Analys av sorptiv kylning i industri- och kontorsbyggnader

Energy efficiency is important both to reduce costs and to reduce greenhouse gas emissions in the atmosphere. Reducing costs will also help maintain business competitiveness.Scania in Södertälje is a company where the optimization of energy use is an ongoing and continual process. One area with potential to make energy and cost savings is the effectiveness of the ventilation systems in offices and industrial premises at Scania. During the summer months an increased demand for cooling occurs, leading to increased ventilation and a peak in district cooling system usage. Sorptive cooling is a technology where the supplied air is cooled by applying external heat.

Wildlife Detection Network

Traffic accidents where wild animals are involved represents between 60 and 80 percent of all reported accidents, depending on location in Sweden. In a country like Sweden, with a lot of forest, there is always risk of a collision with a wild animal. Imagine if you, as a road user, had the possibility to receive warnings when the risk of an accident according to statistics is extra high.Wildlife Detection Network is a wildlife warning system with an information service, which makes the whole concept unique. When an animal is approaching the road, it is registered by sensors, and warning lights along the road are lit to inform drivers of the potential danger. In conclusion, this is a direct warning to all drivers on the road where the system is placed.When an animal is registered by the sensors, information containing time, date, weather circumstances and coordinates are sent to a database.

Utvärdering av VAV i nybyggt kontorshus

VAV (Variable Air Volume) system has been studied in a newly constructed office-building. The goal for the study has been to evaluate how the ventilations system work in practice, if adjustments can be made to achieve an more energy efficient system and to evaluate if other alternative ventilation systems is to be preferred in the further.The degree project has been executed at Helenius Engineering Firm who is working with the environment, media systems, HVAC and energy in buildings. The building that has been studied is owned and operated by Akademiska hus.Literature studies, visits at site, inventory, review of system documentation, energy analyses, interviews, key figures, LCC, sand energy- and indoor climate simulations has been made to study the building. Where appropriate some tools from Six Sigma have also been used.How to achieve an energy efficient system and a pleasant indoor climate is studied with human health and well-being as base for the indoor climate requirements. Technical support systems such as ventilation systems have to be designed so that an acceptable indoor climate can be achieved.

Kompaktaggregat till Passivhus i Sverige

Kompaktaggregat är ett integrerat FTX- och FVP-system som används i passivhus. Vi har gjortenergiberäkningar i programmet VIP+ för att se hur kompaktaggregatet skulle kunna fungera ipassivhus i Sverige.De resultat vi har fått fram ur VIP+ visar att passivhus med ett installerat kompaktaggregat klararav att nå passivhuskraven ända upp till Skellefteå. De beräknade värdena understiger kraven förpassivhus, men en viss marginal behövs för att kraven ska nås även efter uppförandet avbyggnaden. Vi har även tolkat tekniska uppgifter på ett sätt som enligt oss har en positiv effektför passivhus på kallare orter. Därför tror vi inte att värdena för de tre nordligaste platserna ärhelt tillförlitliga.

Kompaktaggregat till Passivhus i Sverige

Kompaktaggregat är ett integrerat FTX- och FVP-system som används i passivhus. Vi har gjortenergiberäkningar i programmet VIP+ för att se hur kompaktaggregatet skulle kunna fungera ipassivhus i Sverige.De resultat vi har fått fram ur VIP+ visar att passivhus med ett installerat kompaktaggregat klararav att nå passivhuskraven ända upp till Skellefteå. De beräknade värdena understiger kraven förpassivhus, men en viss marginal behövs för att kraven ska nås även efter uppförandet avbyggnaden. Vi har även tolkat tekniska uppgifter på ett sätt som enligt oss har en positiv effektför passivhus på kallare orter. Därför tror vi inte att värdena för de tre nordligaste platserna ärhelt tillförlitliga.

"Att känna sig som något lätt fjäderaktigt" : äldre människors upplevda hälsa och vårdande som stödjer deras hälsoprocess på särskilt boende

Aim: The aim of this study was to describe intensive care nurses? experiences communicating with patients during mechanical ventilation.Methods/design: A qualitative interview study. Interviews where analyzed using descriptive content analysisSetting: Nine intensive care nurses from two different intensive care units were interviewed using a semi structured interview guide.Background: Past research has shown that patients during mechanical ventilation in the intensive care unit, feel very vulnerable and the helplessness of being unable to speak. These patients feels that they are completely dependent on the nurses and their competence. It has been shown to be very important that the patient feels included, acknowledged and respected.Results: The analyzed data resulted in a theme; through communication strive to preserve patients´ dignity and three main categories; create relationship to the patient, minimize patients´ vulnerability and don´t give up.

Påverkan på energianvändning och termisk komfort vid reglerinstabilitet

The purpose of the study is to investigate the possible effects of an unstable ventilation system and its influence on energy use and thermal comfort. The report also explores how qualified personal working with HVAC view and handles system control.In order to meet the requirements in energy efficiency and a comfortable indoor climate control regulation is a prerequisite. With optimized increased complexity of the climate systems, it becomes more challenging to control the system and the risk of unstable control increases. No previous studies about what affect an unstable system can have on energy use and thermal comfort have been found.The report is based on several tests were the controlling variable has been increased until the system becomes unstable. Two different types of unstable systems have been investigated.

Energianalys av fastighet Brynäs 12:1 : Energikartläggning med effektiviseringsåtgärder inriktning mot ventilation

Energianva?ndningen i Sverige och va?rlden fo?rva?ntas o?ka och bostads- och servicesektorn sta?r fo?r 40 % av va?rldens totala energibehov. Det a?r viktigt att energieffektivisera redan befintliga byggnader och optimera dess system da? en la?gre energianva?ndning gynnar ba?de miljo?n och ekonomin. En byggnads ventilationssystem sta?r fo?r en stor del av en fastighets energianva?ndning och det finns ofta stor potential fo?r systemet att optimeras och effektiviseras.En fastighetsa?gare vill inte ha fastigheter som sta?r outhyrda.

Passivhus i Karlstad : En jämförelse med hus byggda på traditionellt sätt

Passivhus är en vidareutveckling av ett energisnålt hus, där man genom extra tjock isolering,hög kvalitet på dörrar och fönster samt husets planlösning minimerar beroende att köpa energiför uppvärmning. Passivhus har krav på uppvärmningsbehovet samtprimärenergiförbrukningen. En princip för passivhus är att de inte ska vara krångligare ellerobekvämare att bo i än vanliga hus.Lindås Park är ett bostadsområde som består av 20 st. radhus som ligger en bit utanförGöteborg. Radhuset klarar kraven för ett passivhus, det enda värmesystem som är installeratär en eftervärmare till FTX-systemet på 900 W.De passiva hus som byggts i Sverige har gemensamt är att de ligger i södra delen av Sverigeeller nära kusten, dvs.

Klimatsimulering av ett kontorsrum : Hur de termiska stigkrafterna påverkar ventilationseffektiviteten

AbstractIn urban societies people spend more and more time indoors, which put great demands on the indoor environment. If the ventilation is to manage the removal of unwanted substances in the indoor air, a good mixing of the air is required. The question arises that, whether the buoyancy forces will counteract a good mixing of the indoor air or not?This report aims to clear up the difficulties whether you need to consider the buoyancy forces or not, when adjusting a ventilation unit. For studying the indoor mixing of the air a two dimensional model is constructed in COMSOL Multiphysics.

Stäng dörren tack : En observationsstudie om dörröppningar på operationssal

Bakgrund: Flera studier beskriver vikten av att minimera dörröppningsfrekvensen på operationssalarna. Högre frekvens av dörröppningar leder till försämrad ventilation på operationssalen, vilket i sin tur kan leda till vårdrelaterade infektioner.Syfte: Syftet med denna studie var att på en operationsavdelning observera frekvensen av dörröppningar under pågående operation, varför och av vem de öppnades.Metod: Metoden var en kvantitativ deskriptiv observationsstudie med tvärsnittsdesign. Personalen på en operationsavdelning i Mellansverige observerades under pågående operationer. Observationerna utfördes sex vardagar i januari 2013 och valdes från operationsprogrammet.Resultat och slutsats: 22 observationstillfällen observerades, 11 från vardera konventionell respektive infektionskänslig kirurgi. Studien visade att dörröppningsfrekvensen var högre vid konventionell kirurgi jämfört med infektionskänslig.

Ventilation i häststall

Dagens sporthäst lever idag under människans ansvar i stallar. I stallarna förekommer luftföroreningar, den med störst påverkan på hästen är luftburna partiklar som huvudsakligen härrör från strö och stråfoder. Föroreningarna kan orsaka skada i respirationsorganen, vilket medför att hästen får en minskad prestationsförmåga och de kan leda till allvarlig sjukdom. För att bli av med föroreningarna i stallet behövs en väl fungerande ventilation, med tillräckligt flöde, som kontinuerligt kan byta ut luften i stallet. Förståelsen för problematiken med partikulära föroreningar i stalluften är dålig, bland annat för att även starkt förorenad luft kan upplevas som frisk.

Inomhusklimat i ett statligt byggnadsminne

Statliga byggnadsminnen är byggnader som genom dess speciella kulturhistoriska värde är extra viktiga att bevara för framtiden. Att bevara, speciellt äldre byggnader, är inte alltid helt enkelt. En av utmaningarna i detta är att hålla ett lämpligt inomhusklimat i byggnaden för att förhindra en allt för snabb nedbrytningsprocess av material. Det finns tre lämpliga metoder för styrning av inomhusklimatet; Skyddsvärme, avfuktning samt styrd ventilation. Beroende på vad den byggnad eller det rum som studeras skall användas till och hur de unika förutsättningarna ser ut just där kan olika metoder vara olika lämpliga.

Felisolering av hytt- och chassikomponenter på tunga fordon

This master of science thesis is focusing on how the fault handling on hardware connected toa control unit on a Scania vehicle is working. To the hardware counts buttons levers, sensorsand CAN. The work has been concentrated upon how the fault handling is working and if it ispossible to find any new fault modes.The control unit that has been studied is called the Coordinator and is the core in Scanias threenetworks of control units. The Coordinators work is to transmit messages between the threenetworks and to process signals from buttons, levers and sensors. The values is then usedinternally or is sent to other control units on the CAN networks.

Uppnå användaracceptans genom interaktionsdesign : med CRM-system som applikationsomåde

The purpose of the study was to investigate the use and losses of energy in an existing older building. Another purpose was also to look through various options for heating systems with renewable energy in the building. The aim was to reduce the use and losses of energy. The first step was to study the related electricity bills of the building and also perform measurements and calculations of the building envelope and ventilation. The next step was to find out the possible actions for energy saving by performing measurements and calculations.