Metoder för lastprioritering i fjärrvärmecentraler
A problem in the field of district heating is the oil burners needed to provide power when a peak load occurs. One possible way of reducing the needed amount of oil is to reduce the power demand for space heating in the district-heating substations when the need for district heating water exceeds a certain limit. This can be done by use of a locally working controller function.In this Thesis the options concerning load priority are evaluated. To evaluate the potential for using controller functions concerning peak load priority an experiment was brought out in a chosen district-heating substation. The impact on the indoor thermal comfort during a heat reduction was also taken into account.
Inventering av processvattenbalans : fastställande av fjärrvärmedistributionens läckage inom Vattenfall Värme Uppsala AB
Heat is distributed to the district heating customers through pipes with water as a heat carrier. The district heating system is complex. To decide what is leakages from the district heating net versus what is the water consumption of the plant, is difficult.
Therefore, the purpose of this master thesis is to establish a model where the district heating net?s leakages but also the water consumption of the plant can be followed
daily. The project is performed at Vattenfall´s district heating power plant in Uppsala.
Information is gathered through discussions, drawings of the plant and guided tours of the plant.
Småhuset ? val av bergvärme, fjärrvärme eller pellets
This thesis describes the new construction of a small house and it includes studies of three heating systems: geothermal heating, district heating and pellet. The purpose of this thesis is to project a small house which can manage Building Regulations, BBR conditions and then examine three possible heating systems for the small house. This thesis is a literature study which gives an understanding of the heating systems technical structure, properties and costs. An empirical study completes the literature study by giving a deeper understanding of district heating costs and pellet costs. The empirical study contains two interviews, one of which was conducted in a district heating corporation and the other interview was conducted in a pellet corporation.
Sänkt returtemperatur : Potentiell besparing i fjärrvärmesystem
Optimizing energy systems is, in Sweden, as in many other countries, of growing interest. District heating systems are no exception. In 2012, 285 out of 290 municipals in Sweden had district heating in use and the majority of these systems have a higher return temperature than that which is possible with an error-free substation of day current technology. To, when possible, lower the return temperature is a way of increasing the effectiveness of the district heating system.This study means to investigate, through simulations and calculations, how big of a reduction in production cost a lower temperature in the city of Ystad?s district heating system would correspond to.
Utveckling av ny produktfamilj med handskar för användare inom street- outdoor segmentet. : En liten bit av naturen till staden, en liten bit av staden till naturen
This thesis describes the new construction of a small house and it includes studies of three heating systems: geothermal heating, district heating and pellet. The purpose of this thesis is to project a small house which can manage Building Regulations, BBR conditions and then examine three possible heating systems for the small house. This thesis is a literature study which gives an understanding of the heating systems technical structure, properties and costs. An empirical study completes the literature study by giving a deeper understanding of district heating costs and pellet costs. The empirical study contains two interviews, one of which was conducted in a district heating corporation and the other interview was conducted in a pellet corporation.
Analys och kvantifiering av energieffektivisering inom fjärrvärmesektorn
The Swedish Government has set a target to reduce energy consumption through energy efficiency within the construction and real estate sector. The purpose of the study is to examine how energy efficiency within this sector could affect the district heating volume in the future, on basis of Vattenfalls district heating system in Uppsala.An Excel model has been created to study how energy effficiency measures affects district heating demand in buildings by 2045, based on technical and economicalconditions. Furthermore, an interview study has been conducted to examine incentives for district heating customers to invest in energy efficiency measures.Result of the Excel model shows that the district heating volume of Vattenfall in 2045 is expected to 931 GWh, which corresponds to a volume decrease of 10,6 %. Based on the study?s theoretical framework only 15 %, 1 024 GWh, of the technical-economical potential is assumed to be implemented.
Energisäkerheten för fjärrvärmeanläggningars bränsletillförsel i Mälardalsområdet
There are several energy systems in the Swedish society and to ensure the comfort and health of the citizens it is of importance that the different energy systems are functioning properly. District heating is one of these energy systems and many household depend only on district heating to warm up their homes.
District heating is dependent on several processes where every step needs to function in order to deliver the produced heat to the end consumer. Previous studies have investigated the distribution of district heating and how to make customers choose district heating as their heating method. The supply of fuel to the district heating plant has not been studied as much, even though it is an important part of the whole system. This thesis is a part of the project NORD-STAR (Nordic Strategic Adaption
Research), which has focused on climate adaption in the Nordic countries.
En kombinerad Organisk Rankinecykel och värmepump integrerat med ett fjärrvärmesystem : Där värme- och elproduktion samt lönsamhet studeras och avfall är huvudbränslet
The demand for district heating is expected to decrease in the future, due to competition from heat pumps and energy efficiency measures in buildings. Development of existing district heating systems is therefore necessary for district heating companies to maintain market shares. This Master?s thesis describes and investigates the heat and electricity production and profitability of a combined Organic Rankine Cycle (ORC) and heat pump that is integrated with an existing district heating system. The studied district heating system is utilizing heat from waste incineration. In Sweden waste constitute 20 % of the fuel mix used in district heating systems, and this share is expected to increase in the future.
Projektering av ett småhus samt ekonomisk jämförelse av värmesystem
Design of a house requires knowledge of both technology and economics. Heating and ventilation shall be designed, costs are calculated and estimated and requirements must be fulfilled. Which heating system is to be elected is also a difficult choice, especially with rising energy prices as a factor.The choice of energy system is not always given, because it depends on several factors. Below is a comparison between district heating, geothermal heat pump and electric boiler from an economic standpoint. In a previous report appears district heating and geothermal heat pump as the best options.
Life Cycle Cost : Studie om LCC som verktyg att utva?rdera geoenergianla?ggningar
Life Cycle Cost, often abbreviated as LCC, is a common tool for comparing the total cost of different alternatives, such as heating and cooling methods. Common heating and cooling methods in Sweden are geothermal energy, district heating and district cooling. This report aims to evaluate how different heating and cooling methods differ from each other while being applied on three different types of buildings, using selected LCC-models. Information about the selected LCC-models wasretrieved from each separate model and its website. Reports and agencies were used as sources for information about the heating and cooling methods.
Vad påverkar fjärrvärmepriser i Sverige?: En ekonometrisk analys
The purpose with this thesis is to analyse different factors that can explain district heating prices for energy companies in Sweden. We are further interested in examining if the prices is affected by the use of industrial waste heat in their production and the company?s ownership structure. The method applied is a multiple regression analysis using a panel data set of 50 companies over 5 years (2008-2012). The data used is yearly data obtained from the Swedish district heating association.
Morgondagens effektiva fjärrvärme : En beskrivande litteraturstudie
This report is made as a literature review, focusing on the work done to increase understanding of efficiency in the categories of substations and secondary heating systems, with respect to the deviation from the theoretically possible cooling off in the distribution network as well as the economic benefit that appear. The main purpose of a considerable part of the literature used in this report addresses the issue of identifying individual causes of reduced cooling in district heating systems. These literature resources have been compiled and summarized as part of the report.The technology of district heating is associated with benefits such as better use of the energy in a fuel. This is the case of cogeneration plants where serial generation of electricity and thermal energy increases efficiency compared with the parallel generation where heat is generated locally and electricity is generated centrally. Serial generation thus allows for lower primary energy demand.
Energieffektivisering i ett verkstadsföretag : En analys av energibesparande åtgärder samt uppvärmnings- och kylsystems driftkostnader och koldioxidutsläpp
The energy use in a workshop company has been examined in this work in order to find areas for energy efficiency improvement. The combined oil and electricity heating in the company were compared with other alternative heating systems including cooling of the premises in following combinations:Ground source heat pump for heating and coolingDistrict heating and absorption coolingDistrict heating and low temperate surface water coolingEnergy use, operation costs and carbon dioxide emissions were calculated for the current heating systems and the three alternatives including cooling. The ground source heat pump for heating and cooling decreases bought energy with 34 MWh annually compared to current heating only. The district heating and low temperate surface water cooling has the largest reduction of operation cost and carbon dioxide. The operation cost decreases with 42 kSEK and the carbon dioxide with 43 metric ton CO2 annually.
Fjärrvärme - ny lokalisering av kraftvärme i Enköping
The municipality of Enköping is presently working out a new layout plan for the town of Enköping and new residences are planned in the harbour area. Because of these plans, the municipal energy company ENA Energi may have to move its location from the harbour to another part of the city.The aim of this degree project is to investigate the possibility of building a new CHP plant in another area of Enköping. The future demand on district heating and infrastructure at the new location have been projected. A new CHP plant has been dimensioned and economic analyses concerning the project have been made.Results show that the future demand of district heating in Enköping will differ a little from the present needs. In 2030, the district heating production is expected to be c.
Skadliga nollflödespunkter i Fortum Värmes fjärrvärmenät i Stockholm : En analys av dess förekomst och effekter
When several production units provide a district heating network, water is pumped from different directions. When the flows from the plants finally meet in the network, the water can be completely still. These places are called zero flow zones. In district heating networks with several plants, which also have different supply temperatures, large and frequent temperature fluctuations can occur when the zero flow zones move. This may cause wear on the pipes, a phenomenon called low cycle fatigue.For this reason it is important to examine where and when zero flow zones that cause temperature changes occur.