Kartläggning av utredningsprocessen vid Arbetsförmedlingen Rehabilitering i Sverige : en pilotstudie

The Swedish National Labour Market Administration wishes to acquire further knowledge about how the evaluation process of vocational rehabilitation at the employment service operates as a part of the quality assurance of this activity. The primary task for vocational rehabilitation at the employment service is to investigate the work capacity of unemployed people, to give them increased knowledge and better understanding of their own capacity concerning work or education. The aim of this study was to survey the evaluation process of vocational rehabilitation at the employment service in Sweden. Data were collected through telephone interviews with 15 occupational therapists employed at the employment service, who were working with vocational rehabilitation. The result shows that the investigation of work capacity can take place in different environments and that the space of time for an investigation can vary.

Uppgradering av biogas i systemperspektiv med avseende på miljöpåverkan och kostnader

Swedish biogas is currently produced mainly by anaerobic digestion of sewage sludgeat sewage treatment plants, landfills and anaerobic digestion of household or industrialwaste. Also cattle ma-nure from farms can be used to produce biogas. Upgradingbiogas represents an increase in methane concentration from about 65 % to about 97%. In addition, particles and contaminants must be sepa-rated from the upgradedbiogas. There are various methods for upgrading and this report compares sixdifferent methods with respect to environment and economy: water scrubber,Biosling, cryo technology, chemical absorption, Pressure Swing Adsorption (PSA) andmembrane separation.According to the used ORWARE model, chemical adsorption with amine has the leastenvironmen-tal impact (methane emissions) and the lowest costs.

Avbördningskapacitet för Traryd kraftverk: en modellstudie vid dimensionerande flöde

Sydkraft Vattenkraft AB owns and operates the Traryd hydropower plant, located in the river Lagan in the southern part of Sweden. The gravity dam is classed according to RIDAS guidelines (Hydropower Industry Dam Safety Guidelines) as a class 1B dam. This means that the dam must discharge a class 1-flow which has a return period of 10 000 years. The inflow into the dam has been calculated in an earlier report to 495 m3/s, with a waterline at an elevation of 126, 3 meters above sea level. The gravity dam has a discharge system with two rectangular weirs, which results in a smaller discharge than the necessary 495 m3/s.

Kapacitetsberäkningsmodell för materialhanteringsflödet på Ericsson i Kumla

Ericsson?s factory in Kumla, Modules Kumla, became a hub for radio modules and micro base stations, which enables mobile communication through radio base stations, in 2004. Because of this the factory focuses more on the logistics operations. This has led to a need to be able to plan the capacity for the materials handling system. This master thesis has therefore been performed at Modules Kumla to develop a capacity calculation model for the material handling flow during the autumn of 2005.The work has contained a mapping of the material handling flow regarding to which activities was performed and how much time they consumed.

Friidrottsungdomars fysiska kapacitet över tid : En retrospektiv studie av intagningstesterna vid friidrottsgymnasiet i Växjö mellan åren 1982 ? 2009

Background: Today when leisure time is spent, spontaneous sports activities decrease, due to a more comfortable way of living and physical capacity among non active adolescents decreases. There for it´s interesting to see how the physical capacity level has changed over time among young people participating in organized leisure time sports.Studies around the world show that young people standing outside organized sport activities have tended to decrease their physical activity levels over the last few decades. Less leisure time is spent doing physical activity and sometimes gets put into context with increased time spent behind the computer or inactivity.Design: A retrospective study of the test results on physical capacity between 1982 and 2009 for students applying to Växjö track and field high school. A total of 635 students (15 years old) have done 11 physical tests during the years. Five of these tests, with enough participants (at least 100) and documentation over at least 10 years, were used in this study.Results: This study shows that young track and field athletes have maintained the same physical capacity from 1982 to 2009.

Vidhäftning mellan prefabelement och pågjutningsbetong : Undersökning hur skrovligheten påverkar vidhäftningskapaciteten vid skjuvning

Self-compacting concrete has soon been around for a decade. Recently the prefabrication industry has started to use this fairly new concrete type in larger scales, mainly because of its distinctive properties.  There are still certain areas that need to be thoroughly examined, such as bond capacity. There have been very few studies regarding shear capacity due to the fact that the procedure is complicated.This report will highlight a method to examine the shear capacity of different surfaces that have been prewetted as well as non-prewetted surfaces. The surface areas follow BBK 04?s and Eurocode 2?s demand for surface roughness.  A smooth surface will be completed in order to confirm if the different shapes influence the bond strength by shear stress or not.                       The purpose of this essay is to measure the bond strength within the shear capacity as well as examine the impact it has on surface roughness and treatment for shear bond.The method used to identify the shear capacity is called L-shaped Push-Off Test.

Arbetsminneskapacitet: relation till verbalt flöde och indirekt minne för inhiberat material

Processing information in complex everyday life recruites different abilities than limited storage capacity. Working memory, the central executive and inhibition are constructs that have been used to describe this ability of adaptation. This paper investigates the connection between working memory capacity and performances in tasks closely associated to real life situations, i. e. verbal fluency tasks.

Jämförelsestudie för tre olika metoder att beräkna genomstansning i betong : Skillnader i genomstansningskapacitet för metoderna i BBK04, EK2 och BHB

Before the European construction standards were introduced in January 2011, it was mainly themethod in BBK04 that was used for calculating punching capacity in concrete structures, and in lesscommon cases the method in BHB. The method of BBK04 is easy to use and have had the samestructure since the first was published in 1979. The Concrete handbook method (BHB) where usuallyonly used when a higher punching capacity was needed and the cross-sectional height where fixed,calculations using this method entails more work, but will in return usually give a higher capacity. Italso allows the use of shear reinforcement to increase the cross-section capacity. The method ofcalculating punching shear in EC2 differs largely from the methods of BBK04 and BHB.

Planseparerad spårtrafik i Göteborg

The City of Gothenburg has an urgent need to upgrade its public transport. The capacity of its light rail transit (LRT) has reached maximum capacity within the inner city limits years ago. The construction of an underground metro will be very expensive and time consuming due to the soft clay beneath the city. The apparent need of developing another type of mass rapid transit (MRT) is urgent. An elevated metro have turned out to be a success in Greater Vancouver, but is it possible for the system to operate well in Gothenburg with its narrow streets and current land use; will its route coexist with the current LRT or will the noise disturb people too much?.

Planeringsverktyg för ABB Capacitors : Planering av körsekvens

ABB Capacitors is looking to introduce LEAN within their organization. The purpose of this research is to suggest ways to improve the production planning in order to facilitate the company?s production processes. This should be done in accordance with the LEAN concept.Today, ABB will produce two of the customers? orders at the same time.

Känsla av sammanhang på Samhall : Arbetare med nedsatt arbetsförmåga

Sense of coherence amongst employees with reduced work-capacity at Samhall.Sanela Jakupovic TrostekScientific essay in public health, 15 hp, Academy of Health and promoting Working Life, University of GävleThe aim of this study was to examine how employees at Samhall who has reduced work-capacity experienced their sense of coherence (SOC). The study includes gender, age and civil status in the analysis. The study includes 34 respondents which are divided as 20 men and 14 women. To measure SOC a quantitative method with a 29 standardized questionnaire was used.It was found that the employees felt, in general, low SOC, which means more difficult adaptation to their life situation. Noteworthy is that 70 % of the men in this study showed low SOC compared to 35,7 % of the women.One conclusion that can be drawn is that within Samhall, it showed that women had a higher SOC mean value than men which means they are more equipped to handle, understand and find meaning in their work life. Keywords: Antonovsky, Samhall, disability, work-capacity, sense of coherence (SOC).

Geotermi i Ungern : Undersökning av Ungerns energisituation inriktat på geotermi samt kapacitetsfaktorn för det största geotermiska värmeverket i Mellaneuropa.

Hungary?s share of renewable energy in 2010 was 7.9 %, and their renewable energy goal for 2020 is 14.65 %. Geothermal energy is one option that could help to achieve the goal, since Hungary has favorable bedrock, the temperature gradient is above average and thepermeability is high. Today Hungary is importing just over half of its primary energy supply. Because of political conflicts between nations Hungary wants to expand its own production of energy.

Miljö- och samhällsekonomisk analys av behandling av biologiskt avfall

Biogas is a renewable fuel that can be extracted from anaerobic digestion of many differentsubstrates, for example biological household waste. An alternative handling of the waste is tomix it with other wastes and incinerate it in a combined heat and power (CHP) plant. Thisstudy uses life cycle assessment to investigate which type of waste handling that is betterfrom an environmental point of view, anaerobic digestion with biogas production orincineration. The results are based on a case study of a biogas production plant owned by thecompany Ragn-Sells in Vänersborg. The alternative is incineration at a CHP plant inGothenburg.

Analys av internt produktflöde för ökad kapacitet

This master thesis was carried out at ELFA, one of the largest catalogue distributors of electronics in northern Europe. ELFA offers a wide selection of products such as measuring instruments, fuses and screwdrivers. The master thesis handles the possibilities of an increase in the internal flow of products. The background to this problem is ELFA?s acquisition of two new companies, which brought the product range in the warehouse from 55 000 to 80 000 products.

Rening av avloppsvatten med anaerob membranbioreaktor och omvänd osmos

This master's theses was carried out on assignment from Stockholm Vatten AB as a part of a project developing new waste water treatment techniques. The goal of the theisis has been to evaluate an anaerobic membrane bioreactor for treatment of waste water from Hammarby Sjöstad. The bioreactor has not been heated and the main interest has been to study the gas production, power consumption and the reduction of organic matter and nutrients.The system has been completed with a reverse osmosis unit and a total of four batch runs have been made with good results. The use of reverse osmosis allows nutrient in the waste water to be reintroduced into circulation as the reverse osmosis concentrate can be used as crop nutrient.The membrane unit is of VSEP ("Vibratory Shear Enhanced Processing") type and an extensive membrane test has been conducted. This so called L-test helped determine the most suitable type of membrane for the system to allow a higher ±ux and thus lower power consumption.