
Sökresultat:
117 Uppsatser om Cooling - Sida 5 av 8
Low Temperature Waste Heat Solutions : with proposals for energy technological actions based on Scania?s building 64
The report comprises two separate parts:part 1: Temperature needs for district heating in the paint shop for axles in building 210part 2: Energy and low temperature waste heat solutions in heating and Cooling systems for building 64 with surroundingsThe paint shop for axles in part 1 has air quality requirements in places for coating of axles. Toachieve desired air properties there are different process ventilation systems, which consist ofventilation coils for heating and Cooling, plus air humidifier. The ventilations coils for heating usedistrict heating. Today the ventilation coils use water of 100°C to achieve necessary air demands inthe coating boxes. This part of the report investigates whether the existing system would achievethe air requirements with a water temperature of 75°C instead of 100°C in the ventilation coilsduring the coldest parts of the year.
Salmonella prevalence in the poultry feed industry in Pakistan
Abstract
One of the leading causes of food borne infections in the world is due to Salmonella by con-suming poultry products including eggs and meat. According to US Food and Drug Admin-istration (2009), 2 to 4 million cases of Salmonellosis in humans occur every year only in US. Salmonella causes wide range of diseases with enteric and typhoid fever, food poisoning, di-arrhea and gastro-enteritis. Many serotypes of Salmonella do not have host specificity and cause disease in all kinds of animals and humans. Salmonella has capability to modify accord-ing to the changing environment and it can develop resistance against routine elimination practices of sanitation, chemical treatments and antibacterial drugs.
Newly established poultry industries in Pakistan are confronting various infectious diseases including Salmonellosis while in Sweden Salmonella prevalence in animal products con-sumed for humans is extremely low.
Oljetemperaturens inverkan på motoroljans degradering i lastbil
The market for heavy duty engines is constantly requiring engines that should be more andmore powerful, while still maintaining low fuel consumption. As a result of increasing enginepower, the engine and coolant temperature increases as well due to insufficient Coolingperformance (because of design issues, cost etc.).Also, emission legislations, both current and future, require more and more measures to betaken by engine manufacturers. One way of meeting the legislations is the use of cooled EGR(Exhaust Gas Recirculation), which also lead to increased coolant temperatures.Both these factors also naturally lead to increased engine oil temperatures, the consequencesof which are not thoroughly investigated.This thesis project aims to investigate effects of high temperatures on engine oil degradation,with focus on the greatest degradation process: oxidation. To do this several engine runs havebeen performed on a 310 hp engine with EGR to see what happens to the engine oil in a realengine when exposed to high temperatures. During the tests oil samples have been taken andanalysed for important parameters.As a complement to these engine tests some laboratory oxidation testing have also beenperformed, to be able to compare engine test data with laboratory tests.One goal of the project was to try to formulate an empirical oxidation model, which would beable to predict oil oxidation levels in an engine, given any running parameters.
Solceller som energikälla och solskydd för tält
This degree project is an investigation of solar cells and their ability to deliver electric power as well as reducing the need for Cooling. The main object of interest is a BASE-X shelter. The shelter is purchased by the Swedish Defence Materiel Administration, FMV to be used for command and camp in the new force called Nordic Battlegroup, NBG. The demand on the equipment is firstly that it should have a small weight to be easy to transport and handle and secondly to be easy to bring up fast. Therefore the choice of solar cell technology fell on thin film cells.
En studie av Uppsala stads värmeö
The urban heat island is an area restricted to a city center where the temperatureis higher than its surrounding environment. The greatest temperature difference isfound at night when the weather is calm and the sky is clear of clouds. There are twomajor causes behind this phenomena and the first one is the use of energy forheating of houses. The heat leaks through the walls of the buildings and warms upthe surrounding mass of air. The second one is the use of building material whichstore the suns radiation on daytime and releases the heat during night.
Lagring av kyla i bergrum : Undersökning av ett nedlagt oljebergrum
This thesis considers the use of an oldrock cavern as thermal energy storage.With a large system of differentchillers a model was created to find anappropriate future system. There aremainly two trajectories to take. Eitheran installation of chillers needs to bemade or the rock cavern can be used tomeet the future demand of districtCooling in Solna, Sweden. Additionallythis thesis investigates the possibleuse of different techniques to utilizethe phase change energy of water.Simulation shows that it?s possible toutilize the phase-change energy of afluid; however it?s not economicallyfeasible due to the thermodynamiceffects on the Carnot cycle.
Torkning av flis med restvärme : Metoder för att sänka återledningstemperaturen
The purpose of this study has been to evaluate whether a Low temperature bio-mass dryer could be integrated with the local district heating system in Malå. The aim is to increase the thermal efficiency of the cogeneration plant in Malå, by lowering the temperature of the Cooling medium. Another benefit that comes from this is improved combustion efficiency at the power plant, since drying the fuel causes an Increase of the heating value.Simulations has been made in Excel, and with use of linear regression, to find out if it is profitable. Data for this purpose has been supplied by the power company Skellefteåkraft and furthermore SMHI.The result of the Calculations shows that a very efficient bio-mass dryer is needed, if yield of investments should be made possible. An Investment of 4,27 Mkr, in a dryer, could at a such criterium return 60000 kr/year, if the price of the biomass is 190kr/MWh.
Soldriven kylning i Sverige
This thesis has been performed at the system development company Verendus System AB, together with the home care company Basic Care Unit (BCU).The thesis has consisted of developing a web based informationsystem for BCU in which they can administrate their business. At the time of writing this thesis, BCU was using a windows-application to administrate their activities, which was both costly aswell as resulting in an unnecessary burden. The aim the thesis has thus been to create a platform-independent information system that simplifies and streamlines BCUs work by being user-friendly aswell as imposing some simplifying features.The students has been developing the system by the help of a work method they themselves developed. The method consisted of working in several iterations that each had several milestones. The method resulted in the students knowing easily when each iteration was finished or not.The thesis resulted in a working platform independent prototype.
Kylvattenkemikalier i länsvattnet ifrån världshandelsflottan : En approximativ beräkningsmodell för årliga utsläpp av kylvattenkemikalier ifrån världshandelsflottan
Fartyg använder sig av stora dieselmotorer för framdrift och för att producera elektricitet ombord. Motorerna samt diverse kringsystem har behov av kylning och till detta används kemikaliebehandlat vatten i ett slutet kylsystem. Vid tömning och läckage från systemet tenderar det kemikaliebehandlade vattnet att hamna med länsvattnet. Länsvattnet genomgår en reningsprocess innan det pumpas överbord. Denna reningsprocess är inte utformad för att avskilja kemikalier och dessa tenderar att hamna i havet.
Optimerande av gasanläggning - genom värmeåtervinning och förlustreducering. Gässlösa Reningsverk
The municipality, of Gatukontoret in Local government of Borås has in the long run, a required need to look after the current heating devices (the gas production plant) in sewage treatment plant, called Gässlösa. The practical work of the examination is about, trying to find a better way to take care of the current heat recovery. That may be one way or another, rather easy to implement in the existent construction.Through the work to increase the efficiency of the gas engine, implement of some external Cooling system by heating exchange device. That gives an opportunity to heat (primary) the digester, (but even all internal public areas) with its own superfluous heating.The report shows that if the management group may invest 422 704 crown to implement a heat exchanging device, it gives more space to reduce the need to buy expensive external energy. Gatukontoret´s pay off time, for buying machines, is 20 years, with reservation to calculate with 4 percent internal interest, leads to the yearly mount of 31103 crowns.If Gässlösa increases the gas engine time in (effective) duty approximately (correspondingly) 48 hours a month the entire investment will generate a profit in January in year seven after the implementations.
Rostfritt stål till stora vattentankar utomhus : En jämförelse mellan austenitiska och rostfria stål
The austenitic stainless steel 316L has been compared to duplex stainless steels to be able to highlight a choice of material for manufacturing of spare tanks used for Cooling water at nuclear power stations on the Swedish west coast. In this report 316L and the duplex stainless steels 2205, 2304 and LDX 2404 have been compared according to corrosion resistance, strength, manufacturing aspects and prices. The steels arranged by increasing corrosion resistance: 316L < 2304 < LDX 2404 < 2205. The steels arranged by increasing strength (considering the thickness of the plates needed for construction): 316L < 2304 < LDX 2404 and 2205. The steels arranged by increasing price/tank: 2304 < LDX 2404 < 2205 < 316L.
Morgondagens effektiva fjärrvärme : En beskrivande litteraturstudie
This report is made as a literature review, focusing on the work done to increase understanding of efficiency in the categories of substations and secondary heating systems, with respect to the deviation from the theoretically possible Cooling off in the distribution network as well as the economic benefit that appear. The main purpose of a considerable part of the literature used in this report addresses the issue of identifying individual causes of reduced Cooling in district heating systems. These literature resources have been compiled and summarized as part of the report.The technology of district heating is associated with benefits such as better use of the energy in a fuel. This is the case of cogeneration plants where serial generation of electricity and thermal energy increases efficiency compared with the parallel generation where heat is generated locally and electricity is generated centrally. Serial generation thus allows for lower primary energy demand.
Energioptimering : Resteffektkylning av mellanlager för använt kärnbränsle (CLAB) Oskarshamn
This thesis is done in cooperation with SWECO Energuide in Växjö. They have been assigned by SKB in Oskarshamn to renew their electrical power supply and the ancillary processing systems in their Central provisional storage of spent nuclear fuel, CLAB. Today in the CLAB facility, the spent fuel is cooled down with water pumps, driven by asynchronous induction motors, where the water is regulated by mechanical valves to the desired flow. After the upgrade, the engines will be powered by AC drives that can control the pumps by changing the rotational speed and thus change the water's Cooling effect on the nuclear fuel. In this study, I investigated the interference AC drives causes the feeding network and how to go about averting them.
Termoelektrisk lagring i system med fjärrvärmeproduktion
With increased deployment ofintermittent renewable energy, such aswind and solar power, energy storagebecomes necessary to help reduceproduction peaks. Thermoelectric EnergyStorage is a method still in researchphase, which stores electricity in hotwater at a temperature of 120 ° C. Thisthesis aims to examine whether theThermoelectric Energy Storage would bepossible to integrate into existingpower generation such as a combined heatand power plant, and how the technologypotentially could function in theelectricity market. ThermoelectricEnergy Storage consists of a chargingprocess and a discharging process, bothoperating by the working fluid CO2. Toincrease the efficiency of theThermoelectric Energy Storage, wasteheat from the district heating networkis integrated.A model of the Thermoelectric EnergyStorage has been developed and it wascalculated by thermodynamic propertiesof the working fluid, CO2, in thevarious process steps.
Energikonsumtion hos en diskmaskin
The dishwasher is a wide spread product that occurs in many households. It saves the user time,water and energy. When using a dishwasher instead of doing dishes by hand a lot of energy issaved.The importance of lowering the energy consumption does not only come from the consumerwinnings but also from an environmental point of view. Scientists are certain that the globalwarming comes from the emission of green house gasses that is created by human consumptionof oil, gas and coal.Dishwashers today are a lot more energy efficient than older dishwashers, but there are stillmargins to lower the energy consumption. The aim with this project is to investigate thedishwasher and it?s washing cycle, noting different phases and components that contribute towaste of energy.