Sökresultat:
858 Uppsatser om Coefficient of heat transmission - Sida 2 av 58
Utvärdering av magnetiska alternativ till optisk scanning
This thesis includes an energy survey of the Herrgården pre-school, which has a modern heating- and ventilation system, and a comparison with Östers pre-school which has an older system. An energy survey of Östers pre-school has already been done by a group of three students and all the calculations and values have been collected from that survey. As of today, both pre-schools are heated thru district heating. It will be much easier to make smart and feasible energy-saving-measures by first conducting the energy survey.Herrgården pre-school in Gävle houses 81 children, therteen teachers, one cleaner and one cook. It was finished in the middle of 2009 and the staff has been very pleased with the in-door climate.
Förstärkning av bro 17-803-1 : En jämförelse av förstärkningsmetoder
AbstractThis master thesis was performed at Scania transmission department in Södertälje, where the manufacturing of gears is done. Today a large amount of manual handling is performed between the machining and the hardening process. Most of the manual handling is done at the heat treatment department. The purpose of this master thesis is to give a suggestion on how to reduce or eliminate the manual handling at the heat treatment department. The possibility to use the same packaging throughout the processes will also be investigated.
Väggjutning med självkompakterande betong : Vad påverkar gjutresultatet?
AbstractThis master thesis was performed at Scania transmission department in Södertälje, where the manufacturing of gears is done. Today a large amount of manual handling is performed between the machining and the hardening process. Most of the manual handling is done at the heat treatment department. The purpose of this master thesis is to give a suggestion on how to reduce or eliminate the manual handling at the heat treatment department. The possibility to use the same packaging throughout the processes will also be investigated.
Hantering av kugghjul : -Vägen från mjukbearbetning till hårdbearbetning
AbstractThis master thesis was performed at Scania transmission department in Södertälje, where the manufacturing of gears is done. Today a large amount of manual handling is performed between the machining and the hardening process. Most of the manual handling is done at the heat treatment department. The purpose of this master thesis is to give a suggestion on how to reduce or eliminate the manual handling at the heat treatment department. The possibility to use the same packaging throughout the processes will also be investigated.
Cellulosa : en alternativ isolering med hänsyn till brand och fukt?
AbstractThis master thesis was performed at Scania transmission department in Södertälje, where the manufacturing of gears is done. Today a large amount of manual handling is performed between the machining and the hardening process. Most of the manual handling is done at the heat treatment department. The purpose of this master thesis is to give a suggestion on how to reduce or eliminate the manual handling at the heat treatment department. The possibility to use the same packaging throughout the processes will also be investigated.
Planering och projektering för individuell mätning och debitering i flerbostadshus
The study aims to reduce energy consumption in apartment buildings where individual metering and charging of heat is applied. The aim is to develop planning and design for individual metering and charging in apartment buildings.The study is based on literature review, interviews and case study that include analysis of existing documents. Interviews were carried out with the property developer and the involved consultants who planned the apartment building Yasuragi. To investigate the differences the condominium association has noted in heat consumption between flats, the debit values of the heat were used to discern which houses that were furthest from the average consumption. On these flats there were temperature measurements and thermal photo shoots made for discriminating behavior and possible construction techniques which could be the explanation for the heat spread.Boverket shows that the consumption of heat can be reduced by 10-20% after insertion of individual metering and charging in an apartment block.
Inverkan av Kiselhalten på Värmeutvidgningskoefficienten hos Aluminiumlegeringar
The purpose of this report is to document the experiments carried out, methods used and results gained during research into how the silicon content of an aluminium alloy affects the coefficient of thermal expansion (CTE).The goal of this paper is to better understand and to find a relation between silicon content and the coefficient of thermal expansion.Experiments were carried out using carefully prepared samples of Al Si alloys (0, 7, 10 and 20% Si content). Using these alloys, the CTE could be measured using a dilatometer.Comparative analysis carried out could map the effects of silicon content on the coefficient of thermal expansion and an equation was created. Using simple graphs and the rule of mixture method, the authors were able to build a simple tool for calculating the CTE of specific aluminum silicon alloys..
Implementing a receiver in a fast data transfer system : A feasibility study
This report is an outcome of a master degree project at Linköpings University in co-operation with Micronic Laser Systems AB. The purpose with this master degree project was to investigate how to implement a receiver in a data transfer system. The system consists of several data channels, where every channel consists of three parts: driver, transmission lines and receiver. The driver send low amplitude differential signals via the transmission lines to the receiver that amplifies and converts it to a single-ended signal. The receiver has to be fast and be able to feed an output signal with high voltage swing.
Restvärmeåteranvändning från absorptionsvärmepumpar : en kartläggning av möjligheter och begränsningar vid Vattenfall Värme Uppsala Block 5
Vattenfall district Heating power plant in Uppsala produces district cooling with absorption heat pumps which leads to a large amount of waste heat that has to be cooled with evaporative cooling towers. The Environmental Court has ordered Vattenfall to survey the possibilities to recover the heat, which is the focus of this thesis.The study begins with an overview of the system, and conditions and limitations for waste heat recovery is examined. In the next step alternatives to recycle the heat is evaluated, either by direct recovering or by upgrading.First, the technical possibility of each alternative is discussed, and then the operation time and the amount of recovered heat is calculated. Those alternatives which are possible are brought further to an economic analysis.The cost of investment for each alternative constitutes the basis for a present value analysis. The results are put together in a table where the total amount of recovered heat is compared with the present value for the different alternatives.
Hållbara uppvärmningsalternativ för hotellstugorna på Grinda : En kvantitativ studie gällande hållbara uppvärmningsalternativ på en skärgårdsö
Skärgårdsstiftelsen, which is responsible for several of the archipelago islands in Stockholm, has chosen to explore the possibilities for more sustainable heating systems in buildings on the islands in collaboration with KTH. A reduction of energy use and improving the efficiency of existing heating systems are included as part of the environmental work. This report studies the island of Grinda, which is located outside the area of Vaxholm in Stockholm. The study area consists of a guesthouse consisting of a restaurant as well as conference facilities and four neighboring cottages used for overnighting. The cottages now run solely on direct electricity, both for heating and hot water.
Sammanvägda avrinningskoefficienter i rationella metoden : en jämförelse mellan idag och 1970-talet
Storm water is rain and melted snow that runs off, primarily from impervious surfaces.Future storm water management is facing the challenges of increased precipitation, asclimate changes, and increased areas of impervious surfaces due to the expansion anddensification of the cities. Impervious surfaces reduce the potential for water to infiltratein the ground leading to increased surface runoff and higher peak discharge.The runoff coefficient is closely related to the percentage of impervious surfaces andrepresents the maximum percentage of a catchment that can contribute to runoff. In thisstudy, the objective was to evaluate the weighted runoff coefficient for three differenturban types; apartment buildings, townhouses and residential areas and a comparisonbetween today and the 1970`s was made.The runoff coefficient was determined by manual mapping of the different surface typesin each area based on data in the form of orthophotos and aerial photographs. The surfacetypes that were mapped were asphalt, permeable areas, tiles, sand/gravel and roof.Tiles and sand/gravel were the most difficult surface types to map. In order to see towhat extent these categories influenced the weighted runoff coefficient a sensitivityanalysis was carried out and the runoff coefficient based on surface type was changed indifferent scenarios.The results of the sensitivity analysis showed that the surface types tiles and sand/gravelhad little impact on the weighted runoff coefficient which in mainly due to the fact thatthe percentage of these surfaces types of the total area is small.The result of the study showed that the largest change in the runoff coefficient occurredin residential areas where the increase in the percentage of impervious surfaces causedby new roofs in the form of porches and garages and from paved or tiled driveways.
Kartläggning av material flödesflaskhals i ICA butik.
In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.
Datormodellering av en värmelagrande betongväggs inverkan på det termiska klimatet i ett växthus
This report describes the building of a computer model that makes it possible to simulate the thermal climate in a greenhouse. The computer model is built on the physical theory of heat exchange that occur in a greenhouse, such as radiation and convective heat exchange. The model also includes the heat storage that is active in a greenhouse.The computer model is used to simulate the thermal climate in a greenhouse under three periods, winter, spring and summer. It also investigates which effect a concrete wall has on the thermal climate in a greenhouse. The purpose of putting a concrete wall in the greenhouse model is to investigate the possibility to store heat during the day and then use this heat when the temperature drops during the night.The result from the simulations shows that a concrete wall levels the big difference in temperature that normally occurs under a day in a greenhouse.
Värmepumpars inverkan på elkvaliten
Modern technology and fast development of heat pumps, the hunt for savings in energy consumption and the strive for environmentally friendly energy sources, convenience, and financial profit, have made heat pumps a reasonable alternative for the heating of houses.When the heat pump starts it will consume a considerable amount of current, which may result in a short-lived voltage-drop if the power grid is weak compared to the start-up current.The company Fortum Distribution which owns and administrates electrical network is interested in an investigation that deals with heat pumps affect on the quality of electricity.The purpose of this investigation is to study fast electrical fluctuations (flicker) as a result of start-up currents for single as well as multiple heat pumps on the same electrical station and from this evaluate whether there will be any problems installing heat pumps..
Värmestyrning I Handske
This rapport is result of a project. The purpose of which was to design a circuit that is used in a heat glove. The heat glove is the technical aid which provides heat inside a glove.It is specially suited for old people who have problems with cold hands because of decreased blood circulation.There already was an old circuit in the glove that gives a constant current which develops heat from battery to glove through a circuit. The temperature is between 32 and 34 degrees.The problem with the existing circuit was to regulate the temperature. There is only on/off switch and there is no way to adjust desirable value of the temperature.In order to solve the problem the old circuit was investigated.