of its relatively high energy consumption, and non-updated energy system. The purpose of this study is therefore to investigate how Understensho?jden should reduce their energy consumption and upgrade its energy system by using Blower-Door, IR-camera and Design Builder.
Produktivitet och lönsamhet vid skörd av skogsbränsle i klen björkgallring :
The aim of the study was to compare productivity in first thinning of birch stands, when either energy- or pulpwood was harvested. The systems total profitability was also compared by including forwarding and chipping costs. A Gremo 950 HPVR harvester was used and the same driver was used under the entire study. During the pulpwood harvest a Logmax 4000b harvester head was used and a feller buncher head made by Silvatec was used during the energy wood harvest. Six study unit pairs were located in a birch dominated stand outside Ängelholm in Skåne.
Affärsupplägg biobränsle Västerbotten : en undersökning av större biobränsleanvändares syn på biobränslemarknaden i Västerbotten
The use of bio energy in Sweden has increased during the last few years and with every passing year, bio energy produces 3-4 TWh´s more energy than the previous year. The increase in the use of bio energy makes it an interesting prospect for forest companies to produce bio energy from the forest. Sveaskog has a fairly extensive bio energy programme, mainly in southern and middle Sweden. Their activity regarding bio energy in northern Sweden has been very restrictive or even non-existent. Because of this, during the winter of 2003-2004, Sveaskog initiated a number of degree projects with the purpose of looking at the use of bio energy in northern Sweden.
Energikartläggning av Försäkringskassans lokaler : rekommendationer för ett fortsatt energieffektiviseringsarbete
With new energy directives in place, the Swedish Social Service (SSS) stands beforethe challenge how to reduce the energy demand in its locales. It is a complex matter,as the locales are rented from various property owners and it becomes a question ofhow to reduce the operational electricity and influence the property owners to workmore with energy efficiency. This thesis takes a balanced research approach in threeparts. Firstly a qualitative part in form of interviews with personnel at the SSS and itsproperty owners, secondly a quantitative part of descriptive nature in form of energystatistics and thirdly a literature review of Energy Management (EM) Supply ChainManagement(SCM), Green Supply Chain Management(GSCM) and EnviromentalPerformance Indicators (EPI). This in order to be able to give normativerecommendations of how the SSS should act to reduce its energy consumption in itslocales and provide new insights on how EM, SCM, GSCM and EPI can be applied ineffect.
Analys och kvantifiering av energieffektivisering inom fjärrvärmesektorn
The Swedish Government has set a target to reduce energy consumption through energy efficiency within the construction and real estate sector. The purpose of the study is to examine how energy efficiency within this sector could affect the district heating volume in the future, on basis of Vattenfalls district heating system in Uppsala.An Excel model has been created to study how energy effficiency measures affects district heating demand in buildings by 2045, based on technical and economicalconditions. Furthermore, an interview study has been conducted to examine incentives for district heating customers to invest in energy efficiency measures.Result of the Excel model shows that the district heating volume of Vattenfall in 2045 is expected to 931 GWh, which corresponds to a volume decrease of 10,6 %. Based on the study?s theoretical framework only 15 %, 1 024 GWh, of the technical-economical potential is assumed to be implemented.
Osäkerhet i energisimuleringar av flerbostadshus : Analys av fem nybyggnationer
Since energy simulations are used to verify that projected residential buildings will reach the current energy requirements it is important that the results are reliable.This report investigates the extent of uncertainty in energy simulations, estimates the causes of the uncertainty and its economic and environmental consequences.The method used in this report is based on three validation methods; empirical validation, analytical validation and comparative validation. The analysis was carried out for five multi-family dwellings in Uppsala with installed meters for energy measurements. One of these objects, Klockarlunden, was studied in more detail than the others.The results show that the deviations are between 10 and 29% for the studied objects, which means that the uncertainty is estimated to be at least 29%. All simulations underestimate the buildings need of energy. The simulation for Klockarlunden can predict the energy consumption to be within the range of 46-98 kWh/m2year with 90% confidence level based on the current uncertainty.
Utvärdering och åtgärdsförslag av energianvändning i kontorsbyggnad
AbstractEmbla 5 is an office building which has done a large improvement. The clients of this building has made an order of WSP and the student Anders Kempe to calculate the use of energy for the building, and after that result proposing further measures which can decrease the energy use of Embla 5.The ground for this report is when calculation of the present energy use of the building is stated. To make that information of a number of parameters such as envelope, the heating system and ventilation has been located and set in to the simulation program IDA ICE which calculate the energy use.To improve the energy use further this project has been concentrated to change the system of ventilation. Today the ventilation system is of the kind CAV (constant air volume) and the air flow is dimensioned for after recommendations from BBR and Arbetsmiljöverket in the office spaces. Consider that Embla 5 is an office building where the people only staying for 8-10 hours/day so was the ide to see how much energy saving if the air flow is reduced the time people not being in the building.