Sök:

Sökresultat:

3 Uppsatser om CLAB - Sida 1 av 1

Energioptimering : Resteffektkylning av mellanlager för använt kärnbränsle (CLAB) Oskarshamn

This thesis is done in cooperation with SWECO Energuide in Växjö. They have been assigned by SKB in Oskarshamn to renew their electrical power supply and the ancillary processing systems in their Central provisional storage of spent nuclear fuel, CLAB. Today in the CLAB facility, the spent fuel is cooled down with water pumps, driven by asynchronous induction motors, where the water is regulated by mechanical valves to the desired flow. After the upgrade, the engines will be powered by AC drives that can control the pumps by changing the rotational speed and thus change the water's cooling effect on the nuclear fuel. In this study, I investigated the interference AC drives causes the feeding network and how to go about averting them.

Förutsättningarna för ett parallellt generation IV system vid svensk nybyggnation av kärnkraft.

A new build in the Swedish nuclear power system would entail increased re-quirements for the proposed repository, which is adapted after the reactors of today. With a fast reactor, capable of burning nuclear waste, operating in parallel with the light water reactors, the increased requirements on the repository could be reduced.In this thesis, simulations of a light water reactor and a fast reactor have been performed by using the Monte Carlo code Serpent to investigate the changes in the fuel inventory. The light water reactor in the study is a boiling water reactor and the fast reactor of the type sodium-cooled fast reactor and they have been used for three different operation scenarios.By studying the fuel composition and the results from the simulations of the three scenarios conclusions can be drawn. Conclusions regarding the change of the fuel inventory and decay heat in CLAB as well as the interim storage facility and in the repository. Depending on the operation alternative the changes dif-fered significantly and especially regarding the mass of burned actinides for different fuels in the fast reactor.The lowest increase of fuel assemblies was meet when using 50 years old fuel with 20MWd/kg U burnout and 2,0 % enrichment for start up of the fast reactor and 30 years old fuel assemblies with 50MWd/kg U burnout and 4,7 % enrichment for the further operation of the reactor.The increase of the number of fuel assemblies was 3174, which is equivalent to 641tons of heavy metal.

Utmattnings- och slitageuppskatting på fjärrvärmesystem - Till följd av tryck- och temperaturförändringar

Telge Nät äger och står för driften av fjärrvärmenätet i Södertälje. Detta fjärrvärmenät innefattarbland annat ett delnät som inkluderar Scania industriområde samt bostadsområden Pershagen ochVärdsholmen. Värmen till delnätet levereras dels från Igelstaverket men även från värmeåtervinning iScaniaområdet, något som bland annat lett till en ostabilitet på delnätet i sin helhet.Syftet med detta projekt var att utreda om dessa eller andra instabiliteter på nätet bidrog till störretemperatur- eller tryckvariationer som på lång sikt kan påskynda slitaget och utmattningen påsystemet. Temperaturvariationen på nätet analyserades för de större byggnadskomplexen B006,B210 och CLAB samt för huvudledningen. Tryckvariationerna i nätet analyserades främst för B210 därsåväl hetvatten som fjärrvärme förbrukas, vilket leder till snabba regleringar av ventiler och pumpar.Därutöver genomfördes även tryckmätningar på huvudledningen för att analysera omtryckvariationerna från B210 fortplantar sig vidare samt om bytet av flödesriktningen i systemetorsakar några tryckslag.Temperaturvariationer kommer att leda till ökad axiell påfrestning på systemet och kommer främstatt matta ut särskilt utsatta komponenter som T-rör och andra kraftiga rörböjar.