Sök:

Sökresultat:

10084 Uppsatser om Electric energy storage system - Sida 2 av 673

Termoelektrisk lagring i system med fjärrvärmeproduktion

With increased deployment ofintermittent renewable energy, such aswind and solar power, energy storagebecomes necessary to help reduceproduction peaks. Thermoelectric EnergyStorage is a method still in researchphase, which stores electricity in hotwater at a temperature of 120 ° C. Thisthesis aims to examine whether theThermoelectric Energy Storage would bepossible to integrate into existingpower generation such as a combined heatand power plant, and how the technologypotentially could function in theelectricity market. ThermoelectricEnergy Storage consists of a chargingprocess and a discharging process, bothoperating by the working fluid CO2. Toincrease the efficiency of theThermoelectric Energy Storage, wasteheat from the district heating networkis integrated.A model of the Thermoelectric EnergyStorage has been developed and it wascalculated by thermodynamic propertiesof the working fluid, CO2, in thevarious process steps.

Lagring av kyla i bergrum : Undersökning av ett nedlagt oljebergrum

This thesis considers the use of an oldrock cavern as thermal energy storage.With a large system of differentchillers a model was created to find anappropriate future system. There aremainly two trajectories to take. Eitheran installation of chillers needs to bemade or the rock cavern can be used tomeet the future demand of districtcooling in Solna, Sweden. Additionallythis thesis investigates the possibleuse of different techniques to utilizethe phase change energy of water.Simulation shows that it?s possible toutilize the phase-change energy of afluid; however it?s not economicallyfeasible due to the thermodynamiceffects on the Carnot cycle.

När ska dieselelektrisk framdrift av fartyg väljas?

Diesel electric propulsion is in many ways a good alternative to conventional shaft propulsion, both economically and environmentally. There are also many other good side effects which need to be considered, i.e. better manoeuvrability, more efficient use of space and less noise on board. However, there are applications where diesel electric propulsion is not profitable. Large ocean going ships? profitability is much depending on fuel costs and the diesel electric alternative cannot compete on long journeys with large low speed engines.This thesis will treat the aspects of choosing between a diesel electric system and a classic mechanical propulsion system.

Hydraulisk och termisk grundvattenmodellering av ett geoenergilager i Stockholmsåsen

Geothermal energy can be extracted from an aquifer, where the groundwater is used as heatexchange medium while heat and cold are stored in the surrounding material in the aquiferand to some extent in the groundwater. Application of aquifer storage for the use ofgeothermal energy is mainly used in large scale facilities and is limited to sites with suitableaquifers in the form of ridges, sandstone and limestone aquifers.Löwenströmska hospital in the municipality of Upplands Väsby, north of Stockholm, islocated nearby the northern part of the Stockholm esker. This means that it can be profitableand environmentally beneficial for the hospital to examine the possibilities of aquifer storagein the esker material next to its property.The purpose of this master thesis has been to investigate if geothermal energy storage with aseasonal storage of heat and cold can be applied within Löwenströmska hospital?s propertyarea using groundwater modeling. A hydraulic groundwater model was constructed inMODFLOW based on a simplified conceptual model of the groundwater system.

Möjliga alternativ för att ersätta direktverkande el i flerbostadshus

I have in my thesis, examined the possibilities in terms of energy for a condominium association.To have an effective and good energy is becoming increasingly important with today's rising electric and oil prices. In my thesis I have used the condominium association Kärralyckan, which is situated in Falkenberg. The buildings at Kärralyckan are built in the mid-1970s, and are heated by electric radiators. The tap water is heated by an electric boiler.Based on that calculation I can show the various energyststem. The different solutions have been developed by contact manufacturers and installers through phone calls and e-mail.According to the results shows that geothermal heating has been a great solution for Kärralyckan.

Ökad resurseffektivitet i kraftvärmesystem genom säsongslagring av värme

Increased resource efficiency in an energy system could result in large economic and environmental benefits. Tekniska verken i Linköping AB (Tekniska verken) is responsible for the district heating network in Linköping. Their vision is to create the world?s most resource efficient region. An important step towards this vision is more efficient usage of produced heat, something which could be achieved through integration of a seasonal heat storage in the energy system.

Torkad eller gastät lagrad spannmål till värphöns : en fallstudie

The purpose with this study is to compare different systems of grain storage from a financial point of view. Grain that is supposed to be fed to laying hens. The systems that were compared were different airtight storage of grain and a system of conventional storage. To make this case study I choose to compare four different systems. In the case study there was one system with bin drying of the grain, two systems with airtight storage of the grain and one system where you buy dried grain during the season. I made several of capital investment appraisal where I found the cost of each system, then I took the cost and divided it with the total grain use and calculated the cost for each kilogram of grain, and also the cost of the feed. Then I compared the cost from my case study with the cost of buying feed. All the systems except for one, gave a lower cost for the hen feed than buying feed from a dealer The best system, witch were bin drying lower the cost with about 80 000:- SEK.

Energieffektiv torkning av kläder : en studie av torktumlare med varm- respektive kallvattenanslutning

Tumble dryers and drying cabinets have to a large extent replaced the traditional way of drying clothes outdoors. They are faster, more convenient, require less space and can be operated regardless of weather conditions. This replacement has significantly increased residential energy consumption, due to the fact that tumbles dryers consume large amounts of electrical energy. In the USA 9 % of the households electric energy is consumed when drying clothes. Over 4 million tumble dryers are sold in Europe each year and 20 % of the residential electricity consumption in Sweden is used drying and washing clothes.

En analys av centralkylan i Slakthusområdet i Stockholm

In Stockholm, Johanneshov the Slaughterhouse area (Slakthusområdet) can be found. A number of companies have gathered there providing the Stockholmers with meat products. This area has a great need for cooling to supply large cold storages. To facilitate this, a central cooling system has been built, supplying the area with effective and safe cooling.The aim of this master thesis study is to give hints to energy efficient and reliable changes that can be put in place at a low marginal cost depending on the future activities in the area. The suggested changes will be presented to the company Bravida (managing the system), which also desires a deeper understanding of the energy flows through the central cooling system.Firstly visiting the site with proper guidance, we have then tried to understand the function of the system including which machines and media that are used.

Utvärdering av energieffektiviseringsåtgärder på Bokelundskolan i Växjö

The purpose with this report is to examine how the implemented energy efficiency measures on Bokelundskolan in Växjö have had impact on the energy use. The measures which have been implemented are, new ventilation system, new heating system, optimized adjustment of the heating system, new windows with U-value 1.2 and lower window height, insulation under windows and in the crawl space. The school's energy use before and after rebuilding has been calculated with the calculation program, Vip-Energy 1.5.5.Calculations of energy use for the school with windows on U-value, 0.9 and 0.7 have also been done. The replacement of windows has been studied from a cost perspective. The conclusion is that the exchange of heat and ventilation system was the biggest contributor to reduced energy use on Bokelundskolan.

Enegiutredning Hotell Princess

This report will show the energy usage of Hotel Princess in Sandviken, Sweden. When the hotel changed owner an examination of the hotels heating, ventilation and sanitary systems were done. The report showed flaws in the ventilation system, and is why the new owner wanted a closer look at the energy use of the hotel. The original building was built in the 1930s and two major extensions have been built, one in the 1950s and the most recent in the 1980s. An assumption made is that the building parts were built to the restrictions during the time. Activities on the hotel include sleep over, conference, night club, massage and swimming in the hotels pool section.

Kylbehovet hos ett batteribaserat elenergilager : Med avseende på kyldistribution, drifttemperatur, klimat, isolering och termisk tröghet

Under 2011 började MacBat AB ta fram ett elenergilager kallat Macbat Energy Storage System (MESS), vilket är uppbyggt av 360 stycken tvåvolts bly-syrabatterier inhysta i ett 20 fots container. Då bly-syrabatterier är känsliga för värme är den här studien inriktad på att utreda hur stort kylbehovet blir under olika förutsättningar där kyldistribution, drifttemperatur på batterierna, klimat, isolering och termiska tröghet är varierande parameterar. Det ska även avgöras vilken konfiguration av kyldistribution och isolering som ger lägst kylbehov för de studerade klimaten, vilka är av varmtempererad, arid och tropisk karaktär.För att besvara studiens två mål togs fyra matematiska modeller fram i SIMULINK. Två luftkylda och två vattenkylda där en av varje var isolerad med 100 mm mineralull medan den andra var oisolerad. För samtliga modeller varierades drifttemperaturen mellan 25 ? 35 °C och de studerade klimaten utgjordes av Phnom Phen, Kambodja, Djibouti, Djibouti, Bagdad, Irak samt London, England.

Bioenergi från röjningsgallringar : en jämförande studie av fyra flödeskedjor från avlägg till förbrukare

When the Swedish Forestry Act was changed in 1994, brushing of young stands became non mandatory. Since then the annual need for brushing in the country has increased by about 100 000 hectares per year. In later years the price for biomass energy has increased to the same level as pulp wood. The high price on biomass energy and the large areas of stands in the need of brushing has created a new market with its own technical, economical and environmental conditions. There is a development of various techniques to manage the forestry stands with late brushing.

Matningssystem för pellets

In today's society, the availability of energy plays an integral part in our everyday lives. Unfortunately, the price of energy in Sweden has increased in recent decades. A large part of our energy consumption goes to heating modules for houses, where heating methods that depend on energy sources such as electricity, district heating, fuel oil, gas and biofuels are the most common ones. During the winter period, the increase in energy costs becomes significantly evident, especially for small property owners. This increase in energy cost is most noticeable for home owners with electric heating.This thesis is written at the Halmstad University, in cooperation with a company, which makes parts of this thesis confidential.

Strömkontroll till aktiva magnetlager med noggrann och störningsreducerad strömmätning

There is always a need for more effective ways to store energy in order to reduce the human impact on the environment. One step on the way can be the use of flywheels as kinetic energy storage devices. Low frictional losses are essential for a flywheel to be effective. To minimize these losses active magnetic bearings (AMB) can be used to keep the shaft centered instead of the more conventional ball-bearings. AMBs use actuators and a fast control system that needs correct and noise-free measurement data of the shaft position and the current in the actuators to work properly.This thesis explains the process of constructing power electronics and a current measurement system for active magnetic bearings (AMB).

<- Föregående sida 2 Nästa sida ->