Sökresultat:
675 Uppsatser om Energieffektivisering ventilation - Sida 9 av 45
Utvärdering av VAV i nybyggt kontorshus
VAV (Variable Air Volume) system has been studied in a newly constructed office-building. The goal for the study has been to evaluate how the ventilations system work in practice, if adjustments can be made to achieve an more energy efficient system and to evaluate if other alternative ventilation systems is to be preferred in the further.The degree project has been executed at Helenius Engineering Firm who is working with the environment, media systems, HVAC and energy in buildings. The building that has been studied is owned and operated by Akademiska hus.Literature studies, visits at site, inventory, review of system documentation, energy analyses, interviews, key figures, LCC, sand energy- and indoor climate simulations has been made to study the building. Where appropriate some tools from Six Sigma have also been used.How to achieve an energy efficient system and a pleasant indoor climate is studied with human health and well-being as base for the indoor climate requirements. Technical support systems such as ventilation systems have to be designed so that an acceptable indoor climate can be achieved.
Kompaktaggregat till Passivhus i Sverige
Kompaktaggregat är ett integrerat FTX- och FVP-system som används i passivhus. Vi har gjortenergiberäkningar i programmet VIP+ för att se hur kompaktaggregatet skulle kunna fungera ipassivhus i Sverige.De resultat vi har fått fram ur VIP+ visar att passivhus med ett installerat kompaktaggregat klararav att nå passivhuskraven ända upp till Skellefteå. De beräknade värdena understiger kraven förpassivhus, men en viss marginal behövs för att kraven ska nås även efter uppförandet avbyggnaden. Vi har även tolkat tekniska uppgifter på ett sätt som enligt oss har en positiv effektför passivhus på kallare orter. Därför tror vi inte att värdena för de tre nordligaste platserna ärhelt tillförlitliga.
Energieffektivisering i Bostadsrättsfastigheter
Med tanke på den senaste tidens klimatdebatt har energieffektivisering blivit ett aktuelltämne. Inom bostadssektorn är potentialen att minska energiförbrukningen stor och blandflerbostadshusen är bostadsrätt den vanligast förekommande ägarformen. Studiensfrågeställning är följande: Vilka faktorer påverkar Halländska bostadsrättsföreningar attenergieffektivisera sina fastigheter? För att besvara problemformuleringen har olikapåverkande faktorer först identifierats utifrån tidigare forskning. Den insamlade teorin harsedan verifierats genom tre djupintervjuer med kunniga personer inom ämnet.
Modellering och energieffektivisering av befintligt markvärmesystem : Med fokus på väderlekens påverkan på ett markvärmesystems energibehov och potentiella styrmetoder för markvärme
Syftet med markvärme i stadsmiljöer är ofta att hålla gator, torg och andra relevanta markytor snö- och halkfria, till nyttan av att kunna undvika snöröjning. Markvärme är dock en dyr affär och problematisk för miljön.Tekniska verken i Linköping AB är en kommunalägd koncern som bland annat producerar och levererar fjärrvärme, fjärrkyla och markvärme som en tjänst inom divisionen Energi. Företaget har sett ett behov att utreda möjligheten att energieffektivisera markvärmen, då man ser att slutanvändningen av energi är för hög och kunderna inte är beredda att betala de priser som satts för markvärmen.Examensarbetet har syftat till att kartlägga dagslägets markvärme i Linköping och utreda förändringsmöjligheter som kan leda till en energieffektivisering och hur detta påverkar företagets produktion och kostnader.Kartläggningen av markvärmen har visat att det finns ett behov av att standardisera och förbättra styrningen i markvärmesystemens undercentraler. Förslag har därmed tagits fram att komplettera befintliga styrsystem, som har marktemperaturgivare, med fuktgivare, nederbördsgivare och att med den utrustningen inrikta sig på prognosstyrning för att minska slutanvändningen av energi då behovet av markvärme är litet.Energieffektiviseringsåtgärden har utretts med hjälp av en klimatmodell, utvecklad i ett beräkningsverktyg för simulering av styrmetod och väderlek. Modellen är ett marktvärsnitt som representerar markvärmens konstruktion och styrning och tar hänsyn till väderlek som påverkar markytans temperatur.
Energieffektivisering i en bostadsrättsförening - En utredning av HSB Honungskivlingen, Borås
Olyckor är vanliga inom sjöfarten. För den akut medicinska behandlingen finns god beredskap ochtydliga riktlinjer. För den akut psykiska behandlingen saknas klara råd. Denna studie undersökerrådande riktlinjer och praxis för det psykiska stödet. Studien syftar på att klargöra vad det finns förmöjlighet att utveckla det psykiska stödet i det akuta skedet efter en incident ombord på svenskafartyg.
Kompaktaggregat till Passivhus i Sverige
Kompaktaggregat är ett integrerat FTX- och FVP-system som används i passivhus. Vi har gjortenergiberäkningar i programmet VIP+ för att se hur kompaktaggregatet skulle kunna fungera ipassivhus i Sverige.De resultat vi har fått fram ur VIP+ visar att passivhus med ett installerat kompaktaggregat klararav att nå passivhuskraven ända upp till Skellefteå. De beräknade värdena understiger kraven förpassivhus, men en viss marginal behövs för att kraven ska nås även efter uppförandet avbyggnaden. Vi har även tolkat tekniska uppgifter på ett sätt som enligt oss har en positiv effektför passivhus på kallare orter. Därför tror vi inte att värdena för de tre nordligaste platserna ärhelt tillförlitliga.
Energieffektivisering i livsmedelsbutiker i Stockholms skärgård
Många butiker i glesbygden har tvingats lägga ned på grund av hård konkurrens från större butiker i städer och handelscentrum. De har dock ofta en samhällviktig roll som exempelvis ombud för apotek och post och en nedläggning bör om möjligt undvikas. Minskade energikostnader resulterar i att butikers chanser att överleva ökar. Projektets syfte var att föreslå åtgärder som kan reducera energianvändningen i fyra butiker i Stockholms skärgård. En energimodell för butikerna utvecklades för att simulera energianvändningen samt effekter av åtgärder, enskilt och i paket.
"Att känna sig som något lätt fjäderaktigt" : äldre människors upplevda hälsa och vårdande som stödjer deras hälsoprocess på särskilt boende
Aim: The aim of this study was to describe intensive care nurses? experiences communicating with patients during mechanical ventilation.Methods/design: A qualitative interview study. Interviews where analyzed using descriptive content analysisSetting: Nine intensive care nurses from two different intensive care units were interviewed using a semi structured interview guide.Background: Past research has shown that patients during mechanical ventilation in the intensive care unit, feel very vulnerable and the helplessness of being unable to speak. These patients feels that they are completely dependent on the nurses and their competence. It has been shown to be very important that the patient feels included, acknowledged and respected.Results: The analyzed data resulted in a theme; through communication strive to preserve patients´ dignity and three main categories; create relationship to the patient, minimize patients´ vulnerability and don´t give up.
Påverkan på energianvändning och termisk komfort vid reglerinstabilitet
The purpose of the study is to investigate the possible effects of an unstable ventilation system and its influence on energy use and thermal comfort. The report also explores how qualified personal working with HVAC view and handles system control.In order to meet the requirements in energy efficiency and a comfortable indoor climate control regulation is a prerequisite. With optimized increased complexity of the climate systems, it becomes more challenging to control the system and the risk of unstable control increases. No previous studies about what affect an unstable system can have on energy use and thermal comfort have been found.The report is based on several tests were the controlling variable has been increased until the system becomes unstable. Two different types of unstable systems have been investigated.
Energieffektivisering av Badmintonstadion AB i Umeå
Badmintonstadion i Umeå vill söka bidrag hos Umeå kommun för att genomföra energieffektiviserande åtgärder. Stadion är byggd år 1990-1991 och har 13 badmintonbanor fördelat över tre hallar, ett gym, omklädningsrum och en mottagning för sjukgymnastik. Umeå Energi försörjer lokalen med el och fjärrvärme. Syftet med detta arbete har varit att undersöka vilka energieffektiviserande åtgärder som är mest ekonomiskt lönsamma. Lokalen förbrukade under år 2013 234 MWh el och 134 MWh fjärrvärme (graddagskorrigerad).
Passivhus i Karlstad : En jämförelse med hus byggda på traditionellt sätt
Passivhus är en vidareutveckling av ett energisnålt hus, där man genom extra tjock isolering,hög kvalitet på dörrar och fönster samt husets planlösning minimerar beroende att köpa energiför uppvärmning. Passivhus har krav på uppvärmningsbehovet samtprimärenergiförbrukningen. En princip för passivhus är att de inte ska vara krångligare ellerobekvämare att bo i än vanliga hus.Lindås Park är ett bostadsområde som består av 20 st. radhus som ligger en bit utanförGöteborg. Radhuset klarar kraven för ett passivhus, det enda värmesystem som är installeratär en eftervärmare till FTX-systemet på 900 W.De passiva hus som byggts i Sverige har gemensamt är att de ligger i södra delen av Sverigeeller nära kusten, dvs.
Energieffektivisering i sambandmed renovering : ? Analysmodell för energibesparande åtgärderutifrån ett företagsekonomiskt perspektiv
Rising energy prices and higher energy demands have led to an increased focus on energy efficiency, in particular in the real estate business, where high potential for energy savings exists. Within the next few years, buildings that were constructed in the sixties and seventies will be in need of renovation. One of the challenges of these renovations will be to improve energy efficiency. A real estate company that is facing this challenge is Uppsalahem AB, based in the city of Uppsala, Sweden. This study focused on analyzing energy efficiency measures when renovating old buildings.
Klimatsimulering av ett kontorsrum : Hur de termiska stigkrafterna påverkar ventilationseffektiviteten
AbstractIn urban societies people spend more and more time indoors, which put great demands on the indoor environment. If the ventilation is to manage the removal of unwanted substances in the indoor air, a good mixing of the air is required. The question arises that, whether the buoyancy forces will counteract a good mixing of the indoor air or not?This report aims to clear up the difficulties whether you need to consider the buoyancy forces or not, when adjusting a ventilation unit. For studying the indoor mixing of the air a two dimensional model is constructed in COMSOL Multiphysics.
Stäng dörren tack : En observationsstudie om dörröppningar på operationssal
Bakgrund: Flera studier beskriver vikten av att minimera dörröppningsfrekvensen på operationssalarna. Högre frekvens av dörröppningar leder till försämrad ventilation på operationssalen, vilket i sin tur kan leda till vårdrelaterade infektioner.Syfte: Syftet med denna studie var att på en operationsavdelning observera frekvensen av dörröppningar under pågående operation, varför och av vem de öppnades.Metod: Metoden var en kvantitativ deskriptiv observationsstudie med tvärsnittsdesign. Personalen på en operationsavdelning i Mellansverige observerades under pågående operationer. Observationerna utfördes sex vardagar i januari 2013 och valdes från operationsprogrammet.Resultat och slutsats: 22 observationstillfällen observerades, 11 från vardera konventionell respektive infektionskänslig kirurgi. Studien visade att dörröppningsfrekvensen var högre vid konventionell kirurgi jämfört med infektionskänslig.
Ventilation i häststall
Dagens sporthäst lever idag under människans ansvar i stallar. I stallarna förekommer luftföroreningar, den med störst påverkan på hästen är luftburna partiklar som huvudsakligen härrör från strö och stråfoder. Föroreningarna kan orsaka skada i respirationsorganen, vilket medför att hästen får en minskad prestationsförmåga och de kan leda till allvarlig sjukdom. För att bli av med föroreningarna i stallet behövs en väl fungerande ventilation, med tillräckligt flöde, som kontinuerligt kan byta ut luften i stallet.
Förståelsen för problematiken med partikulära föroreningar i stalluften är dålig, bland annat för att även starkt förorenad luft kan upplevas som frisk.