Sökresultat:
3010 Uppsatser om Energy Performance Certificate - Sida 56 av 201
Simulering av värmebehov för kombinerad kontors- och laboratoriebyggnad utan traditionellt värmesystem
In this Thesis the possibilities of designing a larger building that is very energy efficient in the sense that it would not need a conventional heating system are discussed. Solar radiation transmitted through the windows, internal heat from occupants, lamps and electric appliances inside the building and heat recovered from the ventilation system then have to be sufficient for the heating of the building. This study is of general interest since the property company, Akademiska Hus, plans to use this study as a first step in determining if this technique could be used in the future and thus be worth further investments. A building without a conventional heating system of the size investigated in this project has not yet been built.The energy needed for the heating of the building was simulated using VIP+.The conclusions from the study are that it is possible to build large buildings without any conventional heating system. This could be achieved in many different ways, for example by lowering the inside temperature or by using better windows and heat recovery system with higher efficiency.
Sekundärnät för lågtempererad fjärrvärme
Lower energy use in buildings is a result of increasingly stringent energy requirements across Europe. When conventional district heating technology is used in areas with low energy consumption heatlosses do not fall even though the amount of energy delivered is reduced. This reduces income for thedistrict heating company. To maintain their economic viability the district heating companies? majorchallenge is to implement new solutions that minimize heat loss.
Hållbar energi : - Ett initiativ till utveckling av bränsleceller i Sverige
In the world we live in today the environmental issues has become increasingly important, and we have begun to realize that we can not continue to use fossil fuels at the rate we do. When it comes to generating electricity we are constantly trying to come up with cleaner and more efficient solutions. The fuel celltechnology is one such alternative and has been around for over 100 years. Yet, it is not until now that the world has started to notice this great technology. The fuel cell has been developed in several areas and can today be used for handheld electronics, vehicles and small settlements.
Key Performance Indicators inom en industriell inköpsorganisation
Världen befinner sig i en ekonomisk kris och många företag jobbar dagligen med effektivisering. Det finns många företag som oroar sig över framtiden och alla måste se över sina kostnader så man klarar sig även om en rådande lågkonjunktur råder. Ett sätt att förbättra effektivisering är att förnya inköpsavdelningen, att göra bättre inköp helt enkelt. Examensarbetet har utförts på LKAB som jobbar med ett effektivitetsprojekt som heter LKAB 370. Det innebär att man ska effektivisera företaget på så många sätt som möjligt Målet med LKAB 370 är att uppnå ett nytt kostnadsmål på 370 kr/ton järnmalm.
Undersökning av solcellspotentialen för golfverksamheter i Sverige
Photovoltaic Systems in Sweden has longbeen heavily dependent on subsidies and grants to bring in a profit for the investor. Production of excess electricity is a major reason for this as the compensation for excess electricity today is low. However, there are businesses that have an electricityneed that are particularly suitable for solar electricity. These businesses have an electricity demand when the sun shines the brightest and if the Photovoltaic System is properly scaled, the excess electricity can be minimized. A golf club is that kind of a business and this thesis aims to examinate the solar power potential for golf businesses in Sweden.Nine golf clubs was selected from different locations in Sweden.
Utveckling och konstruktion av dämpare och låssystem för vågkraftverk
The division of Electricity at Uppsala University is developing a wave energy converter(WEC) consisting of a linear generator connected to a bouy at the water surfacethrough a wire cable called the connection line.During extreme conditions, the wave power plant will experience forces up to 500kN, which lead to unnecessary wear and will ultimately cause the failure of theconverter. To prevent this there is a need for a damper.The wave energy converter works at a maximum efficiency when the translator?sare centered with respect to the stator. Due to tidal movements the position of thetranslator can deviate. There for a mechanical divice that will compensate for this isneeded.This report describes the further development of an earlier project where a tidalwave compensator for a wave energy converter of Seabased AB was developed.
Projektering av ett småhus med fördjupning i uppvärmningssystem
This report aims to examine the design of a passive house. The design addresses the selection ofmaterial, sizing and selection of both building services systems and building technical features suchas load-bearing framework and moisture control. Interior layout is designed for a family of twoadults and one child.A big part of the report is devoted to an in-depth comparison of three different wall constructions ofpassive house standard. The structures that have been compared are a lightweight timber structure, aheavier concrete structure and a sandwich wall of the brand Weber Leca. The report covers variousaspects such as air flow, wall thickness, the risks associated with the construction, U-value, thermalbridges, power consumption, price, and assembly costs.
Utformning & placering av vädringskanaler i ett passivhus, drivet av naturliga krafter
A passive house in Norra Djurgårdsstaden drawn by Tengbom Arkitekter is going to be built. A shaft for airing is needed for a few apartments in the house.The airing shaft is designed for a few two room apartments in the house, which are not able to achieve satisfactory airing, as their outer walls are facing a single direction. The other apartments on the same floor are corner apartments. These apartments do not have the same difficulty with airing since they have their outer walls in different directions, with different pressures at the facades. The airflow in the airing shaft is supposed to be driven only by natural forces, by the sun. The purpose of natural driven forces is to achieve low energy consumption for the house.In this thesis, a design of the shaft for airing has been developed.Initially an open shaft for all apartments was analyzed.
Passivhus : En jämförelse mellan olika byggnadstekniska lösningar för ytterväggar
This report aims to examine the design of a passive house. The design addresses the selection ofmaterial, sizing and selection of both building services systems and building technical features suchas load-bearing framework and moisture control. Interior layout is designed for a family of twoadults and one child.A big part of the report is devoted to an in-depth comparison of three different wall constructions ofpassive house standard. The structures that have been compared are a lightweight timber structure, aheavier concrete structure and a sandwich wall of the brand Weber Leca. The report covers variousaspects such as air flow, wall thickness, the risks associated with the construction, U-value, thermalbridges, power consumption, price, and assembly costs.
Visuell Perception : En studie av visuella faktorer kring ett musikaliskt framträdande
The essay investigates the visual element as seen by the audience and artist to be of greatest importance to a musicalperformance. The study was conducted in the form of a field work which included doing interviews with artists, surveys of the audience and interpretive observations of live performance. The fieldwork was conducted in three different environments in which I found myself on the spot and performed the various stages included in the field work. It was done to create a surface that could be used in an essay, and through that use this material to compare and analyze my results and in the end be able to answer my questions. I started from eight different factors which all could beexperienced visually on stage.
Stomme i småhus ! : - En teoretisk studie av olika bärande vägglösningar !
This report aims to examine the design of a passive house. The design addresses the selection ofmaterial, sizing and selection of both building services systems and building technical features suchas load-bearing framework and moisture control. Interior layout is designed for a family of twoadults and one child.A big part of the report is devoted to an in-depth comparison of three different wall constructions ofpassive house standard. The structures that have been compared are a lightweight timber structure, aheavier concrete structure and a sandwich wall of the brand Weber Leca. The report covers variousaspects such as air flow, wall thickness, the risks associated with the construction, U-value, thermalbridges, power consumption, price, and assembly costs.
Beredning av köldbärare för komfortändamål i kontorsverksamhet : En studie i produktionsslag
The real estate company Ihus is facing an expansion of its comfort cooling in Noatun,Uppsala, to provide the buildings in the block with cooling. The buildings in Noatunare mainly used for office premises, where the requirements for an accepted indoorclimate is great. However, it?s uncertain whether Ihus should continue, as currently,producing comfort cooling by themselves using a compressor chiller, or if they shouldconnect themselves to Vattenfall?s district cooling net.The purpose of this report is to examine which technique of cooling is best suited forIhus and their buildings in Noatun. It should also work as a guideline for othercompanies facing the same problem as Ihus.
MAGISKA RUM : om scenografins roll i scenkonstverk för barn och unga
This thesis investigates the communicative role of scenography in the performing arts for children, with an aim to make the readers understand the ways in which a set design can be optimized so that a young audience can be able to interpret the play and its message.The art of scenography is complex and includes many elements. The research questions can therefore be grouped into three clusters: one artistic oriented (How does the scenographic process work and what is its relation to the scenic piece at large? In which ways may scenography be used to support the desiderate interpretation?), one audience oriented (Which work processes enhances the chances of creating dramatic art that is perceived as meaningful to the audience? On what premises can the semiotics of theatre be used in the performing arts for a young audience?) and last a cluster that focuses on Den magiska cirkeln (The Magic Circle) by ung scen/öst (What is told in the show and how is this portrayed in the scenography? Who is in the target group, and does the audience get the feeling of the performance as intended?).Den magiska cirkeln is used as a case study in the thesis in order to reflect the theoretical material. Methods in the case study includes performance analysis, a survey completed by 178 people in the audience and an interview with scenographer Anna Dolata. 14 performing analyzes of Swedish children?s theatre shows have been made in addition to the case study.The thesis analyses and compares two work logics; the internal logic and the external logic, and it is shown that meaningful interpretations are likelier to happen with an external logical point of view.
Finns det ett samband mellan börsnoterade företags resultat och dess värdering?
Background: What is a share and what determines the value of a company? This is a constant issue that many in the financial world are facing. Many argue that there has been some decoupling between stock valuation and how the company in question is developing operationally after the financial crisis that the world faced during 2008-2009.Problem: It is important to distinguish between the company and the share. A company that is good and well maintained may not be worth buying only because of it. The share is judged by other elements also.
Småskalig vattenkraft : Dagsläge och framtidsplaner
This study focuses on small scale hydropower in Sweden. This means plants with a capacity of up to 10 MW. The study has a special focus on plants with a capacity up to 2 MW. The study has three aims. It strives to describe the small-scale hydroelectric industry in Sweden.