Sök:

Sökresultat:

58 Uppsatser om Converter - Sida 3 av 4

Problem med att få besiktningsanmärkningar åtgärdade. Felaktiga inställningar och attityder fördyrar våra byggprojekt

The use of Power Line Communication, PLC, as a communication solution for Automated Meter Reading, AMR, is popular by utilities in Sweden and other parts of the world due to demands of accurate and fast meter reading. However the use of the electrical grid as a communication medium is complex and sometimes problematic. This report handles some of the issues and problems that are important to understand when using the grid as a communications medium. Focus is mainly on investigating high frequency distortion in the Kristianstad power grid own by C4energi caused by a frequency Converter. Measurements on site are done to investigate signal damping in the grid, different configurations for the frequency Converter and signal strength of the PLC-system.

Arbetsgång för optimering av antal jord-bergsonderingar - med avseende på bergytans nivå inom ett område

The use of Power Line Communication, PLC, as a communication solution for Automated Meter Reading, AMR, is popular by utilities in Sweden and other parts of the world due to demands of accurate and fast meter reading. However the use of the electrical grid as a communication medium is complex and sometimes problematic. This report handles some of the issues and problems that are important to understand when using the grid as a communications medium. Focus is mainly on investigating high frequency distortion in the Kristianstad power grid own by C4energi caused by a frequency Converter. Measurements on site are done to investigate signal damping in the grid, different configurations for the frequency Converter and signal strength of the PLC-system.

Kollektivtrafikanalys av Frihamnen Göteborg. En studie av olika utbyggnadsscenarier och dess transportbehov vid en färdig utbyggnad av Frihamnen år 2040

The use of Power Line Communication, PLC, as a communication solution for Automated Meter Reading, AMR, is popular by utilities in Sweden and other parts of the world due to demands of accurate and fast meter reading. However the use of the electrical grid as a communication medium is complex and sometimes problematic. This report handles some of the issues and problems that are important to understand when using the grid as a communications medium. Focus is mainly on investigating high frequency distortion in the Kristianstad power grid own by C4energi caused by a frequency Converter. Measurements on site are done to investigate signal damping in the grid, different configurations for the frequency Converter and signal strength of the PLC-system.

Arbetsberedningar i syfte att öka delaktighet och tillvaratagande av kompetens bland yrkesarbetare -Utvärdering av ett nytt arbetssätt för Skanska Region Hus Göteborg

The use of Power Line Communication, PLC, as a communication solution for Automated Meter Reading, AMR, is popular by utilities in Sweden and other parts of the world due to demands of accurate and fast meter reading. However the use of the electrical grid as a communication medium is complex and sometimes problematic. This report handles some of the issues and problems that are important to understand when using the grid as a communications medium. Focus is mainly on investigating high frequency distortion in the Kristianstad power grid own by C4energi caused by a frequency Converter. Measurements on site are done to investigate signal damping in the grid, different configurations for the frequency Converter and signal strength of the PLC-system.

Analog-to-Digital Converter Design for Non-Uniform Quantization

The thesis demonstrates a low-cost, low-bandwidth and low-resolution Analog-to- Digital Converter(ADC) in 0.35 um CMOS Process. A second-order Sigma-Delta modulator is used as the basis of the A/D Converter. A Semi-Uniform quantizer is used with the modulator to take advantage of input distributions that are dominated by smaller-amplitude signals e.g. Audio, Voice and Image-sensor signals. A Single-bit feedback topology is used with a multi-bit quantizer in the modulator.

Modernisering av testutrustning

Rapporten beskriver arbetet med att modernisera en testutrustning för ett robotsystem. Den nya testutrustningen skulle moderniseras till att använda USB-gränssnitt istället för RS232-gränssnitt för kommunikation mellan dator och den övriga hårdvaran. Arbetet börjar med kravspecifikation och slutar med en fungerande produkt. I det innefattas en kortare förklaring av USB-gränssnittet och dess skillnader från RS232-gränssnittet, en utredning för att finna den bästa lösningen för att förverkliga USB-kommunikationen med utrustningen och konstruktion av elektronik för att styra signaler och spänningsmatningar till robotsystemet..

Utveckling och konstruktion av dämpare och låssystem för vågkraftverk

The division of Electricity at Uppsala University is developing a wave energy Converter(WEC) consisting of a linear generator connected to a bouy at the water surfacethrough a wire cable called the connection line.During extreme conditions, the wave power plant will experience forces up to 500kN, which lead to unnecessary wear and will ultimately cause the failure of theConverter. To prevent this there is a need for a damper.The wave energy Converter works at a maximum efficiency when the translator?sare centered with respect to the stator. Due to tidal movements the position of thetranslator can deviate. There for a mechanical divice that will compensate for this isneeded.This report describes the further development of an earlier project where a tidalwave compensator for a wave energy Converter of Seabased AB was developed.

Elanslutning av fartyg i hamn : en studie om förutsättningar och konsekvenser för Köpings och Västerås hamn

The purpose of this thesis is to investigate the possibilities for shore side electricity in the ports of Västerås and Köping. A technical solution to connect the vessels to the local grid is suggested and the investigation is also aiming at an understanding of how the environment is affected by the use of shore side electricity. Furthermore, the costs of shore side electricity are considered.The maximum power demand of a vessel visiting the ports today is relatively small, but the ships visiting the ports in the future might have a larger power demand. The suggested dimension for the system is 5 MW and the result shows that the shore side electricity requires the power distribution to the ports to be expanded. The most useful solution in the ports is to connect the ships with 12 kV from a connection box in a pit at the quay.The investigation of the costs shows that it is cheaper for the ships to use electricity compared to the marine fuel.

Design av PID-regulator baserad på kommersiell processormodul

The idea to develop  a platform for a PID-controller came from the need to control the temperature in  an espresso machine in a more exact way than a thermostat could perform. In discussions with Syntronic AB the idea developed into PID-control for industrial use. Syntronic AB suggested that the platform should be based on a commercially available processor module to shorten the development time. The suggestion included the use of the microcomputer Raspberry Pi, which supports USB, HDMI, memory card and Ethernet.The work began with establishing a schedule for the 10 weeks of the projects duration, and after that a system specification listing all functions, implementation and limitations was made. When the foundation of the system specification was done, a preliminary system design took shape.Because of the Raspberry Pi´s lack of Analog-to-Digital Converter, a circuit board containing Wheatstone bridges, differential amplifiers and a two channel Analog-to-Digital Converter was fabricated.

Effektiviseringspotential inom industrisektorn : Energibesparing vid frekvensstyrning av centrifugalpumpar ? en fallstudie

The project was performed at SiemensIndustry Drive Technologies with theobjective to provide actual values forthe energy savings potential withinSiemens scope of practice.In Sweden the electrical drives standfor about 30 % of the total electricityconsumption and about 60 % of theelectricity consumption within theindustry. During the pre-study phaseelectrical drives with pump applicationswere identified as large energy users.Because of this a case study at one ofSiemens customers, Stora Enso Fors wasperformed. The system that was evaluatedduring the case study was a throttledsystem with a centrifugal pump forpumping pulp.The results yielded that a saving ofover 50 % could be achieved by replacingthe throttle valve with a variable speeddrive, a frequency Converter. Thepayback period was two years and twomonths and the present value for thetotal life cycle cost of the variablespeed system was 662.566 SEK lower thanfor the throttled system. As aconsequence, Stora Enso Fors is advisedto invest in a frequency Converter forregulation of the system.The general conclusion is that a focuson system efficiency is the mostimportant factor in energy efficiencyprojects and that the system regulationmethod has a large impact on the overallsystem losses and hence its efficiency.Energy efficiency potential forthrottled systems with centrifugal pumpsis large and significant economicalsavings can be made through investmentswith short payback time..

UTVECKLING AV PROCESSORPLATTFORM

Abstract The purpose of this project is to develop a modular processor card which is intended to work as a platform for Kitron Development Karlskoga. The modular processor card is meant to be used as a control system in development projects, mainly in medical and industrial products. The processor card will consist of a central unit with the basic functions for a control system. Furthermore there will be complete modules with machine commodity and programming, to pick exactly the necessary functions for a specific application. With consideration to the specification of the development and the main unit, I chose an adequate microprocessor (AT90CAN32) as core and interface circuits to stated border areas. The construction is first completed in the program MultiSim and then remade in the program OrCAD Capture. The programming language C was used in the software model.

Konstruktion av förstärkare och insamplingssteg till en PSAADC i 0.25 um CMOS

The aim and goal of this work has been to design and implement a voltage reference network for a 12-bit PSAADC, Parallell Successive Analog to Digital Converter. A chip containing the design has been sent away for fabrication. Because of the long processing time, no measurement data are presented. The main specifications for the voltage reference generator is to generate stable reference voltages with low noise and a good PSRR. Efforts has also been made to minimize the power consumption..

Design av slutsteg med digital PWM-teknik för gitarr

Softube has developed DSP-card and software for simulation of the sound of old tube amplifiers. The purpose with this thesis is to design a compact amplifier with high power to function together with the DSP-card and build a unit that can replace several other guitar amplifiers. The advantages with that kind of solution could be that it would be cheaper, easier to carry and easier to stor than the real amplifiers. The amplifier that has been designed is of class D type with digital PWM modulator. There is several types of amplifier modules on the market that use analog input signal, but if one of them would be used a D-A Converter is needed on the DSP card.

Design av Digital Multimeter-modul för inbyggt testsystem

The thesis work of 15 credits has been performed to interest of Norrtälje ElektronikPartner AB (NEP) in Norrtälje. The aim of the thesis was to develop a prototype for an integrated digital multimeter, designed for one of NEP's proprietary test systems. A digital multimeter module according to NEP's requirement specification, such as physical size and accuracy should be constructed. The module should be able to measure current, voltage and resistance.The final circuit was based on the chosen analog to digital-Converter, Maxim integrated´s Max134, which is the main component of the circuit for this instrument. A circuit diagram and PCB layout were made. The result of this project is a constructed DMM board.

Beräkning av återmatad bromsenergi på Malmbanan

Energi är en resurs som måste användas effektiv för att undvika onödig negativ miljöpåverkan och utgifter. Återmatning från nedåtgående malmtåg till uppåtgående malmtåg leder till en effektivisering i energiutnyttjande. Beräkningen av den återmatade energin utgår ifrån tågets lägesenergi och förlusterna från räls, lutning, vind och kurvor. Totalt kan återmatning av energi ge en besparing på 20 % för enkelspår och 20 % respektive 21 % för dubbelspår. Dubbelspår kan ha mer trafik än enkelspår men förhållandet mellan konsumerad och återmatad energi är i princip den samma.

<- Föregående sida 3 Nästa sida ->